J. Schmitz GmbH EMV-Kompetenzzentrum
Chiemseestraße 21, 83022, Rosenheim, Germany
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at J. Schmitz GmbH EMV-Kompetenzzentrum?
Claim this profile to keep it accurate.
Register record
- DAKKSRefreshed
- D-PL-20862-01-00Active
Accredited standards
37Our reading of the DAKKS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
IEC 61000 series
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
DIN EN IEC 61000-6-8:2022-02; IEC 61000-6-8:2020; DIN EN IEC 61000 -3-2:2019-12; IEC 61000-3-2:2018; DIN EN 61000-3-3:2023-02; IEC 61000-3-3:2013 + A1:2017 + A2:2021 + A2:2021/COR1:2022
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
DIN EN IEC 61000-6-8:2022-02; IEC 61000-6-8:2020; DIN EN IEC 61000 -3-2:2019-12; IEC 61000-3-2:2018; DIN EN 61000-3-3:2023-02; IEC 61000-3-3:2013 + A1:2017 + A2:2021 + A2:2021/COR1:2022
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
DIN EN 61000-4-2; VDE 0847-4-2:2009; IEC 61000-4-2:2008; DIN EN 61000-4-3; VDE 0847-4-3:2011; IEC 61000-4-3:2006 + A1:2007 + A2:2010; DIN EN 61000-4-4; VDE 0847-4-4:2013; IEC 61000-4-4:2012
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity testCertificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.
DIN EN 61000-4-2; VDE 0847-4-2:2009; IEC 61000-4-2:2008; DIN EN 61000-4-3; VDE 0847-4-3:2011; IEC 61000-4-3:2006 + A1:2007 + A2:2010; DIN EN 61000-4-4; VDE 0847-4-4:2013; IEC 61000-4-4:2012
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
DIN EN 61000-4-2; VDE 0847-4-2:2009; IEC 61000-4-2:2008; DIN EN 61000-4-3; VDE 0847-4-3:2011; IEC 61000-4-3:2006 + A1:2007 + A2:2010; DIN EN 61000-4-4; VDE 0847-4-4:2013; IEC 61000-4-4:2012
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
DIN EN 61000-4-5; VDE 0847-4-5:2019-03; IEC 61000-4-5:2014 + A1:2017; DIN EN 61000-4-6; VDE 0847-4-6:2014; IEC 61000-4-6:2013; DIN EN 61000-4-8:2010-11; IEC 61000-4-8:2009
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
DIN EN 61000-4-5; VDE 0847-4-5:2019-03; IEC 61000-4-5:2014 + A1:2017; DIN EN 61000-4-6; VDE 0847-4-6:2014; IEC 61000-4-6:2013; DIN EN 61000-4-8:2010-11; IEC 61000-4-8:2009
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
DIN EN 61000-4-5; VDE 0847-4-5:2019-03; IEC 61000-4-5:2014 + A1:2017; DIN EN 61000-4-6; VDE 0847-4-6:2014; IEC 61000-4-6:2013; DIN EN 61000-4-8:2010-11; IEC 61000-4-8:2009
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
DIN EN 61000-4-11; VDE 0847-4-11:2005; IEC 61000-4-11:2004; DIN EN 61000-6-1; (VDE 0839-6-1):2019-11; IEC 61000-6-1:2016; DIN EN 61000-6-2; (VDE 0839-6-2):2019-11; IEC 61000-6-2:2016
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
DIN EN 61000-4-11; VDE 0847-4-11:2005; IEC 61000-4-11:2004; DIN EN 61000-6-1; (VDE 0839-6-1):2019-11; IEC 61000-6-1:2016; DIN EN 61000-6-2; (VDE 0839-6-2):2019-11; IEC 61000-6-2:2016
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
DIN EN 61000-4-11; VDE 0847-4-11:2005; IEC 61000-4-11:2004; DIN EN 61000-6-1; (VDE 0839-6-1):2019-11; IEC 61000-6-1:2016; DIN EN 61000-6-2; (VDE 0839-6-2):2019-11; IEC 61000-6-2:2016
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environmentsCertificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.
