FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
India

Nemko India (Test Lab) Pvt.

Plot no. 193, Sector-68, IMT Faridabad, Faridabad, 121004, India, Faridabad, India

A2LA|6933.01ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
4
Standards
16
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Nemko India (Test Lab) Pvt.?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
6933.01Active

Accredited standards

16

Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

IEC 61000 series

IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
As written on the certificate · Line 1 (A2LA 6933.01)

47 CFR, FCC Part 15 Subpart B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); CISPR 11; CISPR 14-1 (excluding disturbance power measurements); CISPR 32; ICES-GEN; ICES-001; ICES-003; AS/NZS 61000-3-2; BS EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000-3-3; BS EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000-4-2; BS EN 61000-4-2; IEC 61000-4-2; AS/NZS 61000-4-3; BS EN 61000-4-3; IEC 61000-4-3; AS/NZS 61000-4-4; BS EN 61000-4-4; IEC 61000-4-4; AS/NZS 61000-4-5; BS EN 61000-4-5; IEC 61000-4-5; AS/NZS 61000-4-6; BS EN 61000-4-6; IEC 61000-4-6; AS/NZS 61000-4-8; BS EN 61000-4-8; IEC 61000-4-8; AS/NZS 61000-4-11; BS EN 61000-4-11; IEC 61000-4-11; ISO/IEC 17025:2017

IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
As written on the certificate · Line 1 (A2LA 6933.01)

47 CFR, FCC Part 15 Subpart B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); CISPR 11; CISPR 14-1 (excluding disturbance power measurements); CISPR 32; ICES-GEN; ICES-001; ICES-003; AS/NZS 61000-3-2; BS EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000-3-3; BS EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000-4-2; BS EN 61000-4-2; IEC 61000-4-2; AS/NZS 61000-4-3; BS EN 61000-4-3; IEC 61000-4-3; AS/NZS 61000-4-4; BS EN 61000-4-4; IEC 61000-4-4; AS/NZS 61000-4-5; BS EN 61000-4-5; IEC 61000-4-5; AS/NZS 61000-4-6; BS EN 61000-4-6; IEC 61000-4-6; AS/NZS 61000-4-8; BS EN 61000-4-8; IEC 61000-4-8; AS/NZS 61000-4-11; BS EN 61000-4-11; IEC 61000-4-11; ISO/IEC 17025:2017

IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
As written on the certificate · Line 1 (A2LA 6933.01)

47 CFR, FCC Part 15 Subpart B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); CISPR 11; CISPR 14-1 (excluding disturbance power measurements); CISPR 32; ICES-GEN; ICES-001; ICES-003; AS/NZS 61000-3-2; BS EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000-3-3; BS EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000-4-2; BS EN 61000-4-2; IEC 61000-4-2; AS/NZS 61000-4-3; BS EN 61000-4-3; IEC 61000-4-3; AS/NZS 61000-4-4; BS EN 61000-4-4; IEC 61000-4-4; AS/NZS 61000-4-5; BS EN 61000-4-5; IEC 61000-4-5; AS/NZS 61000-4-6; BS EN 61000-4-6; IEC 61000-4-6; AS/NZS 61000-4-8; BS EN 61000-4-8; IEC 61000-4-8; AS/NZS 61000-4-11; BS EN 61000-4-11; IEC 61000-4-11; ISO/IEC 17025:2017

IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity testCertificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 1 (A2LA 6933.01)

47 CFR, FCC Part 15 Subpart B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); CISPR 11; CISPR 14-1 (excluding disturbance power measurements); CISPR 32; ICES-GEN; ICES-001; ICES-003; AS/NZS 61000-3-2; BS EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000-3-3; BS EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000-4-2; BS EN 61000-4-2; IEC 61000-4-2; AS/NZS 61000-4-3; BS EN 61000-4-3; IEC 61000-4-3; AS/NZS 61000-4-4; BS EN 61000-4-4; IEC 61000-4-4; AS/NZS 61000-4-5; BS EN 61000-4-5; IEC 61000-4-5; AS/NZS 61000-4-6; BS EN 61000-4-6; IEC 61000-4-6; AS/NZS 61000-4-8; BS EN 61000-4-8; IEC 61000-4-8; AS/NZS 61000-4-11; BS EN 61000-4-11; IEC 61000-4-11; ISO/IEC 17025:2017

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
As written on the certificate · Line 1 (A2LA 6933.01)

