- A2LARefreshed
- 4703.03Active
Accredited standards
17Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
IEC 60598 series
IEC 60598-1Luminaires - Part 1: General requirements and tests
IEC 60598-1; IEC 60598-2-1; IEC 60598-2-4; IEC 60598-2-5; IEC 60598-2-2
IEC 60598-2-1Name not checked yet
IEC 60598-1; IEC 60598-2-1; IEC 60598-2-4; IEC 60598-2-5; IEC 60598-2-2
IEC 60598-2-2Name not checked yet
IEC 60598-1; IEC 60598-2-1; IEC 60598-2-4; IEC 60598-2-5; IEC 60598-2-2
IEC 60598-2-4Name not checked yet
IEC 60598-1; IEC 60598-2-1; IEC 60598-2-4; IEC 60598-2-5; IEC 60598-2-2
IEC 60598-2-5Name not checked yet
IEC 60598-1; IEC 60598-2-1; IEC 60598-2-4; IEC 60598-2-5; IEC 60598-2-2
IEC 61000 series
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-2; IEC 61000-3-3; IEC 61000-4-2; IEC 61000-4-5; IEC 61000-4-11
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-3-2; IEC 61000-3-3; IEC 61000-4-2; IEC 61000-4-5; IEC 61000-4-11
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-3-2; IEC 61000-3-3; IEC 61000-4-2; IEC 61000-4-5; IEC 61000-4-11
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-3-2; IEC 61000-3-3; IEC 61000-4-2; IEC 61000-4-5; IEC 61000-4-11
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-3-2; IEC 61000-3-3; IEC 61000-4-2; IEC 61000-4-5; IEC 61000-4-11
IEC
IEC 61547Equipment for general lighting purposes - EMC immunity requirementsCertificate says EN 61547. Probably the same standard; not checked against the EN document.
IEC 61547; IEC 61347-1; IEC 61347-2-13; IEC 61347-2-11; IEC 62031
IEC 62031Name not checked yet
IEC 61547; IEC 61347-1; IEC 61347-2-13; IEC 61347-2-11; IEC 62031
IEC 62301Name not checked yet
ISO/IEC 17025:2017; IEC 17025; IEC 62301; ANSI C78; ANSI C62
IEC 62301; ANSI C78; ANSI C82; ANSI C62; ANSI/UL 153
IEC 61347 series
IEC 61347-1Name not checked yet
IEC 61547; IEC 61347-1; IEC 61347-2-13; IEC 61347-2-11; IEC 62031
IEC 61347-2-11Name not checked yet
IEC 61547; IEC 61347-1; IEC 61347-2-13; IEC 61347-2-11; IEC 62031
IEC 61347-2-13Name not checked yet
IEC 61547; IEC 61347-1; IEC 61347-2-13; IEC 61347-2-11; IEC 62031
Other standards
ANSI C63Name not checked yet
ANSI C63
Scope as published by A2LA
7 lines
ISO/IEC 17025
Active4703.03
The scope document we hold says it is valid until 2027-03-31.
Accredited scope, certificate 4703.03
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | electrical | ISO/IEC 17025:2017; IEC 17025; IEC 62301; ANSI C78; ANSI C62 | Lamps | - |
| 2 | electrical | IEC 62301; ANSI C78; ANSI C82; ANSI C62; ANSI/UL 153 | - | - |
| 3 | Electrical Testing | IEC 61547; IEC 61347-1; IEC 61347-2-13; IEC 61347-2-11; IEC 62031 | Electronic | - |
| 4 | electrical | IEC 60598-1; IEC 60598-2-1; IEC 60598-2-4; IEC 60598-2-5; IEC 60598-2-2 | Air | - |
| 5 | Electrical Testing | IEC 61000-3-2; IEC 61000-3-3; IEC 61000-4-2; IEC 61000-4-5; IEC 61000-4-11 | - | to 40 GHz |
| 6 | electrical | ANSI C63 | - | to 40000 MHz |
| 7 | Dimensional Metrology | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025 | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Labs with overlapping accredited scope in China
- BTL Inc. (Dongguan)Dongguan, GuangdongA2LAShares 3 accredited methods and materialsANSI C63AirElectronic
- AJT Testing ServicesGuangdongA2LAShares 2 accredited methods and materialsANSI C63Electronic
- Attestation of Global Compliance (Shenzhen) Co.,GuangdongA2LAShares 2 accredited test methodsANSI C63IEC 61000-3-2
- Bay Area Compliance Laboratories Corp.(Xiamen)XiaMenA2LAShares 2 accredited test methodsANSI C63IEC 61000-3-2
- BTF Testing Lab (Shenzhen) Co.,Shenzhen, GuangdongA2LAShares 2 accredited methods and materialsANSI C63Electronic
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.