Micro Precision Calibration
9080 Activity Road, Suite C, 92126, San Diego, CA, United States
Visit website- Scope lines
- 25
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 25 scope lines.
A2LA certificate 935.10 · 25 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006 | Conductivity; pH | - |
| 2 | - | Height Gages; Gage blocks, surface plate; Micrometers; Flatness; Parallelism; Optical flat; Optical parallels; Micrometer Standards; Universal length measuring machine, gage blocks; Indicators – Dial & Digital Indicators, LVDTs; Rigid Rules & Tape Measures – Length; Ruler calibrator; Surface Plate – Local Flatness; Repeat-O-meter; Gage Blocks – Length; Gage block comparator, universal length measuring machine, gage blocks; Plain Cylindrical Ring Gages – Internal Diameter; Cylindrical Pin – Plug Gages; Thread WiresShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0935.10) Revised 03/24/2026 Page 2 of 24
Parameter/Equipment
Range
CMC2, 8 (±)
Comments
Height Gages
3
Up to 40 in
(62 + 1.7L) µin
Gage blocks, surface plate
Micrometers
3 –
Resolution:
10 µin
50 µin
100 µin
0.001 in
Flatness
Parallelism
Up to 1 in
Up to 4 in
(4 to 24) in
(24 to 40) in
50 µin
80 µin
(8.4 + 3.6L) µin
(29 + 2.3L) µin
(53 + 1.2L) µin
580 µin
8.0 µin
12 µin
Gage blocks
Optical flat
Optical parallels
Micrometer Standards
(1 to 20) in
(26 + 0.40L) µin
Universal length measuring
machine, gage blocks
Indicators – Dial & Digital
Indicators, LVDTs3
Up to 6 in
(3.0 + 3.0L) µin
Universal length measuring
machine, gage blocks
Rigid Rules & Tape
Measures3 – Length
Up to 96 in
0.0023 in
Ruler calibrator
Surface Plate
3 – Local
Flatness
(-1000 to 1000) µin
21 µin
Repeat-O-meter
Gage Blocks – Length
(0.05 to 4) in
(>4 to 20) in
(4.3 + 0.40L) µin
(0.50 + 1.3 L) µin
Gage block comparator,
universal length measuring
machine, gage blocks
Plain Cylindrical Ring
Gages – Internal Diameter
(0.05 to 12) in
(10 + 1.2L) µin
Universal length measuring
machine, gage blocks
Cylindrical Pin – Plug
Gages
Up to 12 in
(5.7 + 1.1L) µin
Universal length measuring
machine, gage blocks
Thread Wires,
(80 to 5) TPI
(0.007 to 0.1155) µin
(13 + 7.7L) µin
Universal length measuring
machine, gage blocks | See scope document |
| 3 | - | Thread Plug Gages; Thread Rings Gages; Universal Length Measuring Machine; Length Standards; Optical Comparators; Vision Systems & Measuring Microscopes; Fixture GagesShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0935.10) Revised 03/24/2026 Page 3 of 24
Parameter/Equipment
Range
CMC2, 8 (±)
Comments
Thread Plug Gages –
Major Diameter
Simple Pitch Diameter
(0.04 to 12) in
(0.04 to 12) in
(8.2 + 1.8L) µin
(30 + 2.8L) µin
Universal length
measuring machine, gage
blocks, master plug,
thread measuring wires
Thread Rings Gages –
Minor Diameter
Simple Pitch Diameter
(0.1 to 4) in
(0.1 to 4) in
(21 + 0.60L) µin
(22 + 7.0L) µin
Universal length
measuring machine, gage
blocks, master ring, T-
square probe
Universal Length
Measuring Machine3
Up to 4 in
(>4 to 20) in
(5.0 + 0.30L) µin
(1.0 + 1.2L) µin
Gage blocks
Length Standards
(Bars, Rods, Micrometers
Setting Standards, &
Fixtures Used as Length
Standards)
Up to 4 in
(>4 to 20) in
(8.0 + 0.80L) µin
(1.0 + 7.3L) µin
Gage blocks
ULMM
Optical Comparators
3 –
Vision Systems &
Measuring Microscopes
X & Y Axis – Error of
Indication
Angle
Up to 1 in
(>1 to 8) in
Up to 90°
(56 + 27L) µin
(81 + 2.3L) µin
4.3 arcsecond
Gage blocks
Glass scale
Fixture Gages – Non-
Contact Measurements –
Length
Angle
Up to 7 in
Up to 90°
(97 + 3.3L) µin
4.3 arcsecond
Optical comparator | See scope document |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0935.10) Revised 03/24/2026 Page 4 of 24
III. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Voltage
3 – Generate
(0 to 100) mV
>100 mV to 1 V
(>1 to 10) V
(>10 to 100) V
(>100 to 1100) V
2.8 µV/V + 360 nV
3.0 µV/V + 620 nV
1.0 µV/V + 3.2 µV
4.2 µV/V + 18 µV
5.2 µV/V + 22 µV
Multiproduct calibrator
DC Voltage3 – Measure
(0 to 100) mV
>100 mV to 1 V