DIN EN 61000-6-3; VDE 0839-6-3:2011; IEC 61000-6-3:2006 + A1:2010; DIN EN 61000-6-4; VDE 0839-6-4:2011; IEC 61000-6-4:2006 + A1:2010; DIN EN 61000-6-7:2015-12; IEC 61000-6-7:2014
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
DIN EN 61000-6-3; VDE 0839-6-3:2011; IEC 61000-6-3:2006 + A1:2010; DIN EN 61000-6-4; VDE 0839-6-4:2011; IEC 61000-6-4:2006 + A1:2010; DIN EN 61000-6-7:2015-12; IEC 61000-6-7:2014
IEC 61000-6-7Name not checked yet
DIN EN 61000-6-3; VDE 0839-6-3:2011; IEC 61000-6-3:2006 + A1:2010; DIN EN 61000-6-4; VDE 0839-6-4:2011; IEC 61000-6-4:2006 + A1:2010; DIN EN 61000-6-7:2015-12; IEC 61000-6-7:2014
IEC 61000-6-8Name not checked yet
DIN EN IEC 61000-6-8:2022-02; IEC 61000-6-8:2020; DIN EN IEC 61000 -3-2:2019-12; IEC 61000-3-2:2018; DIN EN 61000-3-3:2023-02; IEC 61000-3-3:2013 + A1:2017 + A2:2021 + A2:2021/COR1:2022
CISPR
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurementCertificate says EN 55011. Probably the same standard; not checked against the EN document.
DIN EN 55016-2-3:2020; CISPR 16-2-3:2016 + A1:2019; OVE EN 55011:2018-06; CISPR 11:2015, modifiziert + A1:2016; DIN EN IEC 55015 VDE 0875-15-1:2020-07
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: EmissionCertificate says IEC 55014-1. Probably the same standard; not checked against the EN document.
DIN EN 50121-3-2:2017-11; DIN EN 50121-4:2017-11; DIN EN 50130-4:2015-04; DIN EN 50155:2022-06; DIN EN IEC 55014-1:2022-12
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standardCertificate says IEC 55014-2. Probably the same standard; not checked against the EN document.
CISPR 14-1:2020; DIN EN IEC 55014-2:2022-10; CISPR 14-2:2020; DIN EN 55016-2-1:2019; CISPR 16-2-1:2014 + A1:2017
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipmentCertificate says IEC 55015. Probably the same standard; not checked against the EN document.
DIN EN 55016-2-3:2020; CISPR 16-2-3:2016 + A1:2019; OVE EN 55011:2018-06; CISPR 11:2015, modifiziert + A1:2016; DIN EN IEC 55015 VDE 0875-15-1:2020-07
CISPR 16-2-1Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurementsCertificate says EN 55016-2-1. Probably the same standard; not checked against the EN document.
CISPR 14-1:2020; DIN EN IEC 55014-2:2022-10; CISPR 14-2:2020; DIN EN 55016-2-1:2019; CISPR 16-2-1:2014 + A1:2017
CISPR 16-2-3Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurementsCertificate says EN 55016-2-3. Probably the same standard; not checked against the EN document.
DIN EN 55016-2-3:2020; CISPR 16-2-3:2016 + A1:2019; OVE EN 55011:2018-06; CISPR 11:2015, modifiziert + A1:2016; DIN EN IEC 55015 VDE 0875-15-1:2020-07
CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurementCertificate says EN 55024. Probably the same standard; not checked against the EN document.
CISPR 15:2018; DIN EN 55024:2016-05; VDE 0878-24:2016-05; DIN EN 55032; VDE 0878-32:2016; CISPR 32:2015; DIN EN 55035 (VDE 0878-35):2018-04; CISPR 35:2016, modifiziert
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirementsCertificate says EN 55032. Probably the same standard; not checked against the EN document.
CISPR 15:2018; DIN EN 55024:2016-05; VDE 0878-24:2016-05; DIN EN 55032; VDE 0878-32:2016; CISPR 32:2015; DIN EN 55035 (VDE 0878-35):2018-04; CISPR 35:2016, modifiziert
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirementsCertificate says EN 55035. Probably the same standard; not checked against the EN document.
CISPR 15:2018; DIN EN 55024:2016-05; VDE 0878-24:2016-05; DIN EN 55032; VDE 0878-32:2016; CISPR 32:2015; DIN EN 55035 (VDE 0878-35):2018-04; CISPR 35:2016, modifiziert
EN
EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
DIN EN 50121-3-2:2017-11; DIN EN 50121-4:2017-11; DIN EN 50130-4:2015-04; DIN EN 50155:2022-06; DIN EN IEC 55014-1:2022-12
EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
DIN EN 50121-3-2:2017-11; DIN EN 50121-4:2017-11; DIN EN 50130-4:2015-04; DIN EN 50155:2022-06; DIN EN IEC 55014-1:2022-12
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
DIN EN 50121-3-2:2017-11; DIN EN 50121-4:2017-11; DIN EN 50130-4:2015-04; DIN EN 50155:2022-06; DIN EN IEC 55014-1:2022-12
EN 50155Railway applications - Rolling stock - Electronic equipment
DIN EN 50121-3-2:2017-11; DIN EN 50121-4:2017-11; DIN EN 50130-4:2015-04; DIN EN 50155:2022-06; DIN EN IEC 55014-1:2022-12
ETSI
ETSI EN 301 489-1Name not checked yet
DIN EN IEC 63044-5-2; VDE 0849-44-52:2020-04; IEC 63044-5-2:2017; EN IEC 63044-5-2:2019; DIN EN IEC 63044-5-3; VDE 0849-44-53:2020-04; IEC 63044-5-3:2017; EN IEC 63044-5-3:2019; ETSI EN 301 489-1 V2.2.3 (2019-11); ETSI EN 301 489-3 V2.1.1 (2019-03)
ETSI EN 301 489-3Name not checked yet
DIN EN IEC 63044-5-2; VDE 0849-44-52:2020-04; IEC 63044-5-2:2017; EN IEC 63044-5-2:2019; DIN EN IEC 63044-5-3; VDE 0849-44-53:2020-04; IEC 63044-5-3:2017; EN IEC 63044-5-3:2019; ETSI EN 301 489-1 V2.2.3 (2019-11); ETSI EN 301 489-3 V2.1.1 (2019-03)
ETSI EN 301 489-17Name not checked yet
ETSI EN 301 489-17 V3.2.4 (2020-09)
IEC
IEC 61547Equipment for general lighting purposes - EMC immunity requirementsCertificate says EN 61547. Probably the same standard; not checked against the EN document.