47 CFR, FCC Part 15 Subpart B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); CISPR 11; CISPR 14-1 (excluding disturbance power measurements); CISPR 32; ICES-GEN; ICES-001; ICES-003; AS/NZS 61000-3-2; BS EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000-3-3; BS EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000-4-2; BS EN 61000-4-2; IEC 61000-4-2; AS/NZS 61000-4-3; BS EN 61000-4-3; IEC 61000-4-3; AS/NZS 61000-4-4; BS EN 61000-4-4; IEC 61000-4-4; AS/NZS 61000-4-5; BS EN 61000-4-5; IEC 61000-4-5; AS/NZS 61000-4-6; BS EN 61000-4-6; IEC 61000-4-6; AS/NZS 61000-4-8; BS EN 61000-4-8; IEC 61000-4-8; AS/NZS 61000-4-11; BS EN 61000-4-11; IEC 61000-4-11; ISO/IEC 17025:2017

IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
As written on the certificate · Line 1 (A2LA 6933.01)

47 CFR, FCC Part 15 Subpart B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); CISPR 11; CISPR 14-1 (excluding disturbance power measurements); CISPR 32; ICES-GEN; ICES-001; ICES-003; AS/NZS 61000-3-2; BS EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000-3-3; BS EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000-4-2; BS EN 61000-4-2; IEC 61000-4-2; AS/NZS 61000-4-3; BS EN 61000-4-3; IEC 61000-4-3; AS/NZS 61000-4-4; BS EN 61000-4-4; IEC 61000-4-4; AS/NZS 61000-4-5; BS EN 61000-4-5; IEC 61000-4-5; AS/NZS 61000-4-6; BS EN 61000-4-6; IEC 61000-4-6; AS/NZS 61000-4-8; BS EN 61000-4-8; IEC 61000-4-8; AS/NZS 61000-4-11; BS EN 61000-4-11; IEC 61000-4-11; ISO/IEC 17025:2017

IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
As written on the certificate · Line 1 (A2LA 6933.01)

47 CFR, FCC Part 15 Subpart B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); CISPR 11; CISPR 14-1 (excluding disturbance power measurements); CISPR 32; ICES-GEN; ICES-001; ICES-003; AS/NZS 61000-3-2; BS EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000-3-3; BS EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000-4-2; BS EN 61000-4-2; IEC 61000-4-2; AS/NZS 61000-4-3; BS EN 61000-4-3; IEC 61000-4-3; AS/NZS 61000-4-4; BS EN 61000-4-4; IEC 61000-4-4; AS/NZS 61000-4-5; BS EN 61000-4-5; IEC 61000-4-5; AS/NZS 61000-4-6; BS EN 61000-4-6; IEC 61000-4-6; AS/NZS 61000-4-8; BS EN 61000-4-8; IEC 61000-4-8; AS/NZS 61000-4-11; BS EN 61000-4-11; IEC 61000-4-11; ISO/IEC 17025:2017

IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
As written on the certificate · Line 1 (A2LA 6933.01)

47 CFR, FCC Part 15 Subpart B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); CISPR 11; CISPR 14-1 (excluding disturbance power measurements); CISPR 32; ICES-GEN; ICES-001; ICES-003; AS/NZS 61000-3-2; BS EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000-3-3; BS EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000-4-2; BS EN 61000-4-2; IEC 61000-4-2; AS/NZS 61000-4-3; BS EN 61000-4-3; IEC 61000-4-3; AS/NZS 61000-4-4; BS EN 61000-4-4; IEC 61000-4-4; AS/NZS 61000-4-5; BS EN 61000-4-5; IEC 61000-4-5; AS/NZS 61000-4-6; BS EN 61000-4-6; IEC 61000-4-6; AS/NZS 61000-4-8; BS EN 61000-4-8; IEC 61000-4-8; AS/NZS 61000-4-11; BS EN 61000-4-11; IEC 61000-4-11; ISO/IEC 17025:2017

IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
As written on the certificate · Line 1 (A2LA 6933.01)

47 CFR, FCC Part 15 Subpart B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); CISPR 11; CISPR 14-1 (excluding disturbance power measurements); CISPR 32; ICES-GEN; ICES-001; ICES-003; AS/NZS 61000-3-2; BS EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000-3-3; BS EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000-4-2; BS EN 61000-4-2; IEC 61000-4-2; AS/NZS 61000-4-3; BS EN 61000-4-3; IEC 61000-4-3; AS/NZS 61000-4-4; BS EN 61000-4-4; IEC 61000-4-4; AS/NZS 61000-4-5; BS EN 61000-4-5; IEC 61000-4-5; AS/NZS 61000-4-6; BS EN 61000-4-6; IEC 61000-4-6; AS/NZS 61000-4-8; BS EN 61000-4-8; IEC 61000-4-8; AS/NZS 61000-4-11; BS EN 61000-4-11; IEC 61000-4-11; ISO/IEC 17025:2017