(>1 to 10) V
(>10 to 100) V
(>100 to 1000) V
(>1000 to 10 000) V
(>10 000 to 100 000) V
600 nV/V + 260 nV
2.8 µV/V + 44 nV
3.5 µV/V – 560 nV
3.0 µV/V + 10 µV
8.7 µV/V – 500 µV
10 µV/V + 4.0 µV
25 µV/V + 1.0 µV
Multimeter
Multimeter / high
voltage probe
DC Current
3 – Generate
(0 to 100) µA
>100 µA to 1 mA
(>1 to 10) mA
(>10 to 100) mA
>100 mA to 1 A
(>1 to 11) A
1.0 µA/A + 3.0 nA
33 µA/A + 0.11 nA
57 µA/A – 24 nA
210 µA/A – 1.5 µA
100 µA/A + 9.0 µA
950 µA/A – 870 nA
Multi-function
calibrator
DC Current
3 – Measure
Up to 100 µA
(>0.1 to 1) mA
(>1 to 10) mA
(>10 to 100) mA
(>0.1 to 1) A
(>1 to 11) A
(>11 to 600) A
44 µA/A
36 µA/A + 0.60 nA
36 µA/A + 1.0 nA
120 µA/A – 820 nA
120 µA/A – 1.0 µA
310 nA/A + 5.0 µA
75 µA/A – 650 µA
Multimeter
Multimeter with shunt
DC Current3 –
Toroidal Clamp Meter
Other Type Clamp Meter
(9.5 to 550) A
(9.5 to 550) A
3.0 mA/A + 4.0 mA
6.0 mA/A + 18 mA
Multi-product
calibrator W/50 turn
coil
DC Power3 – Generate
(1 to 10) W
(>10 to 100) W
(>100 to 1000) W
(>1000 to 5000) W
(>5000 to 10 000) W
17 µW/W + 930 µW
95 µW/W
54 µW/W + 4.0 mW
5.0 µW/W + 53 mW
100 µW/W – 430 mW
Multi-product
calibrator | ||
| 5 | - | AC VoltageShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0935.10) Revised 03/24/2026 Page 5 of 24
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage
3 – Generate
Up to 0.022 V
(>0.022 to 0.220) V
(>0.220 to 2.2) V
(>2.2 to 22) V
(>22 to 220) V
(>220 to 1100) V
Up to 20 Hz
(>20 to 40) Hz
>40 Hz to 20 kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
>500 kHz to 1 MHz
Up to 20 Hz
(>20 to 40) Hz
>40 Hz to 20 kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
>500 kHz to 1 MHz
Up to 20 Hz
(>20 to 40) Hz
>40 Hz to 20 kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
>500 kHz to 1 MHz
Up to 20 Hz
(>20 to 40) Hz
>40 Hz to 20 kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
>500 kHz to 1 MHz
Up to 20 Hz
(>20 to 40) Hz
>40 Hz to 20 kHz
(>20 to 50) kHz
(>50 to 100) kHz
≤50 Hz
(>50 to 300) Hz
>300 Hz to 1 kHz
320 µV/V + 1.3 µV
200 µV/V + 1.0 µV
44 µV/V + 1.3 µV
360 µV/V + 1.0 µV
630 µV/V + 4.3 µV
1.3 mV/V + 11 µV
1.7 mV/V + 14 µV
2 mV/V + 12 µV
250 µV/V + 1.4 µV
110 µV/V + 1.1 µV
48 µV/V + 1.3 µV
130 µV/V + 1.2 µV
170 µ
V/V + 5.3 µV
540 µV/V + 13 µV
820 µV/V + 15 µV
1.2 mV/V + 13 µV
240 µV/V + 1.4 µV
74 µV/V + 1.2 µV
34 µV/V + 1.3 µV
59 µV/V + 1.4 µV
67 µV/V + 5.5 µV
220 µV/V + 14 µV
690 µV/V + 16 µV
840 µV/V + 13 µV
250 µV/V + 1.4 µV
75 µV/V + 1.2 µV
44 µV/V + 1.3 µV
55 µV/V + 1.4 µV
70 µV/V + 5.5 µV
180 µV/V + 14 µV
600 µV/V + 16 µV
700 µV/V + 14 µV
250 µ
V/V + 1.4 µV
90 µV/V + 1.1 µV
44 µV/V + 1.3 µV
28 µV/V + 1.4 µV
120 µV/V + 5.4 µV
55 µV/V + 2.0 µV
58 µV/V + 1.0 µV
61 µV/V + 1.1 µV
Multi-function
calibrator | - |
| 6 | - | AC VoltageShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0935.10) Revised 03/24/2026 Page 6 of 24
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage
3 – Measure
Up to 0.01 V
(>0.01 to 0.1) V
(>0.1 to 1) V
(>1 to 10) V
(>10 to 100) V
(>100 to 1000) V
Up to 40 Hz
>40 Hz to 1 kHz
(>1 to 20) kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
>300 kHz to 1 MHz
(>1 to 2) MHz
Up to 40 Hz
>40 Hz to 1 kHz
(>1 to 20) kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
>300 kHz to 1 MHz
(>1 to 2) MHz
Up to 40 Hz
>40 Hz to 1 kHz
(>1 to 20) kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
>300 kHz to 1 MHz
(>1 to 2) MHz
Up to 40 Hz
>40 Hz to 1 kHz
(>1 to 20) kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
>300 kHz to 1 MHz
(>1 to 2) MHz
Up to 40 Hz
>40 Hz to 1 kHz
(>1 to 20) kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
>300 kHz to 1 MHz
Up to 40 Hz
330 µV/V + 4.0 µV
170 µV/V + 2.0 µV
390 µV/V + 2.0 µV
1.2 mV/V + 2.0 µV
3.2 mV/V + 3.0 µV
13 mV/V + 25 µV
13 mV/V + 16 µV
4.4 mV/V + 170 µV
94 µV/V + 5.0 µV
97 µV/V + 2.0 µV
180 µV/V + 2.0 µV
360 µV/V + 2.0 µV
980 µV/V + 2.0 µV
3.4 mV/V + 23 µV
12
mV/V + 11 µV
16 mV/V + 66 µV
83 µV/V + 47 µV
87 µV/V + 23 µV
170 µV/V + 23µV
350 µV/V + 23 µV
930 µV/V + 27 µV
3.5 mV/V + 120 µV
