NOF Metal Coatings North America,
275 Industrial Parkway, 44024, Chardon, OH, United States
Visit website- Accredited standards
- 12
- A2LA certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 12 standard numbers and the 6 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM7
ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
ASTM B487Standard Test Method for Measurement of Metal and Oxide Coating Thickness by Microscopical Examination of Cross Section
ASTM B748
ASTM D610
ASTM D1735
ASTM D3359
ASTM G85
ISO4
ISO 1463Metallic and oxide coatings - Measurement of coating thickness - Microscopical method
ISO 1502ISO general-purpose metric screw threads - Gauges and gauging
ISO 2320Fasteners - Prevailing torque steel nuts - Functional properties
ISO 16047Fasteners - Torque/clamp force testing
Other standards1
VDA 235
RD-LP-115; ASTM D3359; GMW14829; RD-LP-112; PT-LP-153; ASTM D610; PT-LP-152; PT-QP-59; PT-QP-110; GMW14872; ASTM G85 (Annex 2); Ford L467; SAE J2334; MCNA-PT-QP-71; PT-QP-102; PT-QP-114; QA-QP-71; PT-QP-109; ASME B1.13M; GMW 16551; ISO 1502; SAE J400 (Method C); GMW14700 (Method C); PT-QP-49; PT-QP-95; ASTM D1735; GMW14729; RD-LP-132; ASTM B117; GMW3286; SAE/USCAR-1; PT-LP-158; PT-QP-38; Stellantis PF-6180; PS-50056; PS-50071; 7.G0114; Tesla: TM 7920; DIN 946; Ford WZ 100; WZ 101; WZ 102; GM 9064P
GMW3359; GMW14165; GMW16819; SAE/USCAR-10; SAE/USCAR-11; SAE J1965; ISO 16047; ISO 2320; IFI 101; VDA 235-203; VW 01129; VW 011331-1; VW 01131-2; HTES-1107; HTES-1105; HTES-1161; ASTM B487; ISO 1463; ASTM B748
Read from the A2LA scope documents we downloaded on 2026-03-14 and 2026-10-27. Register refreshed 2026-11-06.
Scope as published by A2LA
5 lines
ISO/IEC 17025
Active884.01
The scope document we hold says it is valid until 2027-11-30.
Accredited scope, certificate 884.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | RD-LP-115; ASTM D3359; GMW14829; RD-LP-112; PT-LP-153; ASTM D610; PT-LP-152; PT-QP-59; PT-QP-110; GMW14872; ASTM G85 (Annex 2); Ford L467; SAE J2334; MCNA-PT-QP-71; PT-QP-102; PT-QP-114; QA-QP-71; PT-QP-109; ASME B1.13M; GMW 16551; ISO 1502; SAE J400 (Method C); GMW14700 (Method C); PT-QP-49; PT-QP-95; ASTM D1735; GMW14729; RD-LP-132; ASTM B117; GMW3286; SAE/USCAR-1; PT-LP-158; PT-QP-38; Stellantis PF-6180; PS-50056; PS-50071; 7.G0114; Tesla: TM 7920; DIN 946; Ford WZ 100; WZ 101; WZ 102; GM 9064P | fastener coating | - |
| 2 | GMW3359; GMW14165; GMW16819; SAE/USCAR-10; SAE/USCAR-11; SAE J1965; ISO 16047; ISO 2320; IFI 101; VDA 235-203; VW 01129; VW 011331-1; VW 01131-2; HTES-1107; HTES-1105; HTES-1161; ASTM B487; ISO 1463; ASTM B748 | - | - |
| 3 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
Active884.04
The scope document we hold says it is valid until 2027-11-30.
Accredited scope, certificate 884.04
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | RD-LP-106; RD-LP-107; RD-LP-111; RD-LP-108; RD-LP-109 | - | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Chemical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
NOF METAL COATINGS NORTH AMERICA, INC
Chardon, OH
for technical competence in the field of
Chemical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 22nd day of January 2026.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 884.04
Valid to November 30, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Michigan Testing InstituteSterling Heights, MI · ~187 kmA2LAShares 1 accredited test methodASTM D3359
- Applus Reliable AnalysisMadison Heights, MI · ~188 kmA2LAShares 1 accredited test methodASTM D3359
- National Exposure TestingSylvania, OH · ~209 kmA2LAShares 1 accredited test methodASTM D3359
- Assured Testing ServicesRidgway, PA · ~210 kmA2LAShares 1 accredited test methodASTM D3359
- Technical Finishing, Inc. - TestFlint, MI · ~259 kmA2LAShares 1 accredited test methodASTM D3359
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.