United States

ACR Technical Services

710 Industrial Park Drive, 23608, Newport News, VA, United States

Visit website
A2LA 2171.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
37
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 37 scope lines.

A2LA certificate 2171.01 · 37 lines

LineMethodMatrixRange
1ISO 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540--
2-Steel
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 2 of 36 Parameter/Equipment Range CMC2, 6, 8 (±) Comments Conductivity – Measuring Equipment Liquid ~1 µS/cm ~10 µS/cm ~100 µS/cm ~1000 µS/cm ~1413 µS/cm ~10 000 µS/cm ~100 000 µS/cm 0.43 µS/cm 0.69 µS/cm 4.2 µS/cm 29 µS/cm 31 µS/cm 230 µS/cm 2100 µS/cm Conductivity solutions Gas Detection Equipment C 3H8 CH 4 CO O 2 H 2S 0.7 % 2.5 % 0.005 % 0.01 % 20.9 % 0.0016 % 0.0025 % 2.1 % 2.1 % 2.6 % 1.6 % 1.1 % 7.6 % 5.1 % Calibration gases: Propane Methane Carbon monoxide Oxygen Hydrogen sulfide III. Dimensional Parameter/Equipment Range CMC 2, 6 (±) Comments Dial Indicators 3, 7 Up to 1 in 170 µin Universal calibrator Dial Indicator Calibrator Up to 2 in 25 µin Gage blocks & electronic height gage Rulers – Tape Measures Up to 24 in (24 to 48) in Up to 360 in 0.017 in 0.022 in 0.015 % + 0.019 in Steel rule
See scope document
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 3 of 36 Parameter/Equipment Range CMC2, 5, 6 (±) Comments Coating Thickness Gauges Up to 10 mils Up to 100 mils 0.074 mils + 0.66 % 0.13 mils + 0.13 % Coating thickness shims Coating Thickness Shims Up to 1000 mils Up to 25 mm 0.057 mils + 0.0093 % 1.4 µm + 0.0093 % Micrometer Feeler Gauges Up to 0.125 in 94 µin Micrometer Loupes, Glass Reticles, Glass Scales, & Microscopes (0.001 to 0.22) in (0.01 to 1) mm 610 µin 7.1 µm Stage micrometer Micrometers & Calipers 3, 7 Up to 0.1 in (> 0.1 to 4) in (4 to 20) in 60 µin 53 µin (32 + 3.6L) µin Gage blocks Micrometer Rods & Length End Standards Up to 10 in (96 + 2.4L) µin Gage block & super micrometer Anvil & Spindle Flatness on Micrometers & Calipers 3 2 In Diameter: Convex Concave 5.4 µin 5.6 µin Optical flat & monochromatic light Height Gauges Up to 4 in (4 to 20) in (47 + 3.0L) µin (44 + 2.7L) µin Gage blocks Crimpers (0.011 to 0.06) in (> 0.06 to 0.25) in 270 µin (210 + 380D) µin Pin gages IV. Electrical – DC/Low Frequency Parameter/Equipment Range CMC 2, 4 (±) Comments DC Voltage 3 – Generate (0 to 220) mV 9.0 μV/V + 0.4 μV Fluke 5700A/EP w/ opt 3
4Ohm’s Law Method-See scope document
5Ohm’s Law Method-See scope document
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 6 of 36 Parameter/Equipment Range CMC2, 4, 6 (±) Comments Resistance3 – Generate (cont) Fixed Values: 100 MΩ Steps 1 GΩ Steps 10 kΩ Fixed 1 Ω Fixed 1 Ω to 100 MΩ Up to 1.1 GΩ Up to 1 GΩ Up to 10 GΩ 10 kΩ 1 Ω 1 Ω 1.9 Ω 10 Ω 19 Ω 100 Ω 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ Up to 11 Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (0.33 to 1.1) kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (0.33 to 1.1) MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (0.33 to 1.1) GΩ 0.33 % + 0.21 MΩ 0.62 % 1.2 μΩ/Ω 1.6 μΩ/Ω 80 μΩ/Ω 84 μΩ/Ω 29 μΩ/Ω 29 μΩ/Ω 15 μΩ/Ω 10 μΩ/Ω 8.9 μΩ/Ω 8.4 μΩ/Ω 6.9 μΩ/Ω 8.9 μΩ/Ω 12 μΩ/Ω 12 μΩ/Ω 19 μΩ/Ω 20 μΩ/Ω 40 μΩ/Ω 40 μΩ/Ω 140 μΩ/Ω 40 μΩ/Ω + 0.0010 Ω 30 μΩ/Ω + 0.0015 Ω 28 μΩ/Ω + 0.0014 Ω 28 μΩ/Ω + 0.0020 Ω 28 μΩ/Ω + 0.000 002 0 kΩ 28 μΩ/Ω + 0.000 020 kΩ 28 μΩ/Ω + 0.000 020 kΩ 28 μΩ/Ω + 0.000 20 kΩ 28 μΩ/Ω + 0.000 20 kΩ 32 μΩ/Ω + 0.0020 kΩ 32 μΩ/Ω + 0.000 002 0 MΩ 60 μΩ/Ω + 0.000 030 MΩ 130 μΩ/Ω + 0.000 050 MΩ 250 μΩ/Ω + 0.0025 MΩ 500 μΩ/Ω + 0.0030 MΩ 0.30 % + 0.10 MΩ 1.5 % + 0.50 MΩ IET HRRS-B-4-1 M ESI SR-104U Leeds & Northrop 4020B Fluke 5700A/EP Fluke 5520ASC600
7--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 7 of 36 Parameter/Equipment Range CMC2, 4 (±) Comments Resistance 3 – Measure Up to 10 Ω Up to 100 Ω Up to 1000 Ω Up to 10 kΩ Up to 100 kΩ Up to 1 MΩ Up to 10 MΩ Up to 100 MΩ Up to 1 GΩ 19 µΩ/Ω + 50 µΩ 15 µΩ/Ω + 500 µΩ 13 µΩ/Ω + 500 µΩ 12 µΩ/Ω + 5 mΩ 12 µΩ/Ω + 50 mΩ 18 µΩ/Ω + 2 Ω 58 µΩ/Ω + 100 Ω 0.057 % + 1 kΩ 0.57 % + 10 kΩ Agilent 3458A, opt 002 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Voltage, Fixed Points – Measure 2 mV 6 mV 20 mV 10 Hz 20 Hz 100 Hz 1 kHz 10 kHz 20 kHz 50 kHz 100 kHz 300 kHz 500 kHz 1 MHz 10 Hz 20 Hz 100 Hz 1 kHz 10 kHz 20 kHz 50 kHz 100 kHz 300 kHz 500 kHz 1 MHz 10 Hz 20 Hz 100 Hz 1 kHz 10 kHz 20 kHz 0.040 % 0.033 % 0.031 % 0.032 % 0.031 % 0.030 % 0.031 % 0.042 % 0.054 % 0.063 % 0.094 % 0.025 % 0.023 % 0.016 % 0.016 % 0.016 % 0.016 % 0.022 % 0.028 % 0.041 % 0.047 % 0.070 % 0.015 % 78 µV/V 72 µV/V 78 µV/V 61 µV/V 63 µV/V Fluke 792A
to 1000000000 Ω
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 8 of 36 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Voltage, Fixed Points – Measure (cont) 20 mV 60 mV 200 mV 600 mV 2 V 50 kHz 100 kHz 300 kHz 500 kHz 1 MHz 10 Hz 20 Hz 100 Hz 1 kHz 10 kHz 20 kHz 50 kHz 100 kHz 300 kHz 500 kHz 1 MHz 10 Hz 20 Hz 100 Hz 1 kHz 10 kHz 20 kHz 50 kHz 100 kHz 300 kHz 500 kHz 1 MHz 10 Hz 20 Hz 100 Hz 1 kHz 10 kHz 20 kHz 50 kHz 100 kHz 300 kHz 500 kHz 1 MHz 10 Hz 20 Hz 91 µV/V 0.016 % 0.022 % 0.032 % 0.053 % 85 µV/V 47 µV/V 42 µV/V 34 µV/V 36 µV/V 36 µV/V 38 µV/V 81 µV/V 0.014 % 0.022 % 0.034 % 59 µV/V 30 µV/V 30 µV/V 16 µV/V 19 µV/V 20 µV/V 31 µV/V 48 µV/V 76 µV/V 0.011 % 0.024 % 33 µV/V 23 µV/V 13 µV/V 12 µV/V 12 µV/V 12 µV/V 13 µV/V 17 µV/V 31 µV/V 36 µV/V 89 µV/V 28 µV/V 18 µV/V Fluke 792A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 9 of 36 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage, Fixed Points – Measure (cont) 2 V 6 V 20 V 60 V 100 Hz 1 kHz 10 kHz 20 kHz 50 kHz 100 kHz 300 kHz 500 kHz 1 MHz 10 Hz 20 Hz 100 Hz 1 kHz 10 kHz 20 kHz 50 kHz 100 kHz 300 kHz 500 kHz 1 MHz 10 Hz 20 Hz 100 Hz 1 kHz 10 kHz 20 kHz 50 kHz 100 kHz 300 kHz 500 kHz 1 MHz 10 Hz 20 Hz 100 Hz 1 kHz 10 kHz 20 kHz 50 kHz 100 kHz 300 kHz 11 µV/V 11 µV/V 11 µV/V 11 µV/V 11 µV/V 14 µV/V 23 µV/V 27 µV/V 44 µV/V 28 µV/V 18 µV/V 10 µV/V 10 µV/V 10 µV/V 10 µV/V 11 µV/V 11 µV/V 22 µV/V 27 µV/V 43 µV/V 30 µV/V 18 µV/V 16 µV/V 11 µV/V 11 µV/V 11 µV/V 12 µV/V 14 µV/V 23 µV/V 27 µV/V 53 µV/V 28 µV/V 19 µV/V 13 µV/V 12 µV/V 12 µV/V 12 µV/V 13 µV/V 15 µV/V 32 µV/V Fluke 792A