IEC 61000-4-12Electromagnetic Compatibility (EMC) - Part 4-12: Testing and measurement techniques - Ring wave immunity test
As written on the certificate · Line 2 (A2LA 6933.01)

AS/NZS 61000-4-29; BS EN 61000-4-29; IEC 61000-4-29; CISPR 14-2; CISPR 35; BS EN 61000-4-12; IEC/EN 61000-4-12; 47 CFR, FCC Part 15C; 47 CFR, FCC Part 15E; 47 CFR, FCC Parts 22; 24; 25; 27; 47 CFR, FCC Parts 22; 90; 95; 97 and 101; 47 CFR, FCC Part 96; RSS GEN; RSS-130; RSS-132; RSS-133; RSS-139; RSS-199; RSS-213; RSS 247; RSS 310; AS/NZ 4268; EN IEC 62311:2020; ANSI C63.10:2013; ANSI C63.10:2020; FCC KDB Publication 905462 D02 (v02); ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015

IEC 61000-4-29Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
As written on the certificate · Line 2 (A2LA 6933.01)

AS/NZS 61000-4-29; BS EN 61000-4-29; IEC 61000-4-29; CISPR 14-2; CISPR 35; BS EN 61000-4-12; IEC/EN 61000-4-12; 47 CFR, FCC Part 15C; 47 CFR, FCC Part 15E; 47 CFR, FCC Parts 22; 24; 25; 27; 47 CFR, FCC Parts 22; 90; 95; 97 and 101; 47 CFR, FCC Part 96; RSS GEN; RSS-130; RSS-132; RSS-133; RSS-139; RSS-199; RSS-213; RSS 247; RSS 310; AS/NZ 4268; EN IEC 62311:2020; ANSI C63.10:2013; ANSI C63.10:2020; FCC KDB Publication 905462 D02 (v02); ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015

Other standards

ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
As written on the certificate · Line 3 (A2LA 6933.01)

ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015; ANSI/TIA-603-E-2016; ANSI/TIA-102.CAAA-E-2016; ANSI C63.26-2015

CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
As written on the certificate · Line 1 (A2LA 6933.01)

47 CFR, FCC Part 15 Subpart B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); CISPR 11; CISPR 14-1 (excluding disturbance power measurements); CISPR 32; ICES-GEN; ICES-001; ICES-003; AS/NZS 61000-3-2; BS EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000-3-3; BS EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000-4-2; BS EN 61000-4-2; IEC 61000-4-2; AS/NZS 61000-4-3; BS EN 61000-4-3; IEC 61000-4-3; AS/NZS 61000-4-4; BS EN 61000-4-4; IEC 61000-4-4; AS/NZS 61000-4-5; BS EN 61000-4-5; IEC 61000-4-5; AS/NZS 61000-4-6; BS EN 61000-4-6; IEC 61000-4-6; AS/NZS 61000-4-8; BS EN 61000-4-8; IEC 61000-4-8; AS/NZS 61000-4-11; BS EN 61000-4-11; IEC 61000-4-11; ISO/IEC 17025:2017

CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard
As written on the certificate · Line 2 (A2LA 6933.01)

AS/NZS 61000-4-29; BS EN 61000-4-29; IEC 61000-4-29; CISPR 14-2; CISPR 35; BS EN 61000-4-12; IEC/EN 61000-4-12; 47 CFR, FCC Part 15C; 47 CFR, FCC Part 15E; 47 CFR, FCC Parts 22; 24; 25; 27; 47 CFR, FCC Parts 22; 90; 95; 97 and 101; 47 CFR, FCC Part 96; RSS GEN; RSS-130; RSS-132; RSS-133; RSS-139; RSS-199; RSS-213; RSS 247; RSS 310; AS/NZ 4268; EN IEC 62311:2020; ANSI C63.10:2013; ANSI C63.10:2020; FCC KDB Publication 905462 D02 (v02); ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015

FCC PART 15Radio Frequency Devices
As written on the certificate · Line 1 (A2LA 6933.01)