12 mV/V + 120 µV
17 mV/V + 210 µV
84 µV/V + 460 µV
62 µV/V + 480 µV
170 µV/V + 220 µV
350 µV/V + 230 µV
920 µV/V + 280 µV
3.5 mV/V + 1.1 mV
12 mV/V + 1.0 mV
18 mV/V + 170 µV
230 µV/V + 4.5 mV
240 µV/V + 2.2 mV
250 µV/V + 2.1 mV
410 µV/V + 2.3 mV
1.4 mV/V + 2.2 mV
4.6 mV/V + 12 mV
17 mV/V + 22 mV
480 µV/V + 45 mV
Multimeter,
synchronous sub-
sampled mode | - |
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0935.10) Revised 03/24/2026 Page 7 of 24
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage
3 – Measure
(cont)
(>100 to 1000) V
(1000 to 30 000) kV
(1000 to 30 000) kV
>40 Hz to 1 kHz
(>1 to 10) kHz
(>10 to 100) kHz
60 Hz
1 kHz
470 µV/V + 22 mV
700 µV/V + 23 mV
1.4 mV/V + 20 mV
6.0 µV/V + 3.0 µV
4.0 µV/V - 38 µV
Multimeter / high
voltage divider,
synchronous sub-
sampled mode
AC Current
3 – Generate
Up to 2.2 mA
(>2.2 to 22) mA
(>22 to 220) mA
Up to 2.2 mA
(>2.2 to 22) mA
(>22 to 220) mA
>220 mA to 2.2 A
Up to 2.2 mA
(>2.2 to 22) mA
(>22 to 220) mA
>220 mA to 2.2 A
Up to 2.2 mA
(>2.2 to 22) mA
(>22 to 220) mA
>220 mA to 2.2 A
Up to 2.2 mA
(>2.2 to 22) mA
(>22 to 220) mA
>220 mA to 2.2 A
(2.2 to 11) A
(10 to 20) Hz
(>20 to 40) Hz
>40 Hz to 1 kHz
(>1 to 5) kHz
(>5 to 10) kHz
Up to 65 Hz
(>65 to 500) Hz
>500 Hz to 1 kHz
160 µA/A + 48 nA
200 µA/A + 11 nA
76 mA/A + 1.2 mA
39 µA/A + 26 nA
120 µA/A - 50 nA
86 µA/A + 230 nA
71 µA/A + 1.8 µA
42 µA/A + 23 nA
110 µA/A - 50 nA
86 µA/A + 230 nA
71 µA/A + 1.8 µA
12 µA/A + 66 nA
110 µA/A – 36 nA
67 µA/A + 420 nA
61 µA/A + 1.1 µA
160 µA/A + 84 nA
140 µA/A + 100 nA
55 µA/A + 940 nA
420 µA/A + 35 µA
300 µA/A + 67 µA
420 µA/A + 11 µ
A
370 mA/A + 400 µA
Multi-function
calibrator | ||
| 8 | - | AC CurrentShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0935.10) Revised 03/24/2026 Page 8 of 24
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current
3 – Measure
Up to 100 µA
>100 µA to 1 mA
(>1 to 100) mA
>100 mA to 1 A
Up to 100 µA
>100 µA to 1 mA
(>1 to 100) mA
>100 to 1 A
Up to 100 µA
>100 µA to 1 mA
(>1 to 10) mA
(>10 to 100) mA
>100 to 1 A
Up to 100 µA
>100 µA to 1 mA
(>1 to 10) mA
(>10 to 100) mA
>100 to 1 A
>100 µA to 1 mA
(>1 to 10) mA
(>10 to 100) mA
>100 mA to 1 A
>100 µA to 1 mA
(>1 to 10) mA
(>10 to 100) mA
>100 mA to 1 A
>100 µA to 1 mA
(>1 to 10) mA
(>10 to 100) mA
(>1 to 10) A
(>10 to 600) A
Up to 20 Hz
(>20 to 45) Hz
(>45 to 100) Hz
>100 Hz to 5 kHz
(>5 to 20) kHz
(>20 to 50) kHz
(>50 to 100) kHz
Up to 1 kHz
(>1 to 50) kHz
Up to 50 kHz
4.6 mA/A + 34 nA
4.8 mA/A + 22 nA
4.8 mA/A
4.9 mA/A – 11
1.8 mA/A + 34 nA
2.0 mA/A + 11 nA
2.0 mA/A
2.0 mA/A – 11 µA
640 µA/A + 36 nA
920 µA/A + 8.0 nA
930 µA/A
930 µA/A + 1.0 nA
1.2 mA/A – 30 µA
640 µA/A + 36 nA
530 µ
A/A + 47nA
580 µA/A
580 µA/A + 1.0 nA
1.5 mA/A - 91 µA
700 µA/A + 230 nA
930 µA/A
930 µA/A + 3.0 nA
4 mA/A – 310 µA
4.6 mA/A + 460 nA
5.1 mA/A – 1.0 nA
5.1 mA/A + 15 nA
13 mA/A – 760 µA
6.3 mA/A + 1.8 µA
8.1 mA/A – 2.0 nA
8.1 mA/A + 24 nA
930 µA/A + 11 µA
950 µA/A
4.9 mA/A + 2.8 mA
Multimeter
Multimeter with shunt | - |
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0935.10) Revised 03/24/2026 Page 9 of 24
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current
3 – Measure
(cont)
Toroidal Clamp Meter:
(9.5 to 550) A
Other Type Clamp
Meter:
(9.5 to 550) A
Up to 65 Hz
(>65 to 440) Hz
Up to 65 Hz
(>65 to 440) Hz
3.0 mA/A + 3.0 mA
10 mA/A – 6.0 mA
8.0 mA/A + 18 mA
14 mA/A + 7.0 mA
Multi-product
calibrator W/50 turn
coil
AC Power
3 – Generate –
PF = (0 to 1)
(1 to 10 000) W
45 Hz to 1 kHz
57 µW/W + 2.0 mW
Multi-product
calibrator
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Resistance
3 – Measure
(0 to 9.99) Ω
(10 to 99.99) Ω
100 Ω to 0.999 kΩ
(1 to 9.99) kΩ
(10 to 99.99) kΩ
100 kΩ to 0.99 MΩ
(1 to 9.99) MΩ
(10 to 99.99) MΩ
100 MΩ to 1 GΩ
57 µΩ/Ω + 28 µΩ
38 µΩ/Ω + 220 µΩ
24 µΩ/Ω + 1.6 mΩ
29 µΩ/Ω - 3.0 mΩ
18 µΩ/Ω + 110 mΩ
12 µΩ/Ω + 780 mΩ
170 µΩ/Ω – 150 Ω
220 µΩ/Ω – 670 Ω
6.4 mΩ/Ω – 620 kΩ
Multimeter
Resistance
3 – Generate
(0 to 10.99) Ω
(11 to 32.99) Ω
(33 to 109.99) Ω