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 10 of 36 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Voltage, Fixed Points – Measure (cont) 200 V 600 V 1000 V 10 Hz 20 Hz 100 Hz 1 kHz 10 kHz 20 kHz 50 kHz 100 kHz 100 Hz 1 kHz 10 kHz 20 kHz 50 kHz 100 kHz 100 Hz 1 kHz 10 kHz 20 kHz 50 kHz 100 kHz 42 µV/V 20 µV/V 16 µV/V 15 µV/V 15 µV/V 15 µV/V 17 µV/V 22 µV/V 82 µV/V 43 µV/V 43 µV/V 43 µV/V 83 µV/V 170 µV/V 28 µV/V 22 µV/V 43 µV/V 43 µV/V 82 µV/V 170 µV/V Fluke 792A AC Voltage Flatness – Generate 1 mV 3 mV (10 to 30) Hz (30 to 120) Hz (0.12 to 1.2) kHz (1.2 to 120) kHz (120 to 500) kHz (0.12 to 1.2) MHz (1.2 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 30) Hz (30 to 120) Hz (0.12 to 1.2) kHz (1.2 to 120) kHz (120 to 500) kHz (0.12 to 1.2) MHz 0.062 % 0.038 % 0.038 % 0.038 % 0.046 % 0.05 % 0.05 % 0.071 % 0.23 % 0.74 % 0.038 % 0.024 % 0.024 % 0.024 % 0.033 % 0.033 % Fluke 5700A/EP/03
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 11 of 36 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Voltage Flatness – Generate (cont) 3 mV 10 mV 30 mV 100 mV 300 mV (1.2 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 30) Hz (30 to 120) Hz (0.12 to 1.2) kHz (1.2 to 120) kHz (120 to 500) kHz (0.12 to 1.2) MHz (1.2 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 30) Hz (30 to 120) Hz (0.12 to 1.2) kHz (1.2 to 120) kHz (120 to 500) kHz (0.12 to 1.2) MHz (1.2 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 30) Hz (30 to 120) Hz (0.12 to 1.2) kHz (1.2 to 120) kHz (120 to 500) kHz (0.12 to 1.2) MHz (1.2 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 30) Hz (30 to 120) Hz (0.12 to 1.2) kHz (1.2 to 120) kHz (120 to 500) kHz 0.036 % 0.061 % 0.11 % 0.19 % 0.033 % 0.021 % 0.021 % 0.021 % 0.028 % 0.029 % 0.033 % 0.058 % 0.1 % 0.18 % 0.035 % 0.02 % 0.02 % 0.02 % 0.025 % 0.029 % 0.032 % 0.057 % 0.1 % 0.18 % 0.035 % 0.02 % 0.02 % 0.02 % 0.025 % 0.029 % 0.032 % 0.057 % 0.1 % 0.18 % 0.026 % 0.018 % 0.018 % 0.018 % 0.027 % Fluke 5700A/EP/03
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 12 of 36 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Voltage Flatness – Generate (cont) 300 mV 1 V 3 V (0.12 to 1.2) MHz (1.2 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 30) Hz (30 to 120) Hz (0.12 to 1.2) kHz (1.2 to 120) kHz (120 to 500) kHz (0.12 to 1.2) MHz (1.2 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 30) Hz (30 to 120) Hz (0.12 to 1.2) kHz (1.2 to 120) kHz (120 to 500) kHz (0.12 to 1.2) MHz (1.2 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz 0.028 % 0.033 % 0.053 % 0.1 % 0.17 % 0.031 % 0.017 % 0.016 % 0.015 % 0.022 % 0.026 % 0.03 % 0.055 % 0.1 % 0.17 % 0.036 % 0.015 % 0.015 % 0.015 % 0.021 % 0.028 % 0.031 % 0.055 % 0.1 % 0.17 % Fluke 5700A/EP/03 AC Voltage3 – Generate (0.22 to 2.2) mV (2.2 to 22) mV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz 0.024 % + 4 µV 90 µV/V + 4 µV 80 µV/V + 4 µV 0.02 % + 4 µV 0.05 % + 4 µV 0.11 % + 10 µV 0.14 % + 10 µV 0.27 % + 20 µV 0.024 % + 4 µV 90 µV/V + 4 µV 80 µV/V + 4 µV 0.02 % + 4 µV Fluke 5700A/EP
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 13 of 36 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage3 – Generate (cont) (2.2 to 22) mV (22 to 220) mV (0.22 to 2.2) V (2.2 to 22) V (22 to 220) V (220 to 1100) V (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (15 to 50) Hz 50 Hz to 1 kHz 0.05 % + 4 µV 0.11 % + 10 µV 0.14 % + 10 µV 0.27 % + 20 µV 0.024 % + 4 µV 90 µV/V + 4 µV 80 µV/V + 4 µV 0.02 % + 4 µV 0.05 % + 4 µV 0.11 % + 10 µV 0.14 % + 10 µV 0.27 % + 20 µV 0.024 % + 40 μV 90 µV/V + 15 μV 50 µV/V + 8 μV 80 µV/V + 10 μV 0.011 % + 30 μV 0.042 % + 80 μV 0.1 % + 200 μV 0.17 % + 300 μV 0.024 % + 0.4 mV 90 µV/V + 0.15 mV 50 µV/V + 0.05 mV 80 µV/V + 0.1 mV 0.01 % + 0.2 mV 0.028 % + 0.6 mV 0.1 % + 2 mV 0.15 % + 3.2 mV 0.024 % + 0.4 mV 90 µV/V + 0.15 mV 50 µV/V + 0.05 mV 80 µV/V + 0.1 mV 0.015 % + 0.2 mV 0.09 % + 0.6 mV 0.44 % + 2 mV 0.8 % + 3.2 mV 0.03 % + 16 mV 0.007 % + 3.5 mV Fluke 5700A/EP
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 14 of 36 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Voltage 3 – Measure Up to 2.2 mV: Wideband (2.2 to 7) mV: Wideband (7 to 22) mV: Wideband (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (1 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (1 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (1 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz 0.17 % + 1.3 μV 0.074 % + 1.3 μV 0.042 % + 1.3 μV 0.081 % + 2 μV 0.12 % + 2.5 μV 0.23 % + 4 μV 0.24 % + 8 μV 0.35 % + 8 μV 0.07 % + 1 μV 0.17 % + 1 μV 0.3 % + 1 μV 0.7 % + 2 μV 0.085 % + 1.3 μV 0.037 % + 1.3 μV 0.021 % + 1.3 μV 0.04 % + 2 μV 0.06 % + 2.5 μV 0.12 % + 4 μV 0.13 % + 8 μV 0.23 % + 8 μV 0.07 % + 1 μV 0.1 % + 1 μV 0.17 % + 1 μV 0.37 % + 1 μV 0.029 % + 1.3 μV 0.019 % + 1.3 μV 0.011 % + 1.3 μV 0.021 % + 2 μV 0.031 % + 2.5 μV 0.081 % + 4 μV 0.089 % + 8 μV 0.17 % + 8 μV 0.07 % 0.1 % 0.17 % 0.37 % Fluke 5790A opt.003 uncertainty of wideband is for flatness relative to 1 kHz
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 15 of 36 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Voltage 3 – Measure (cont) (22 to 70) mV: Wideband (70 to 220) mV: Wideband (220 to 700) mV: Wideband 700 mV to 2.2 V: (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (1 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (1 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (1 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 20) Hz (20 to 40) Hz 0.024 % + 1.5 μV 0.012 % + 1.5 μV 0.007 % + 1.5 μV 0.013 % + 2 μV 0.026 % + 2.5 μV 0.051 % + 4 μV 0.067 % + 8 μV 0.11 % + 8 μV 0.05 % 0.1 % 0.15 % 0.35 % 0.021 % + 1.5 μV 0.009 % + 1.5 μV 0.004 % + 1.5 μV 0.007 % + 2 μV 0.016 % + 2.5 μV 0.025 % + 4 μV 0.038 % + 8 μV 0.1 % + 8 μV 0.05 % 0.1 % 0.15 % 0.35 % 0.02 % + 1.5 μV 70 μV/V + 1.5 μV 20 μV/V + 1.5 μV 50 μV/V + 2 μV 70 μV/V + 2.5 μV 0.016 % + 4 μV 0.026 % + 8 μV 0.09 % + 8 μV 0.05 % 0.1 % 0.15 % 0.35 % 0.021 % 80 µV/V Fluke 5790A opt.003 uncertainty of wideband is for flatness relative to 1 kHz
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 16 of 36 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Voltage 3 – Measure (cont) 700 mV to 2.2 V: Wideband (2.2 to 7) V: Wideband (7 to 22) V 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (1 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (1 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz 30 µV/V 50 µV/V 80 µV/V 0.018 % 0.03 % 0.1 % 0.05 % 0.1 % 0.15 % 0.35 % 0.02 % 70 µV/V 20 µV/V 50 µV/V 70 µV/V 0.016 % 0.026 % 0.09 % 0.05 % 0.1 % 0.15 % 0.35 % 0.02 % 70 µV/V 20 µV/V 50 µV/V 80 µV/V 0.019 % 0.04 % 0.12 % 0.02 % 70 µV/V 30 µV/V 50 µV/V 90 µV/V 0.02 % 0.041 % 0.12 % Fluke 5790A opt.003 uncertainty of wideband is for flatness relative to 1 kHz
17