DIN EN 61326-1; VDE 0842-20-1:2013; DIN EN 61326-2-3:2013-07; VDE 0843-20-2-3:2013-07; DIN EN 61326-2-5:2013-08; VDE 0843-20-2-5:2013-08; DIN EN 61547; VDE 0875-15-2:2010-03; IEC 61547:2020
IEC 63044-5-2Name not checked yet
DIN EN IEC 63044-5-2; VDE 0849-44-52:2020-04; IEC 63044-5-2:2017; EN IEC 63044-5-2:2019; DIN EN IEC 63044-5-3; VDE 0849-44-53:2020-04; IEC 63044-5-3:2017; EN IEC 63044-5-3:2019; ETSI EN 301 489-1 V2.2.3 (2019-11); ETSI EN 301 489-3 V2.1.1 (2019-03)
IEC 63044-5-3Name not checked yet
DIN EN IEC 63044-5-2; VDE 0849-44-52:2020-04; IEC 63044-5-2:2017; EN IEC 63044-5-2:2019; DIN EN IEC 63044-5-3; VDE 0849-44-53:2020-04; IEC 63044-5-3:2017; EN IEC 63044-5-3:2019; ETSI EN 301 489-1 V2.2.3 (2019-11); ETSI EN 301 489-3 V2.1.1 (2019-03)
IEC 61326 series
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
DIN EN 61326-1; VDE 0842-20-1:2013; DIN EN 61326-2-3:2013-07; VDE 0843-20-2-3:2013-07; DIN EN 61326-2-5:2013-08; VDE 0843-20-2-5:2013-08; DIN EN 61547; VDE 0875-15-2:2010-03; IEC 61547:2020
IEC 61326-2-3Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning
DIN EN 61326-1; VDE 0842-20-1:2013; DIN EN 61326-2-3:2013-07; VDE 0843-20-2-3:2013-07; DIN EN 61326-2-5:2013-08; VDE 0843-20-2-5:2013-08; DIN EN 61547; VDE 0875-15-2:2010-03; IEC 61547:2020
IEC 61326-2-5Name not checked yet
DIN EN 61326-1; VDE 0842-20-1:2013; DIN EN 61326-2-3:2013-07; VDE 0843-20-2-3:2013-07; DIN EN 61326-2-5:2013-08; VDE 0843-20-2-5:2013-08; DIN EN 61547; VDE 0875-15-2:2010-03; IEC 61547:2020
Scope as published by DAKKS
14 lines
ISO/IEC 17025
ActiveD-PL-20862-01-00
Location
Labs with overlapping accredited scope in Germany
- TQ-Systems GmbH TQ Product Compliance Center AugsburgAugsburg · ~109 kmDAKKSShares 3 accredited test methodsEN 61000-4-3EN 61000-6-3EN ISO 9001
- DEKRA Testing and CertificationStuttgart · ~243 kmDAKKSShares 3 accredited test methodsEN 61000-4-3EN 61000-6-3EN ISO 9001
- RS Schwarze Industrieelektronik GmbH EMV-LaboratoriumSchloss Holte-Stukenbrock · ~514 kmDAKKSShares 3 accredited test methodsEN 61000-4-3EN 61000-6-3EN ISO 9001
- ELMAC GmbH EMV-Labor J. BühneBondorf · ~256 kmDAKKSShares 2 accredited test methodsEN 61000-4-3EN ISO 9001
- PHOENIX TESTLABBlomberg · ~503 kmDAKKSShares 2 accredited test methodsEN 61000-6-3EN ISO 9001
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.