(110 to 329.99) Ω
330 Ω to 1.099 kΩ
(1.1 to 3.299) kΩ
(3.3 to 10.99) kΩ
(11 to 32.99) kΩ
(33 to 109.99) kΩ
(110 to 329.99) kΩ
330 kΩ to 1.099 MΩ
(1.1 to 3.299) MΩ
(3.3 to 10.99) MΩ
26 µΩ/Ω + 150 µΩ
31 µΩ/Ω + 2.6 mΩ
4.0 µΩ/Ω + 2.7 mΩ
1.0 µΩ/Ω + 1.7 mΩ
45 µΩ/Ω – 7.5 mΩ
62 µΩ/Ω – 25 mΩ
90 µΩ/Ω – 110 mΩ
1.6 µΩ/Ω + 420 mΩ
48 µΩ/Ω - 1.0 Ω
19 µΩ/Ω + 2.2 Ω
150 µΩ/Ω – 38 Ω
63 µΩ/Ω + 62 Ω
890 µΩ/Ω - 2.4 kΩ
Multi-product
calibrator | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0935.10) Revised 03/24/2026 Page 10 of 24
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Resistance
3 – Generate
(cont)
Fixed Points
(11 to 32.99) MΩ
(33 to 109.99) MΩ
(110 to 330) MΩ
0 Ω
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
1 GΩ
10 GΩ
100 GΩ
1 TΩ
10 TΩ
610 µΩ/Ω + 620 Ω
570 µΩ/Ω + 1.9 kΩ
3.0 mΩ/Ω – 0.29 MΩ
20 µΩ
110 µΩ
210 µΩ
140 µΩ
580 µΩ
1.5 mΩ
2.2 mΩ
10 mΩ
19 mΩ
100 mΩ
190 mΩ
1.3 Ω
3.0 Ω
7.0 Ω
91 Ω
320 Ω
6.8 kΩ
33 kΩ
12 MΩ
580 MΩ
5.8 GΩ
67 GΩ
1.3 TΩ
Multi-product
calibrator
Resistance box
Inductance
3 – Measuring
Equipment
(100 to 1000) µH
(>1 to 10) mH
(>10 to 100) mH
(>100 to 1000) mH
1.0 % IV + 1.6 µH
1.8 % IV mH
1.8 % IV – 0.090 mH
0.92 % IV + 0.060 mH
Decade inductor
IV= indicated value
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
Capacitance
3 – Measuring
Equipment
Up to 3.29 nF
(3.29 to 32.9) nF
(>32.9 to 329.9) nF
50 Hz to 1 kHz
0.27 % IV + 0.0090 nF
0.30 % IV – 0.014 nF
0.14 % IV + 0.11 nF
Multi-product
calibrator
IV= indicated value | ||
| 11 | - | capacitance; thermocouple indicatorsShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0935.10) Revised 03/24/2026 Page 11 of 24
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
Capacitance3 – Measuring
Equipment (cont)
(>329.9 to 1.09) µF
(>1.09 to 3.29) µF
(>3.29 to 32.9) µF
(>32.9 to 329.9) µF
(>0.33 to 1.1) mF
(100 to 1000) pF
(>1000 to 10 000) pF
(>0.01 to 0.1) µF
(>0.1 to 1) µF
50 Hz to 1 kHz
0.15 % IV – 0.30 pF
0.37 % IV – 2.4 nF
0.33 % IV – 10 nF
0.54 % IV – 0.32 µF
0.27 % IV + 0.50 µF
0.020 % IV + 0.11 pF
0.061 % IV - 0.31 pF
0.054 % IV + 4.0 pF
0.085 % IV - 30 pF
Multi-product
calibrator
Decade capacitor
IV= indicated value
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Electrical Calibration of
Thermocouple Indicators
3
Type B
Type C
Type E
Type J
Type K
Type N
Type R
Type S
Type T
(600 to 800) °C
(800 to 1000) °C
(1000 to 1820) °C
(0 to 1800) °C
(1800 to 2310) °C
(-250 to 1000) °C
(-210 to 1200) °C
(-200 to 1372) °C
(-200 to -1300) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1767) °C
(0 to 250) °C
(250 to 1760) °C
(-250 to -150) °C
(-150 to 400) °C
0.35 °C
0.29 °C
0.23 °C
0.20 °C
0.24 °C
0.070 °C
0.080 °C
0.10 °C
0.10 °C
0.31 °C
0.25 °C
0.21 °C
0.33 °C
0.24 °C
0.12 °C
0.078 °C
Multi-product
calibrator | - |
| 12 | - | Thermocouple; RTD Indicating SystemsShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0935.10) Revised 03/24/2026 Page 12 of 24
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Electrical Calibration of
Thermocouple –
Measure
3
Type B
Type C
Type E
Type J
Type K
Type N
Type R
Type S
Type T
(600 to 1000) °C
(1000 to 1820) °C
(0 to 150) °C
(150 to 1000) °C
(1000 to 1800) °C
(1800 to 2310) °C
(-250 to 350) °C
(350 to 1000) °C
(-210 to -100) °C
(-100 to 1200) °C
(-200 to 1372) °C
(-200 to -1300) °C
(0 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 1760) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.35 °C
0.26 °C
0.19 °C
0.15 °C
0.18 °C
0.24 °C
0.070 °C
0.080 °C
0.090 °C
0.080 °C
0.10 °C
0.094 °C
0.31 °C
0.26 °C
0.21 °C
0.24 °C
0.095 °C
0.082 °C
0.090 °C
0.082 °C
Multimeter
Electrical Calibration of
RTD Indicating Systems
3
–
Pt 385, 100 Ω
Pt 3926, 100 Ω
(-200 to 0)
°C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(-200 to 0) °C
(0 to 100) °C
(100 to 300) °C
0.058
°C
0.081 °C
0.10 °C
0.12 °C
0.14 °C
0.27
°C
0.058 °C
0.081 °C
0.10 °C
Multi-product
calibrator | See scope document |
| 13 | - | RTD Indicating Systems; OscilloscopeShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0935.10) Revised 03/24/2026 Page 13 of 24