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 17 of 36 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Voltage 3 – Measure (cont) (70 to 220) V (220 to 700) V (700 to 1000) V Up to 10 mV (10 to 100) mV (0.1 to 10) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz 0.02 % 70 µV/V 30 µV/V 70 µV/V 0.01 % 0.021 % 0.05 % 0.02 % 0.01 % 40 µV/V 0.013 % 0.05 % 0.02 % 0.01 % 0.004 % 0.013 % 0.05 % 0.03 % + 3 µV 0.02 % + 1.1 µV 0.03 % + 1.1 µV 0.1 % + 1.1 µV 0.5 % + 1.1 µV 4 % + 2 µV 1.2 % + 5 µV 70 µV/V + 4 µV 70 µV/V + 2 µV 0.014 % + 2 µV 0.03 % + 2 µV 0.08 % + 2 µV 0.3 % + 10 µV 1 % + 10 µV 70 µV/V + 0.4 mV 70 µV/V + 0.2 mV 0.014 % + 0.2 mV 0.03 % + 0.2 mV 0.08 % + 0.2 mV 0.3 % + 1 mV 1 % + 1 mV Fluke 5790A opt.003 uncertainty of wideband is for flatness relative to 1 kHz Agilent 3458A, opt 002 NOTE: synchronous sub- sampled mode
18

