Ford Motor Company
1200 Sawgrass Corporate Pkwy, 33323, Sunrise, FL, United States
Visit website- Accredited standards
- 8
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 8 standard numbers and the 8 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fields
ISO 11452-9Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 9: Portable transmitters
ISO 11452-11Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 11: Reverberation chamber
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
ISO/IEC 17025:2017; ISO 10605; CISPR 25; ISO 11452-2; ISO 11452-4; ISO 11452-8; ISO 11452-9; ISO 7637-2; ISO 16750-2; ISO 11452-11
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
2 lines
ISO/IEC 17025
Active6143.01
The scope document we hold says it is valid until 2027-04-30.
Accredited scope, certificate 6143.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ISO 10605; CISPR 25; ISO 11452-2; ISO 11452-4; ISO 11452-8; ISO 11452-9; ISO 7637-2; ISO 16750-2; ISO 11452-11 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
FORD MOTOR COMPANY
Sunrise, FL
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 25th day of March 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 6143.01
Valid to April 30, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Element Materials Technology - MelbourneMelbourne, FL · ~215 kmA2LAShares 1 accredited test methodISO 10605
- HV TECHNOLOGIESManassas, VA · ~1,424 kmA2LAShares 1 accredited test methodISO 10605
- APTIV WESTFIELD TESTWestfield, IN · ~1,635 kmA2LAShares 1 accredited test methodISO 10605
- UL LLCNovi, MI · ~1,837 kmA2LAShares 1 accredited test methodISO 10605
- Radiometrics Midwest CorporationRomeoville, IL · ~1,864 kmA2LAShares 1 accredited test methodISO 10605
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.