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
RTD Indicating Systems
3 –
(cont)
Pt 3926, 100 Ω
Pt 3916, 100 Ω
Pt 385, 200 Ω
Pt 385, 500 Ω
Pt 385, 1 kΩ
PtNi 385, 120 Ω
Cu 427, 10 Ω
(300 to 400) °C
(400 to 630)
°C
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to 100)
°C
(100 to 260) °C
(260 to 600) °C
(600 to 630) °C
(-200 to -80)
°C
(-80 to 100) °C
(100 to 260) °C
(260 to 400) °C
(400 to 600) °C
(600 to 630)
°C
(-200 to 0) °C
(0 to 100) °C
(100 to 260)
°C
(260 to 300) °C
(300 to 600) °C
(600 to 630)
°C
(-80 to 100) °C
(1000 to 260) °C
(-100 to 260)
°C
0.12
°C
0.14 °C
0.29
°C
0.046 °C
0.058 °C
0.070 °C
0.081 °C
0.093 °C
0.10 °C
0.12 °C
0.27 °C
0.047
°C
0.058 °C
0.16 °C
0.18 °C
0.047
°C
0.058 °C
0.070 °C
0.093 °C
0.010 °C
0.13
°C
0.035 °C
0.047 °C
0.058 °C
0.070 °C
0.081
°C
0.27 °C
0.093 °C
0.16
°C
0.36
°C
Multi-product
calibrator
Oscilloscope3 –
DC Vertical Deflection
Accuracy:
50 Ω Load
(1 to 10) mV
(>10 to 100) mV
(>100 to 1000) mV
(>1 to 5) V
4.0 μV
45 μV
500 μV
3.0 mV
Scope calibrator
w/active probe | - |
| 14 | - | OscilloscopeShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0935.10) Revised 03/24/2026 Page 14 of 24
Parameter/Equipment
Range
CMC2 (±)
Comments
Oscilloscope3 – (cont)
DC Vertical Deflection
Accuracy: 1 MΩ Load
Vertical Deflection Accuracy:
50 Ω Load
Square Wave Signal
<10kHz
Vertical Deflection Accuracy:
1 MΩ Load
Square Wave Signal
<10kHz
Horizontal Cursor
Accuracy (Time Base)
(1 to 10) mV
(>10 to 100) mV
(>100 to 1000) mV
(>1 to 10) V
(>10 to 100) V
(>100 to 220) V
(1 to 10) mV
(>10 to 100) mV
(>100 to 1000) mV
(>1 to 5) V
(1 to 10) mV
(>10 to 100) mV
(>100 to 1000) mV
(>1 to 10) V
(>10 to 100) V
(>100 to 220) V
5 s
2 s
1 s
500 ms
200 ms
100 ms
50 ms
20 ms
10 ms
5 ms
2 ms
1 ms
500 μs
200 μs
100 μs
50 μs
20 μs
10 μs
5 μs
2 μs
1 μs
500 ns
200 ns
100 ns
4.0 μV
54 μV
390 μV
5.0 mV
33 mV
350 mV
4.0 μV
38 μV
450 μV
3.0 mV
5.0 μV
40 μV
400 μV
4.0 mV
39 mV
490 mV
4.0 ms
2.0 ms
2.0 ms
0.39 ms
0.35 ms
0.28 ms
46 µs
39 µs
35 µs
4.0 µs
4.0 µs
2.0 µs
0.41 µs
0.34 µs
0.22 µs
62 ns
49 ns
47 ns
4.0 ns
3.0 ns
2.0 ns
0.62 ns
0.37 ns
0.33 ns
Scope calibrator
w/active probe | See scope document |
| 15 | - | Oscilloscope; RF Tuned Power; RF Absolute PowerShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0935.10) Revised 03/24/2026 Page 15 of 24
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
Oscilloscope3 – (cont)
Horizontal Cursor
Accuracy (Time Base)
Bandwidth 50 Ω
Bandwidth 50 Ω,
Relative to 50 kHz
Rise / Fall Time
3.4 ns
14 ns
50 ns
20 ns
10 ns
5 ns
2 ns
50 kHz
50 kHz to 100 MHz
(>100 to 300) MHz
(>300 to 600) MHz
600 MHz to 26.5 GHz
(>26.5 to 50) GHz
50 kHz to 100 MHz
(>100 to 300) MHz
(>300 to 600) MHz
600 MHz to 26.5 GHz
(>26.5 to 50) GHz
(10 to 90) %
(10 to 90) %
54 ps
33 ps
27 ps
4.0 ps
3.0 ps
0.44 %
0.71 %
0.76 %
0.81 %
1.1 %
1.9 %
0.38 %
0.78 %
0.83 %
1.1 %
1.9 %
0.39 ns
0.43 ns
Scope calibrator
w/active probe
Multi-product
calibrator
power splitter, power
sensors
power meter
IV. Electrical – RF/Microwave
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
RF Tuned Power
3 – Measure
(20 to -30) dB
(-30 to -130) dB
150 kHz to 26.5 GHz
0.15 dB
0.19 dB
Measurement
receiver
RF Absolute Power
3 –
Measure
(-20 to 20) dB
(-20 to 20) dB
(-20 to 20) dB
(-70 to -20) dB
(-70 to -20) dB
(-70 to -20) dB
9 kHz to 18 GHz
(>18 to 40) GHz
(>40 to 50) GHz
(0.01 to 18) GHz
(>18 to 40) GHz
(>40 to 50) GHz
0.060 dB
0.090 dB
0.16 dB
0.075 dB
0.14 dB
0.23 dB
Coaxial thermistor
& thermocouple
power sensors | - |
| 16 | - | Power Meter; Power SensorShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0935.10) Revised 03/24/2026 Page 16 of 24
Parameter/Range
Frequency
CMC2, 5, 7 (±)
Comments
Power Meter
3 –
Measurement Accuracy:
(-30 to -130) dB
50 MHz Power Reference
100 mW
30 mW
10 mW
3.0 mW
1 mW
300 µW
100 µW
30 µW
10 µW
3 µW
0 mW
1 mW
0.32 mW
93 µW
32 µW
9.3 µW
3.2 µW
0.93 µW
0.32 µW
93 nW
32 nW
9.3 nW
0.72 nW
7.9 µW
Range calibrator,
multimeter,