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 18 of 36 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Voltage3 – Measure (cont) (10 to 100) V (100 to 1000) V Up to 40 kV pk Up to 28 kVrms (1 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 60 Hz 60 Hz 0.02 % + 4 mV 0.02 % + 2 mV 0.035 % + 2 mV 0.12 % + 2 mV 0.4 % + 10 mV 1.5 % + 10 mV 0.04 % + 40 mV 0.04 % + 20 mV 0.06 % + 20 mV 0.12 % + 20 mV 0.3 % + 20 mV 5 % 5 % Agilent 3458A, opt 002 NOTE: synchronous sub- sampled mode Fluke 80K-40 AC Power3 – Generate Up to 300 W (330 to 2200) W (2200 to 20 500) W (45 to 65) Hz 0.12 % 0.11 % 0.12 % Fluke 5520A plus resistance standard AC Current 3 – Generate (0 to 220) μA (0.22 to 2.2) mA (2.2 to 22) mA (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20 Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.025 % + 16 nA 0.016 % + 10 nA 0.012 % + 8 nA 0.028 % + 12 nA 0.11 % + 65 nA 0.025 % + 40 nA 0.016 % + 35 nA 0.012 % + 35 nA 0.02 % + 110 nA 0.11 % + 650 nA 0.025 % + 400 nA 0.016 % + 350 nA 0.012 % + 350 nA 0.02 % + 550 nA 0.11 % + 5 μA Fluke 5700A/EP
19

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 19 of 36 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Current 3 – Generate (cont) (22 to 220) mA (0.22 to 2.2) A (29 to 330) μA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (1.1 to 3) A (2.2 to 22) A Clamp-On Meters – Toroidal: (10 to 16.5) A (16.5 to 150) A (150 to 1025) A Non-Toroidal: (10 to 16.5) A (16.5 to 150) A (150 to 1025) A (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 10 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 30) kHz (10 to 30) kHz (10 to 30) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz* (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 0.025 % + 4 μA 0.016 % + 3.5 μA 0.012 % + 2.5 μA 0.02 % + 3.5 μA 0.11 % + 10 μA 0.026 % + 35 μA 0.045 % + 80 μA 0.7 % + 160 μA 1.6 % + 0.4 μA 1 % + 0.6 μA 0.4 % + 4 μA 0.4 % + 200 μA 2.5 % + 5 mA 0.055 % + 1 mA 0.051 % + 1 mA 0.05 % + 1 mA 0.05 % + 1 mA 0.16A 0.18A 0.26 % + 0.11 A 0.74 % + 0.088 A 0.3 % + 0.12 A 0.8 % + 0.1 A 0.18 A 0.23 A 0.55 % + 0.27 A 1 % + 0.27 A 0.57 % + 0.95 A 0.98 % + 0.93 A Fluke 5700A/EP Fluke 5520A SC600 Fluke 5700A/EP Fluke 5520A SC600 *multiply by f in kHz Fluke 5222A Fluke 5500A coil
20--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 20 of 36 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Current 3 – Measure Up to 100 µA (0.1 to 1) mA (1 to 100) mA (0.1 to 1) A Up to 550 μA 550 μA to 5.5 mA (5.5 to 22) mA (22 to 550) mA 550 mA to 2.2 A (10 to 20) Hz (20 to 45) Hz 45 Hz to 5 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (5 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (5 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (5 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (5 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (5 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz 0.4 % + 30 nA 0.15 % + 30 nA 0.06 % + 30 nA 0.4 % + 0.2 µA 0.15 % + 0.2 µA 0.06 % + 0.2 µA 0.03 % + 0.2 µA 0.4 % + 20 µA 0.15 % + 20 µA 0.06 % + 20 µA 0.03 % + 20 µA 0.06 % + 20 µA 0.4 % + 40 µA 0.6 % + 150 µA 0.4 % + 0.2 mA 0.16 % + 0.2 mA 0.08 % + 0.2 mA 0.1 % + 0.2 mA 0.3 % + 0.2 mA 1 % + 0.4 mA 0.02 % 0.008 % 0.005 % 0.02 % 0.008 % 0.005 % 0.02 % 0.008 % 0.005 % 0.02 % 0.008 % 0.005 % 0.02 % 0.009 % 0.008 % Agilent 3458A opt. 002 Fluke 5790A w/ A40
to 100 µA
21