47 CFR, FCC Part 15 Subpart B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); CISPR 11; CISPR 14-1 (excluding disturbance power measurements); CISPR 32; ICES-GEN; ICES-001; ICES-003; AS/NZS 61000-3-2; BS EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000-3-3; BS EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000-4-2; BS EN 61000-4-2; IEC 61000-4-2; AS/NZS 61000-4-3; BS EN 61000-4-3; IEC 61000-4-3; AS/NZS 61000-4-4; BS EN 61000-4-4; IEC 61000-4-4; AS/NZS 61000-4-5; BS EN 61000-4-5; IEC 61000-4-5; AS/NZS 61000-4-6; BS EN 61000-4-6; IEC 61000-4-6; AS/NZS 61000-4-8; BS EN 61000-4-8; IEC 61000-4-8; AS/NZS 61000-4-11; BS EN 61000-4-11; IEC 61000-4-11; ISO/IEC 17025:2017

As written on the certificate · Line 2 (A2LA 6933.01)

AS/NZS 61000-4-29; BS EN 61000-4-29; IEC 61000-4-29; CISPR 14-2; CISPR 35; BS EN 61000-4-12; IEC/EN 61000-4-12; 47 CFR, FCC Part 15C; 47 CFR, FCC Part 15E; 47 CFR, FCC Parts 22; 24; 25; 27; 47 CFR, FCC Parts 22; 90; 95; 97 and 101; 47 CFR, FCC Part 96; RSS GEN; RSS-130; RSS-132; RSS-133; RSS-139; RSS-199; RSS-213; RSS 247; RSS 310; AS/NZ 4268; EN IEC 62311:2020; ANSI C63.10:2013; ANSI C63.10:2020; FCC KDB Publication 905462 D02 (v02); ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015

IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)Certificate says EN 62311. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 2 (A2LA 6933.01)

AS/NZS 61000-4-29; BS EN 61000-4-29; IEC 61000-4-29; CISPR 14-2; CISPR 35; BS EN 61000-4-12; IEC/EN 61000-4-12; 47 CFR, FCC Part 15C; 47 CFR, FCC Part 15E; 47 CFR, FCC Parts 22; 24; 25; 27; 47 CFR, FCC Parts 22; 90; 95; 97 and 101; 47 CFR, FCC Part 96; RSS GEN; RSS-130; RSS-132; RSS-133; RSS-139; RSS-199; RSS-213; RSS 247; RSS 310; AS/NZ 4268; EN IEC 62311:2020; ANSI C63.10:2013; ANSI C63.10:2020; FCC KDB Publication 905462 D02 (v02); ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Active

6933.01

The scope document we hold says it is valid until 2027-03-31.

View scope

Accredited scope, certificate 6933.01

LineDisciplineMethodMatrixRange
1electrical47 CFR, FCC Part 15 Subpart B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); CISPR 11; CISPR 14-1 (excluding disturbance power measurements); CISPR 32; ICES-GEN; ICES-001; ICES-003; AS/NZS 61000-3-2; BS EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000-3-3; BS EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000-4-2; BS EN 61000-4-2; IEC 61000-4-2; AS/NZS 61000-4-3; BS EN 61000-4-3; IEC 61000-4-3; AS/NZS 61000-4-4; BS EN 61000-4-4; IEC 61000-4-4; AS/NZS 61000-4-5; BS EN 61000-4-5; IEC 61000-4-5; AS/NZS 61000-4-6; BS EN 61000-4-6; IEC 61000-4-6; AS/NZS 61000-4-8; BS EN 61000-4-8; IEC 61000-4-8; AS/NZS 61000-4-11; BS EN 61000-4-11; IEC 61000-4-11; ISO/IEC 17025:2017--
2electricalAS/NZS 61000-4-29; BS EN 61000-4-29; IEC 61000-4-29; CISPR 14-2; CISPR 35; BS EN 61000-4-12; IEC/EN 61000-4-12; 47 CFR, FCC Part 15C; 47 CFR, FCC Part 15E; 47 CFR, FCC Parts 22; 24; 25; 27; 47 CFR, FCC Parts 22; 90; 95; 97 and 101; 47 CFR, FCC Part 96; RSS GEN; RSS-130; RSS-132; RSS-133; RSS-139; RSS-199; RSS-213; RSS 247; RSS 310; AS/NZ 4268; EN IEC 62311:2020; ANSI C63.10:2013; ANSI C63.10:2020; FCC KDB Publication 905462 D02 (v02); ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015-to 40 GHz
3electricalANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015; ANSI/TIA-603-E-2016; ANSI/TIA-102.CAAA-E-2016; ANSI C63.26-2015-to 40000 MHz
4electrical---

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Plot no. 193, Sector-68, IMT Faridabad, Faridabad, 121004, India, Faridabad, IN

28.40315, 77.31056

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.