coaxial thermistor &
thermocouple power
sensors
Power meter &
power sensor
Power Sensor Calibration
Factor
3 –
(-20 to 20) dB
(-70 to -20) dB
50 MHz
9 kHz to 0.001 GHz
(>0.001 to 0.01) GHz
(>0.01 to 2) GHz
(>2 to 4.2) GHz
(>4.2 to 12.4) GHz
(>12.4 to 18) GHz
(>18 to 22) GHz
(>22 to 26.5) GHz
(>26.5 to 40) GHz
(>40 to 50) GHz
(0.01 to 0.03) GHz
(>0.03 to 4) GHz
(>4 to 18) GHz
(>18 to 34) GHz
(>34 to 40) GHz
(>40 to 50) GHz
1.1 %
1.5 %
1.2 %
1.1 %
1.5 %
1.5 %
1.7 %
2.2 %
2.3 %
2.8 %
4.6 %
1.8 %
1.8 %
2.1 %
3.4 %
4.2 %
6.9 %
Coaxial thermistor
& thermocouple
power sensors
Frequency Modulation
Rejection
3 – Equipment
Rate: 400 HZ to 1 kHz
Dev.: ≤5 kHz peak
Dev.: ≤50 kHz peak
Residuals AM3
250 kHz to 10 MHz
10 MHz to 26.5 GHz
150 kHz to 26.5GHz
0.12 % AM
0.12 % AM
0.0073 % (rms)
Measuring receiver | - |
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0935.10) Revised 03/24/2026 Page 17 of 24
Parameter/Range
Frequency
CMC2 (±)
Comments
Frequency Modulation
Distortion
3 –
Bandwidth: 20 Hz to 250
kHz
150 kHz to 26.5 GHz
0.12 % IV
Measuring receiver
IV = indicated value
Frequency Modulation3 –
Magnitude Deviation
Rate: 20 Hz to 10 kHz
Dev: ≤ 40 kHz
Rate: 50 Hz to 200 kHz
Dev: ≤ 400 kHz
Rate: 50 Hz to 200 kHz
Dev: ≤ 400 kHz
Rate: 50 Hz to 200 kHz
Dev: ≤ 400 kHz
250 kHz to 10 MHz
10 MHz to 6.6 GHz
(6.6 to 13.2) GHz
(13.2 to 26.5) GHz
0.10 Hz
0.20 Hz
0.40 Hz
0.50 Hz
Measuring receiver
Amplitude Modulation
3 –
Rejection
Rate: 400 HZ to 1 kHz
Depth.: ≤50 %
150 kHz to 6.6 GHz
(6.6 to 13.2) GHz
(13.2 to 26.5) GHz
17 Hz
27 Hz
50 Hz
Measuring receiver
Amplitude Modulation3 –
Depth
Rate: 50 Hz to 10 kHz
Depth: (5 to 99) %
Rate: 50 Hz to 100 kHz
Depth: (20 to 99) %
Rate: 50 Hz to 100 kHz
Depth: (5 to 20) %
Rate: 50 Hz to 100 kHz
Depth: (20 to 99) %
Rate: 50 Hz to 100 kHz
Depth: (5 to 20) %
150 kHz to 10 MHz
10 MHz to 3 GHz
10 MHz to 3 GHz
(3 to 26.5) GHz
(3 to 26.5) GHz
0.20 % IV
0.30 % IV
0.30 % IV
0.90 % IV
0.50 % IV
Measuring receiver
IV = indicated value | ||
| 18 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0935.10) Revised 03/24/2026 Page 18 of 24
Parameter/Range
Frequency
CMC2 (±)
Comments
Amplitude Modulation
3 –
Flatness
Rate: (9 Hz to 10 kHz)
Depth: (5 to 99) %
10 MHz to 26.5 GHz
0.15 % IV
Measuring receiver
IV = indicated
value
Residuals FM3 –
Bandwidth: 50 Hz to 3 kHz
150 kHz to 10 MHz
(3 to 6.6) GHz
(6.6 to 13.2) GHz
(13.2 to 26.5) GHz
1.3 Hz
1.9 Hz
2.7 Hz
3.8 Hz
Measuring receiver
Amplitude Modulation3 –
Distortion
Rate: 20 Hz to 250 kHz BW
(0.01 to 100) %
150 kHz to 26.5 GHz
0.14 % IV
Measuring receiver
IV = indicated
value
Phase Modulation3 – Accuracy
–
Rate: 20 Hz to 200 kHz
Deviation: >0.7 Rad
Deviation: >0.3 Rad
Rate: 20 Hz to 200 kHz
Deviation: >2 Rad
Deviation: >0.6 Rad
Rate: 20 Hz to 200 kHz
Deviation: >4 Rad
Deviation: >1.2 Rad
100 kHz to 6.6 GHz
100 kHz to 6.6 GHz
(6.6 to 13.2) GHz
(6.6 to 13.2) GHz
(13.2 to 26.5) GHz
(13.2 to 26.5) GHz
0.10 % IV
0.20 % IV
0.10 % IV
0.20 % IV
0.10 % IV
0.20 % IV
Measuring receiver
IV = indicated
value
Phase Residuals
3
Rate: 50 Hz to 3 kHz
100 kHz to 26.5 GHz
0.010 rad
Measuring receiver | ||
| 19 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0935.10) Revised 03/24/2026 Page 19 of 24
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
Phase Distortion
3 –
Bandwidth: 20 Hz to 250 kHz
150 kHz to 26.5 GHz
0.14 % IV
Measuring receiver
IV = indicated value
Harmonics3 – Measure
30 Hz to 50 GHz
1.3 dB
Spectrum analyzer
Reflection Magnitude & Phase
S
11/22 – Measure3
5 Hz to 500 MHz
0.064 lin 0.36°
Vector network
analyzer, calibration
kit & network analyze
r
Transmission Magnitude &
Phase S
21/12 – Measure3
5 Hz to 500 MHz
0.014 dB 0.36°
Vector network
analyzer, calibration
kit & network analyze
r
Reflection Magnitude & Phase
S
11/22 – Measure3
30 Hz to 1.3 GHz
(>1.3 to 3) GHz
(>3 to 6) GHz
(>6 to 8) GHz
(>8 to 18) GHz
(>18 to 26.5) GHz
0.002 lin 0.6°
0.002 lin 1.3°
0.004 lin 1.7°
0.005 lin 1.5°
0.010 lin 1.5°
0.013 lin 1.5°
Network analyzer, cal
kit
Transmission Magnitude &