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 21 of 36 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Current 3 – Measure (cont) (2.2 to 11) A (11 to 20) A (5 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (5 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz 0.022 % 0.013 % 0.021 % 0.038 % 0.034 % 0.034 % Fluke 5790A w/ A40 Inductance3 – Measure 0.01 μH to 4.1 H (4.1 to 99 999) H (12 to 100) Hz 100 Hz to 1 kHz (1 to 10) kHz (10 to 100) kHz (12 to 100) Hz 100 Hz to 1 kHz (1 to 20) kHz 0.049 % 0.029 % 0.059 % 0.23 % 0.049 % 0.029 % 0.21 % GenRad 1693 Digibridge NOTE: slow measure rate, averaging, open/short Inductance3 – Generate 100 mH fixed 100 Hz 1 kHz 0.023 % 0.023 % General ratio 1482-L Capacitance3 – Measure 0.000 01 pF to 6.4 nF 6.4 nF to 99 999 μF (12 to 100) Hz 100 Hz to 1 kHz (1 to 20) kHz (12 to 100) Hz 100 Hz to 1 kHz (1 to 10) kHz (10 to 100) kHz 0.05 % 0.029 % 0.21 % 0.049 % 0.029 % 0.059 % 0.23 % GenRad 1693 Digibridge NOTE: slow measure rate, averaging, open/short Capacitance3 – Generate (0.19 to 3.3) nF (3.3 to 11) nF (11 to 110) nF (110 to 330) nF 10 Hz to 10 kHz 0.58 % + 0.01 nF 0.29 % + 0.01 nF 0.29 % + 0.1 nF 0.29 % + 0.3 nF Fluke 5520A SC600
22

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 22 of 36 Parameter/Range Frequency CMC2, 4 (±) Comments Capacitance 3 – Generate (cont) (0.33 to 1.1) µF (1.1 to 3.3) µF (3.3 to 11) µF (11 to 33) µF (33 to 110) µF (110 to 330) µF (0.33 to 1.1) mF (1.1 to 3.3) mF (3.3 to 11) mF (11 to 33) mF (33 to 110) mF 1000 pF 10 Hz to 10 kHz 1 kHz 0.29 % + 1 nF 0.29 % + 3 nF 0.29 % + 10 nF 0.46 % + 30 nF 0.52 % + 100 nF 0.52 % + 300 nF 0.52 % + 1 µF 0.52 % + 3 µF 0.52 % + 10 µF 0.87 % + 30 µF 1.3 % + 100 µF 0.64 pF of value Fluke 5520A SC600 GenRad 1404-A Phase 3 – Generate Up to 360° 1 Hz to 1 kHz (1 to 6.3) kHz (6.3 to 50) kHz (50 to 100) kHz 0.0053° 0.01° 0.017° 0.046° Clarke-Hess 5000 Phase 3 – Measure (10 to 32) mVrms 32 mV to 100 V rms (100 to 320) Vrms Up to 360°: 1:1 Resistive 1:1 Capacitive 1 Hz to 10 kHz (10 to 50) kHz 50 kHz to 10 MHz (1 to 10) Hz 10 Hz to 50 kHz 50 kHz to 10 MHz (1 to 10) Hz 10 Hz to 5 kHz 1 Hz to 1 kHz (1 to 50) kHz (1 to 50) kHz (50 to 200) kHz 0.23° 0.4° 0.7° 0.1° 0.05° 0.4° 0.23° 0.11° 0.002° 0.003° 0.003° 0.009° Krohn-Hite 6620 phase meter Clarke-Hess 5002 Agilent 3458A opt. 002
23

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 23 of 36 Parameter/Range Frequency CMC2, 4 (±) Comments Phase 3 – Measure (cont) Up to 360°: 10:1 Capacitive 100:1 Capacitive (1 to 50) kHz (50 to 200) kHz (1 to 50) kHz (50 to 200) kHz 0.003° 0.009° 0.003° 0.009° Clarke-Hess 5002 Agilent 3458A opt. 002 Distortion3 – Measure (0.3 to 100) %: < 30 V (30 to 300) V 0.1 %: < 30 V (0.001 to 100) %: 50 mV to 300 V 10 Hz to 1 MHz (1 to 3) MHz 10 Hz to 300 kHz (300 to 500) kHz (0.5 to 3) MHz (10 to 20) Hz (20 to 30) Hz 30 Hz to 300 kHz (300 to 500) kHz (0.5 to 1.2) MHz 20 Hz to 20 kHz (20 to 100) kHz 3 % of full scale 7.1 % of full scale 3 % of full scale 7.1 % of full scale 13 % of full scale 13 % of full scale 7.1 % of full scale 3 % of full scale 7.1 % of full scale 13 % of full scale 1.2 dB 2.3 dB HP 334A Agilent 8903B Oscilloscopes 3 – Square Wave Signal: 10 Hz to 10 kHz 50 Ω Impedance 1 MΩ Impedance Level Sine Wave Square Wave Signal 1 mV to 6.6 V pk – pk 1 mV to 130 Vpk - pk 5 mV to 5.5 V 50 kHz to 100 MHz 0.25 % + 40 µV 0.1 % + 40 µV 2 % + 300 µV 3.5 % + 300 µV Fluke 5520A SC600
24

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 24 of 36 Parameter/Range Frequency CMC2, 4, 6 (±) Comments Oscilloscopes 3 – (cont) Square Wave Signal Amplitude (Reference, 50 kHz) Flatness (Reference, 50 kHz) Time Markers (5-2-1 Sequence) into a 50 W Load Rise Time: 2.5 mV to 2.5 V (100 to 300) MHz (300 to 600) MHz 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz 5 s to 50 ms 20 ms to 100 ns (5 to 2) ns 10 ns (50 to 20) ns (24 to 300) ps 4 % + 300 µV 6 % + 300 µV 1.5 % + 100 µV 2 % + 100 µV 4 % + 100 µV 25 µs/s 2.5 µs/s 2.5 µs/s 2.5 µs/s 2.5 µs/s 27 % Fluke 5520A SC600 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouples 3 – Type B Type C Type E (600 to 800) °C (> 800 to 1000) °C (> 1000 to 1550) °C (> 1550 to 1820) °C (0 to 150) °C (> 150 to 650) °C (> 650 to 1000) °C (> 1000 to 1800) °C (> 1800 to 2316) °C (-250 to -100) °C (> -100 to -25) °C (> -25 to 350) °C (> 350 to 650) °C (> 650 to 1000) °C 0.44 °C 0.36 °C 0.32 °C 0.35 °C 0.32 °C 0.29 °C 0.32 °C 0.45 °C 0.70 °C 0.43 °C 0.22 °C 0.22 °C 0.21 °C 0.23 °C Fluke 5522A
25

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 25 of 36 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouples 3 – (cont) Type J Type K Type N Type R Type S Type T (-210 to -100) °C (> -100 to -25) °C (> -25 to 150) °C (> 150 to 760) °C (> 760 to 1200) °C (-210 to < 0) °C (0 to 1200) °C (-210 to -100) °C (> -100 to -25) °C (> -25 to 120) °C (> 120 to 1000) °C (> 1000 to 1372) °C (-210 to < 0) °C (0 to 1200) °C (-200 to -100) °C (> -100 to -25) °C (> -25 to 120) °C (> 120 to 410) °C (> 410 to 1300) °C (0 to 250) °C (> 250 to 400) °C (> 400 to 1000) °C (> 1000 to 1767) °C (0 to 250) °C (> 250 to 1000) °C (> 1000 to 1400) °C (> 1400 to 1767) °C (-250 to -150) °C (> -150 to 0) °C (> 0 to 120) °C (> 120 to 400) °C 0.25 °C 0.18 °C 0.17 °C 0.21 °C 0.24 °C 0.28 °C 0.18 °C 0.31 °C 0.22 °C 0.21 °C 0.25 °C 0.36 °C 0.28 °C 0.18 °C 0.37 °C 0.26 °C 0.24 °C 0.22 °C 0.27 °C 0.48 °C 0.34 °C 0.31 °C 0.36 °C 0.41 °C 0.34 °C 0.34 °C 0.40 °C 0.51 °C 0.24 °C 0.19 °C 0.19 °C Fluke 5522A Fluke 5700A/EP & digital multimeter & ice point reference Fluke 5522A Fluke 5700A/EP & digital multimeter & ice point reference Fluke 5522A
26

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 26 of 36 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of RTD Indicating Systems 3 – Pt 385, 100 Ω PtNi 385, 120 Ω Cu 427, 10 Ω (-200 to 0) °C (> 0 to 100) °C (> 100 to 260) °C (> 260 to 300) °C (> 300 to 600) °C (> 600 to 630) °C (-80 to 100) °C (> 100 to 260) °C (-100 to 260) °C 0.04 °C 0.05 °C 0.06 °C 0.07 °C 0.08 °C 0.24 °C 0.08 °C 0.15 °C 0.34 °C Fluke 5520A SC600 V. Electrical – RF/Microwave Parameter/Range Frequency CMC 2, 4, 6 (±) Comments RF Power – Generate Sine Wave (50 Ω): 1 mV to 3 Vp-p (-56.02 to 13.52) dB (3 to 10) V p-p (13.52 to 23.98) dB (25 to 10) dB (10 to -10) dB (-10 to -60) dB (-60 to -110) dB (25 to 10) dB (10 to -10) dB (-10 to -60) dB (-60 to -110) dB 1 mW Up to 50 W 0.001 Hz to 100 kHz 100 kHz to 20 MHz 0.001 Hz to 100 kHz 100 kHz to 20 MHz 10 MHz to 2 GHz (2 to 18) GHz 50 MHz (1 to 400) MHz 0.15 dB 0.23 dB 0.19 dB 0.25 dB 1.0 dB 0.75 dB 1.0 dB 1.5 dB 1.1 dB 0.75 dB 1.3 dB 2.0 dB 0.010 mW 2.5 % HP 3325A opt 001, 002 HP 3325A opt 001, 002 HP 83630A opt 001, 008, H53 HP 436A HP 83630A & amplifier
27

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 27 of 36 Parameter/Range Frequency CMC2, 4, 6 (±) Comments RF Power – Measure 1 µW to 100 mW (-30 to +20) dB 1 µW to 100 mW (-30 to +20) dB 1 µW to 100 mW (-30 to +20) dB 1 mW Up to 50 W (100 to 300) kHz 300 kHz to 10 MHz 10 MHz to 2 GHz (2 to 4.2) GHz 10 MHz to 1 GHz (1 to 3) GHz (3 to 13) GHz (13 to 18) GHz (1 to 4) GHz (4 to 12) GHz (12 to 18) GHz (18 to 26.5) GHz 50 MHz (1 to 400) MHz 0.20 dB 0.11 dB 0.11 dB 0.12 dB 0.13 dB 0.11 dB 0.11 dB 0.11 dB 0.11 dB 0.11 dB 0.12 dB 0.14 dB 0.010 mW 2.5 % HP 436A with 8482A HP 436A with 8481A HP 436A with 8485A HP 432A, 478AH73, & 34401A HP 436A with 8482A, directional coupler, & attenuators Tuned RF Power – Measure (0 to -10) dB (-10 to -20) dB (-20 to -30) dB (-30 to -40) dB (-40 to -50) dB (-50 to -60) dB (-60 to -70) dB (-70 to -80) dB (-80 to -90) dB (-90 to -100) dB (-100 to -110) dB (-110 to -120) dB 100 kHz to 26.5 GHz 0.17 dB 0.18 dB 0.20 dB 0.23 dB 0.24 dB 0.26 dB 0.34 dB 0.35 dB 0.37 dB 0.38 dB 0.41 dB 0.53 dB HP 8902A, HP 11722A, HP 11792A Attenuation – Generate SMA, 1 dB step (1 to 11) dB SMA, 10 dB step (10 to 110) dB DC to 12.4 GHz (12.4 to 26.5) GHz DC to 12.4 GHz (12.4 to 26.5) GHz 2.1 % + 0.24 dB 2.1 % + 0.29 dB 2.3 % + 0.23 dB 2.7 % + 0.15 dB Agilent 8494H Agilent 8496H
28

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 28 of 36 Parameter/Range Frequency CMC2, 4, 6 (±) Comments Frequency Modulation – Generate Rate: 100 kHz to 8 MHz Dev: < 500 kHz peak (1 to 26.5) GHz 8.8 % Agilent 83630A Frequency Modulation – Measure Rate: 20 Hz to 10 kHz Dev: ≤ 40 kHz Rate: 50 Hz to 100 kHz Dev: ≤ 400 kHz Rate: 20 Hz to 200 kHz Dev: ≤ 400 kHz (0.25 to 10) MHz 10 MHz to 26.5 GHz 10 MHz to 26.5 GHz 0.73 % + 1 digit 3.0 % + 1 digit 4.3 % + 1 digit HP 8902A with 11793A Amplitude Modulation – Measure Rate: 150 kHz to 10 MHz Depths: (5 to 99) % Rate: 150 kHz to 10 MHz Depths: Up to 99 % Rate: (10 to 1300) MHz Depths: (5 to 99) % Rate: (10 to 1300) MHz Depths: Up to 99 % Rate: (1.3 to 18) GHz Depths: (5 to 99) % Rate: (1.3 to 18) GHz Depths: Up to 99 % 50 Hz to 10 kHz 20 Hz to 10 kHz 50 Hz to 50 kHz 20 Hz to 100 kHz 50 Hz to 50 kHz 20 Hz to 100 kHz 1.9 % + 1 digit 3.0 % + 1 digit 1.3 % + 1 digit 3.3 % + 1 digit 1.3 % + 1 digit 3.3 % + 1 digit HP 8902A with 11793A Amplitude Modulation – Generate Rate: DC to 100 kHz Depths: (5 to 99) % 10 MHz to 26.5 GHz 6.3 % Agilent 83630A
29