Phase S
21/12 – Measure3
30 Hz to 1.3 GHz
(>1.3 to 3) GHz
(>3 to 6) GHz
(>6 to 8) GHz
(>8 to 18) GHz
(>18 to 26.5) GHz
0.060 dB 0.4°
0.080 dB 0.8°
0.15 dB 0.8°
0.12 dB 1.8°
0.23 dB 1.8°
0.29 dB 1.8°
Network analyzer, cal
kit
Impedance S
11/22 – Measure3
5 Hz to 500 MHz
30 Hz to 3 GHz
(>3 to 6) GHz
(>6 to 8) GHz
(>8 to 18) GHz
(>18 to 26.5) GHz
6.4 % IV
0.20 % IV
0.40 % IV
0.50 % IV
1.0 % IV
1.3 % IV
Network analyzer, cal
kit
IV= indicated value
Input Noise Level – Measure
3
30 Hz to 26.5 GHz
0.70 dB
Cal kit | ||
| 20 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0935.10) Revised 03/24/2026 Page 20 of 24
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
Trace Noise Magnitude &
Phase
3 – Measure
30 Hz to 3 GHz
(>3 to 20) GHz
(>20 to 26.5) GHz
0.070 dB 1.0°
0.20 dB 2.3°
0.30 dB 3.2°
Cal kit
Insertion Delay
3 –
Group Delay Flatness
F0= +/- 21 MHz
220 MHz to 6 GHz
220 MHz to 6 GHz
0.40 ns
0.40 ns
Network
analyzer,
calibration unit
V. Mechanical
Parameter/Equipment
Range
CMC
2, 7 (±)
Comments
Pressure
3 – Measure &
Measuring Equipment
(-25 to 25) in H2O
(-15 to 0) psi
(0 to 15) psi
(>15 to 300) psi
(>300 to 500) psi
(>500 to 15 000) psi
0.0030 in H
2O
0.0019 psi
0.0018 psi
0.037 psi
0.012 % IV + 0.000 43 psi
0.014 % IV + 1.2 psi
Pressure
calibrator
IV= indicated
value
Dead weight
tester
Torque Tools
3 – Measure
(0.1 to 199.9) ozfꞏin
(0.15 to 9) lbfꞏin
(10 to 100) lbfꞏin
(0.1 to 200) lbf∙ft
(>200 to 1000) lbf∙ft
1.2 % IV + 0.05 ozfꞏin
0.030 % IV + 0.05 lbfꞏin
0.50 % IV + 0.1 lbfꞏin
0.60 % IV + 0.04 lbf∙ft
1.3 % IV – 0.9 lbf∙ft
Torque
calibrator
IV= indicated
value
Torque Analyzers &
Transducers
3 – Measure
Up to 100 lbfꞏin
0.020 % IV + 0.060 lbfꞏin
Torque
wheel/arm,
weights
Mass
(1 to 100) mg
200 mg
500 mg
3.2 µg
6.0 µg
6.1 µg
Ultra Class,
class 0 & 1
weights with
balance | ||
| 21 | - | weights; scales; balances; pipettes; syringes; burettes; dispensers; liquid handlers; titrators; dilutors; accelerometersShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0935.10) Revised 03/24/2026 Page 21 of 24
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Mass (cont)
1 g
2 g
5 g
10 g
20 g
50 g
100 g
200 g
500 g
1 kg
2 kg
3 kg
5 kg
10 kg
15 kg
20 kg
25 kg
8.4 µg
8.6 µg
10 µg
12 µg
16 µg
30 µg
52 µg
100 µg
0.60 mg
790 µg
2.1 mg
1.6 mg
2.6 mg
5.3 mg
5.9 mg
6.4 mg
6.7 mg
Ultra Class, class 0
& 1 weights with
balance
Class 1, 2, & 3
weights with
balance
Scales & Balances3
Up to 250 g
>250 g to 25 kg
(>25 to 200) kg
1.5 µg/g + 7.0 µg
0.30 µg/g + 57 µg
0.23 µg/g + 2.3 mg
Ultra Class,
Class 1 & 3
weights,
Class F weights
POVA (Piston/Plunger
Operated Volumetric
Apparatus) Pipettes,
Syringes,
Piston/Displacement
Burettes, Dispensers,
Liquid Handlers, Titrators,
& Dilutors
Up to 50 µL
(>0.050 to 200) mL
0.12 % IV + 23 nL
0.17 % IV
Analytical balance
IV = indicated
value
Accelerometers –
Frequency Response
10 Hz to 2 kHz
(>2 to 10) kHz
(1 to 5) g
1.6 % IV
2.2 % IV
Vibration
calibration system,
standard
accelerometers
IV = indicated
value | - |
| 22 | - | Force; Humidity; TemperatureShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0935.10) Revised 03/24/2026 Page 22 of 24
Parameter/Equipment
Range
CMC2, 5, 7 (±)
Comments
Force
3 – Measure &
Measuring Equipment
Tension
Compression
Up to 500 lbf
Up to 25 000 lbf
(>25 000 to 50 000) lbf
(>50 000 to 100 000) lbf
0.0060 % + 0.0060 lbf
0.0010 % + 0.50 lbf
0.0010 % + 0.70 lbf
0.0010 % + 0.70 lbf
Load cell
& press
VI. Thermodynamics
Parameter/Equipment
Range
CMC
2, 7 (±)
Comments
Humidity
8 –
Measuring Equipment
(11 to 75) % RH
(>75 to 99) % RH
0.010 % RH / % RH + 0.50 % RH
0.080 % RH / % RH + 0.50 % RH
Humidity
salts
Humidity
3, 8 –
Measure
(0 to 11) % RH
(>11 to 33) % RH
(>33 to 100) % RH
0.022 % RH / % RH + 0.51 % RH
0.0010 % RH / % RH + 0.75 % RH
0.0070 % RH / % RH + 0.55 % RH
Humidity
meter
Temperature3 –
Measuring Equipment
(Industrial/Process)
(-80 to 420) °C
(>420 to 450) °C
0.030 °C
0.070 °C
Bath,
drywell
calibrator
temperatur
e
meter,
SPRT
ITS-90
SPRT, PRT, RTD