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 29 of 36 Parameter/Range Frequency CMC2, 4 (±) Comments Phase Modulation – Measure 150 kHz to < 10 MHz Carrier 10 MHz to 18.0 GHz Carrier 200 Hz to 10 kHz 200 Hz to 20 kHz 5.1 % + 1 digit 6.7 % + 1 digit HP 8902A with 11793A VI. Mechanical Parameter/Equipment Range CMC 2, 6, 8 (±) Comments Accelerometers Frequency Response (0.02 to 5000) pC/g (1 to 10 000) mV/g Sensitivity @ 100 Hz (10 to 100) Hz (0.1 to 2) kHz (2 to 10) kHz 100 pC/g 2.7 % 2.4 % 3.3 % 2.4 % PCB 301A11 with signal conditioner, frequency generator, DMM, & shaker Pressure & Vacuum Measure & Measuring Equipment 3, 7 – Pneumatic (30 to 100) microns (> 100 to 1000) microns (1 to 10) Torr (0.1 to 1.0) inꞏH 2O (> 1.0 to 24) inꞏH2O (0.2 to 25) psia (0.2 to 25) psig (2 to 1000) psig (1000 to 10 000) psig (> 10 000 to 12 148) psig (20 to 100) psi (> 100 to 1000) psi (> 1000 to 10 000) psi 4.3 % + 1.0 microns 6.4 % – 1.1 microns 0.63 % 0.0013 inꞏH 2O 0.012 % 0.0012 inꞏH2O 15 parts in 10 6 psia 15 parts in 106 psig 16 parts in 106 psig 34 parts in 10 6 0.0037 % – 0.03 psi 0.021 % - 0.000 90 psi 0.018 % + 0.021 psi 0.0050 % + 0.80 psi Leybold CTR 90 Dwyer 1425-24 Ruska 2465-725 Ruska 2465-729 Ruska 2400-735- 00, Ruska 2402 Fluke 2700G
30-Air
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 30 of 36 Parameter/Equipment Range CMC2, 6, 8 (±) Comments Pressure & Vacuum Measure & Measuring Equipment 3, 7 – (cont) Pneumatic Hydraulic (10 to 100) psi (> 30 to 300) psi (-14.5 to 0) psi (> 0.5 to 5) psi (> 1.5 to 15) psia (> 30 to 300) psi (> 100 to 1000) psi (> 300 to 3000) psi (> 500 to 5000) psi (> 1000 to 10 000) psi (1000 to 10 000) psi (> 10 000 to 12 140) psi (> 100 to 1000) psi (> 1000 to 10 000) psi (> 100 to 1000) psi (> 300 to 3000) psi (> 500 to 5000) psi (> 1000 to 10 000) psi 0.031 % + 0.021 psi 0.024 % + 0.028 psi 0.042 psi 0.0012 psi 0.0024 psi 0.067 psi 0.28 psi 0.67 psi 1.2 psi 2.3 psi 31 parts in 10 6 0.0037 % + 0.06 psi 0.018 % + 0.021 psi 0.0050 % + 0.80 psi 0.28 psi 0.67 psi 1.2 psi 2.3 psi Crystal XP2i Druck DPI-610 & transducers Ruska 2400-735-00 Fluke 2700G Druck DPI-610 & transducers Air/Nitrogen Flow 3, 7 – Measure (0.01 to 1000) SLPM (0.0004 to 35) SCFM (3 to 10) sccm (10 to 30) sccm (30 to 100) sccm (100 to 300) sccm (0.3 to 1.0) slpm (1.0 to 3.0) slpm (3.0 to 10) slpm (10 to 30) slpm (30 to 100) slpm (100 to 300) slpm (300 to 1000) slpm (1000 to 3000) slpm 0.68 % + 0.0090 sccm 0.67 % – 0.0031 sccm 0.65 % + 0.033 sccm 0.66 % + 0.012 sccm 0.59 % + 0.000 37 slpm 0.63 % + 0.000 47 slpm 0.56 % + 0.0054 slpm 0.63 % + 0.000 91 slpm 0.65 % + 0.017 slpm 0.72 % + 0.030 slpm 0.76 % + 0.062 slpm 0.99 % – 1.7 slpm CME FCS-8A & laminar flow elements
See scope document
31

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 31 of 36 Parameter/Equipment Range CMC2, 6, 8 (±) Comments Torque 3, 7 – Measure (5 to 50) ozfꞏin (20 to 200) ozfꞏin (5 to 50) lbfꞏin (10 to 100) lbfꞏin (40 to 400) lbfꞏin (12.5 to 125) lbfꞏft (60 to 600) lbfꞏft (60 to 600) lbfꞏft (100 to 1000) lbfꞏft 0.60 % + 0.002 ozfꞏin 0.59 % + 0.012 ozfꞏin 0.59 % + 0.0035 lbfꞏin 0.59 % + 0.004 lbfꞏin 0.62 % + 0.012 lbfꞏin 0.35 % + 0.011 lbfꞏft 0.36 % + 0.014 lbfꞏft 0.60 % + 0.010 lbfꞏft 0.33 % + 0.030 lbfꞏft CDI 2000-4-02 CDI 2000-5-02 CDI 501-I-DTT CDI 1001-I-DTT CDI 4002-I-DTT CDI 2000-10-02 CDI 2000-12-02 CDI 6004-F-DTT CDI 2000-13-02 Torque – Measuring Equipment 3, 7 (8 to 336) ozfꞏin (5 to 200) lbfꞏin (15 to 260) lbfꞏft (50 to 1050) lbfꞏft 0.025 % + 0.0022 ozfꞏin 0.032 % + 0.0012 lbfꞏin 0.030 % + 0.0014 lbfꞏft 0.038 % + 0.015 lbfꞏft Torque wheel/arms, Class F weights & pan Scales & Balances3, 7 – Fixed Values: Up to 10 kg* Up to 1000 lb* (1 to 500) mg 1 g 2 g 5 g 10 g 20 g 50 g 100 g 200 g 500 g 1 kg 0.5 lb 1 lb 2 lb 5 lb 10 lb 20 lb 25 lb 50 lb 0.75 lb 5 lb 8 lb 13 lb 0.019 mg 0.042 mg 0.043 mg 0.043 mg 0.061 mg 0.090 mg 0.15 mg 0.35 mg 0.63 mg 1.5 mg 3.1 mg 0.000 13 lb 0.000 15 lb 0.000 26 lb 0.000 60 lb 0.0011 lb 0.0024 lb 0.0031 lb 0.0060 lb 0.015 lb 0.017 lb 0.017 lb 0.019 lb Class 1, 2 or 3 weights. *Fixed values. Uncertainties are per weight. Class F weights *Fixed values. Uncertainties are per weight. Weight pans
32