Probes
Resistance Values
Temperature
Coefficients
(-80 to <0.01) °C
a 4
b 4
(≥0.01 to 420) °C
a 8
b 8
1.8 mΩ - 0.22µΩ/Ω
0.094 %
0.046 %
1.8 mΩ + 0.25µΩ/Ω
0.095 %
0.026 %
Bath,
drywell
calibrator,
meter,
SPRT | - |
| 23 | - | Temperature; Frequency; Timers; Photo TachometerShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0935.10) Revised 03/24/2026 Page 23 of 24
Parameter/Equipment
Range
CMC2 (±)
Comments
Temperature
3 –
Infrared
Thermometers
(10 to 300) °C
0.030 % IV + 1.2 °C
Black body
calibrator
Ɛ = 0.99,
λ = (8 to
14) µm
IV =
indicated
value
VII. Time & Frequency
Parameter/Equipment
Range
CMC
2, 7 (±)
Comments
Frequency
3 –
Measure
Measuring
Equipment
Up to Hz to 8.7 MHz
(>8.7 to 87) MHz
(>87 to 250) MHz
(>250 to 870) MHz
>870 MHz to 40 GHz
1 Hz to 50 GHz
(6.8 x 10
-11 Hz x f ) + 1.1 µHz
(6.8 x 10-10 Hz x f ) Hz
(3.3 x 10-11 Hz x f ) - 23 mHz
(6.8 x 10-11 Hz x f ) - 160 mHz
(6.8 x 10-11 Hz x f ) + 590 mHz
5.9 x 10
-12 Hz x f
GPS receiver,
counter
GPS receiver,
signal
generator
f = frequency
in Hz
Timers
3 – Measure
Up to 9:59:59.999 hr
5.6 x 10-7/sec + 0.07 ms
Function
generator,
counter
Photo Tachometer3 –
Measure
Up to 100 RPM
(>100 to 1000) RPM
(>1000 to 10 000) RPM
(>10 000 to 100 000) RPM
(>100 000 to 200 000) RPM
(0.0010 + 48 x 10
-6/R) RPM
(0.012 + 1.1 x 10-6/R) RPM
(0.045 + 2.1 x 10-6/R) RPM
(0.45 + 2.1 x 10-6/R) RPM
(0.51 + 1.5 x 10-6/R) RPM
Function
generator
with lamp
R = Reading
in RPM | - |
| 24 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 0935.10) Revised 03/24/2026 Page 24 of 24
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Rotational Speed
3 –
Measure
(Up to 100) RPM
(>100 to 1000) RPM
(>1000 to 10 000) RPM
(>10 000 to 100 000) RPM
(>100 000 to 200 000) RPM
(0.0010 + 120 x 10
-6/R) RPM
(0.0040 + 120 x 10-6/R) RPM
(0.022 + 130 x 10-6/R) RPM
(0.33 + 120 x 10-6/R) RPM
(1.0 + 110 x 10-6/R) RPM
Photo
tachometer
R = Reading in
RPM
___________________________________________
1 This laboratory offers commercial dimensional testing/calibration service and field calibration services.
2 Calibration and Measurement Capability (CMC) is th e smallest uncertainty of measurement that a
laboratory can achieve within its scope of accreditation when performing more or less routine calibrations
of nearly ideal measurement standards or nearly ideal measuring equipment. Calibration and
Measurement Capabilities represent expanded uncerta inties expressed at approximately the 95 %
confidence level, usually using a coverage factor of k = 2. The actual measurement uncertainty of a
specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the
customer’s device and to influences from the circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 The stated measured values are determined usi ng the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a
fraction/percentage of the reading plus a fixed floor specification.
5 In the statement of CMC, the value is defined as the percentage of reading unless otherwise noted.
6 This scope meets A2LA’s P112 Flexible Scope Policy.
7 The type of instrument or material being calibra ted is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
8 In the statement of CMC, L is the numerical value of the nominal length in the indicated units.
9 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for
the types of dimensional tests listed above and is considered equivalent to that of a calibration certificate. | ||
| 25 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- SIMCO Electronics - San DiegoSan Diego, CA · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Flagship Lab ServicesSan Diego, CA · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- GL TechnologiesSan Diego, CA · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- MATPHIL TECHNOLOGIES, INC. DBA ACCUTEKSan Diego, CA · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Molecular BioProducts d.b.a. Unity Lab ServicesCarlsbad, CA · ~48 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994