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) 02/10/2025 Page 32 of 36 Parameter/Equipment Range CMC2, 6, 8 (±) Comments Force – Measuring Equipment (Tension only) (1 to 10) lb (> 10 to 100) lb (> 100 to 1000 lb 0.0056 % + 0.0037 lbf 0.0063 % + 0.0037 lbf 0.011 % – 0.0010 lbf Class F weights Mass 7 – Measure (0.1 to 62) g (> 62 to 205) g (0 to 600) g (0 to 6000) g (0.2 to 1) kg (> 1 to 10) kg (> 10 to 50) kg 0.000 67 % + 0.000 081 g 0.000 45 % + 0.000 30 g 0.000 14 % + 0.0037 g 0.000 16 % + 0.025 g 0.34 % 0.035 % 0.007 % Mettler AT261 Mettler XS603S Mettler XS6002S TIF 9010A Piston Operated Volumetric Apparatus (POVA) – (10 to 100) μL (100 to 1000) μL (> 1 to 10) mL (> 10 to 100) mL (> 100 to 200) mL 0.16 % + 0.078 μL 0.21 % + 0.030 μL 0.22 % + 0.000 10 mL 0.21 % + 0.0010 mL 0.21 % Mettler AT261 & DI H2O Notes: pipettes & syringes Piston Operated Volumetric Apparatus (POVA) 3 – (1 to 10) L 0.30 % + 0.0020 L TIF 9010A & DI H2O Notes: pipettes & syringes Velocity 3, 7 – Measure (1575 to 6000) fpm 1.5 % + 2.4 fpm Alnor RVA501 Rotational Speed, RPM 3, 7 – Measuring Equipment Optical Mechanical (10 to 100 000) rpm Up to 5000 rpm 0.001 % + 0.13 rpm 0.025 % HP 3325A Quantum dynamics N-11-ECS/3A
33

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) Revised 02/10/2025 Page 33 of 36 Parameter/Equipment Range CMC2, 6, 8 (±) Comments Rotational Speed, RPM 3, 7– Measure Optical Mechanical (10 to 600) rpm (> 600 to 100 000) rpm Up to 5000 rpm 0.041 % + 0.42 RPM 0.010 % + 0.60 RPM 0.15 % + 2.0 RPM Tachometer VII. Thermodynamics Parameter/Equipment Range CMC2, 6, 8 (±) Comments Relative Humidity 3 – Measuring Equipment 11.31 % RH 33.07 % RH 75.47 % RH 97.6 % RH (10 to 40) % RH (> 40 to 97) % RH 0.61 % RH 0.62 % RH 0.97 % RH 1.5 % RH 0.97 % RH 1.3 % RH LiCl MgCl 2 NaCl K 2SO4 Vaisala MI70 with HMP-77B Relative Humidity 3 – Measure (10 to 40) % RH (> 40 to 97) % RH 0.83 % RH 1.1 % RH Vaisala MI70 with HMP-77B Temperature 3 – Measure Chambers Infrared (-80 to 150) °C (0 to 1000) °C (-196 to 0) °C 0 °C (> 0 to 232) °C (> 232 to 420) °C (> 420 to 660) °C 0 °C (> 0 to 260) °C (0 to 100) °C (> 100 to 500) °C 0.26 °C 0.089 °C 0.031 °C 0.01 °C 0.037 °C 0.048 °C 0.34 °C 0.025 °C 0.15 °C 1.1 % + 0.88 °C 1.7 % + 0.3 °C Fluke 1524 with PRT, Fluke 1524 with RTD, Fluke 5624 PRT, Fluke 5626 PRT Fluke 5627 PRT Fluke 561
34ison to PRT Fluke 9141 Notes: add 1-See scope document
35

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) Revised 02/10/2025 Page 35 of 36 IX. Time & Frequency Parameter/Equipment Range CMC2, 8 (±) Comments Frequency – Measuring Equipment 10 MHz reference (1 to 10) Hz (10 to 100) Hz (0.1 to 1) kHz (1 to 10) kHz (10 to 100) kHz (0.1 to 1) MHz (1 to 10) MHz (10 to 21) MHz 2.5 × 10 -10 Hz/Hz 1.3 × 10-2 Hz/Hz 1.3 × 10-3 Hz/Hz 1.3 × 10-4 Hz/Hz 1.3 × 10-5 Hz/Hz 1.7 × 10-6 Hz/Hz 4.9 × 10-7 Hz/Hz 2.9 × 10-7 Hz/Hz 1.7 × 10-7 Hz/Hz Agilent Z3816A Agilent 3325B/GPS Frequency – Measure 1 Hz to 225 MHz 225 MHz to 3 GHz (10 to 100) MHz (0.1 to 1) GHz (1 to 10) GHz (10 to 20) GHz 2.9 × 10 -10 Hz/Hz + 0.14 x 10-6 Hz 2.9 × 10 -9 Hz/Hz 2.4 × 10-8 Hz/Hz 2.4 × 10-9 Hz/Hz 3.5 × 10-10 Hz/Hz 2.8 × 10-10 Hz/Hz Agilent 53132A/GPS Agilent 53132A/GPS HP 5350B/GPS Timers/Stopwatches (1 to 86 400) sec (1 to 3600) sec 0.039 sec 0.50 sec Agilent 53132A/GPS Stopwatch __________________________________________________________ 1 This laboratory offers commercial calibration service and field calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC.
36

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2171.01) Revised 02/10/2025 Page 36 of 36 4 The stated measured values are determined usi ng the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction/percentage of the reading plus a fixed floor specification. 5 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches, and D is the diameter of the device in inches. 6 In the statement of CMC, percentages are percentages of reading, unless otherwise indicated. 7 The contributions from the “best existing device” are not included in the CMC claim. 8 The type of instrument or material being calib rated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 9 This scope meets A2LA’s P112 Flexible Scope Policy.
37ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

710 Industrial Park Drive, Newport News, VA, 23608, US

37.16802, -76.53560

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.