SIMCO Electronics - San Diego
San Diego, CA, United States
Visit website- Scope lines
- 16
- A2LA certificate
- 1
- Sites in our directory
- 3
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 16 scope lines.
A2LA certificate 1395.06 · 16 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 5 in |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.06) Revised 04/16/2025 Page 2 of 15
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Pin, Plug Gages
Up to 1 in
(25 + 4.5L) µin
Supermicrometer™, gage
blocks
Digital & Dial
Indicators3
Up to 2 in
Up to 1 in
(7.2 + 10L) µin + 0.6R
(33 + 4.5L) µin
Gage blocks & surface
plates
Supermicrometer™
End Standards
Up to 5 in
(5 to 12) in
(32 + 4.5L) µin
(38 + 4.5L) µin
Gage blocks,
Supermicrometer™
Surface Plates3 –
Flatness
Repeatability
Up to 180 in DL
Up to 0.002 in
(42 + 0.41DL) µin
49 µin
Leveling system
Repeat-o-meter
Thread Plug Gages –
Pitch Diameter
Major Diameter
(4 to 80) TPI
(0.3 to 6) mm
Up to 1 in
Up to 25.4 mm
(1 to 4) in
(25.4 to 104) mm
(65 + 7.4L) µin
(1.7 + 0.0074L) µm
(46 + 7.4L) µin
(1.2 + 0.0074L) µm
(54 + 7.4L) µin
(1.4 + 0.0074L) µm
Supermicrometer™,
gage blocks & thread
wires
Protractors &
Inclinometers³
Up to 180°
0.000 35° + 0.58R
Surface plate, gage
blocks & sine bar | to 180 ° |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.06) Revised 04/16/2025 Page 3 of 15
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range CMC2, 4, 5, 7, 8 (±) Comments
DC Voltage – Generate3
(0 to 220) mV
(0.22 to 2.2) V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
8 µV/V + 0.7 µV
7 µV/V + 1.6 µV
7 µV/V + 12 µV
7 µV/V + 13 µV
8 µV/V + 140 µV
9 µV/V + 1400 µV
Fluke 5700A/EP,
5725A
DC Voltage –
Measure
3
± (0 to 100) mV
± (0.1 to 1) V
± (1 to 10) V
± (10 to 100) V
± (100 to 1000) V*
(1000 to 10 000) V
(10 000 to 60 000) V
5.8 µV/V + 0.000 055 mV
4 µV/V + 0.000 14 mV
4 µV/V + 0.000 78 mV
6 µV/V + 0.018 mV
6 µV/V + 0.58 mV*
0.13 %
0.16 %
Agilent 3458A OPT-2
*add 12(V
in /1000)2
Parts in 106 to all Vin
>100
Ross VD60-6.2-A-
KB-AL & HP 34401A
DC Current – Generate3
Clamp Meters to
1000 A
(20 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(2.2 to 11) A
(11 to 20.5) A
(10 to 100) A
(20.5 to 1000) A
50 µA/A + 8.2 nA
50 µA/A + 43 nA
50 µA/A + 420 nA
60 µA/A + 4.4 µA
80 µA/A + 74 µA
0.036 % + 530 µA
0.078 % + 590 µA
0.06 %
0.51 % + 0.75 A
Fluke 5700A/EP,
5725A
Fluke
5520A/SC1100
L&N 4361 & Agilent
3458A
Fluke 5500A/coil &
5520A/SC1100 | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.06) Revised 04/16/2025 Page 4 of 15
Parameter/Equipment
Range
CMC2, 5, 7, 8 (±)
Comments
DC Current – Measure3
(0 to 100) nA
(0.1 to 1) µA
(1 to 10) µA
(10 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(1 to 10) A
(10 to 100) A
30 µA/A + 70 pA
20 µA/A + 70 pA
20 µA/A + 120 pA
20 µA/A + 0.8 µA
20 µA/A + 5 nA
20 µA/A + 50 nA
35 µA/A + 0.5 µA
110 µA/A + 10 µA
0.05 %
0.07 %
Agilent 3458A OPT-2
Valhalla 2575A &
Agilent 3458A OPT-2
Resistance – Measure3
(0 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(0.1 to 1.0) GΩ
15 µΩ/Ω + 52 µΩ
12 µΩ/Ω + 0.51 mΩ
10 µΩ/Ω + 0.56 mΩ
10 µΩ/Ω + 5.8 mΩ
10 µΩ/Ω + 62 mΩ
15 µΩ/Ω + 2.2 Ω
50 µΩ/Ω + 100 Ω
0.05 % + 1.4 kΩ
0.50 % + 11 kΩ
Agilent 3458A OPT-2
Resistance – Generate3,
Fixed Points
0 Ω
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
51 µΩ
95 µΩ/Ω + 12 µΩ
95 µΩ/Ω + 20 µΩ
28 µΩ/Ω + 43 µΩ
27 µΩ/Ω + 80 µΩ
17 µΩ/Ω + 290 µΩ
17 µΩ/Ω + 560 µΩ
13 µΩ/Ω + 2300 µΩ
13 µΩ/Ω + 4500 µΩ
12 µΩ/Ω + 36 000 µΩ
12 µΩ/Ω + 43 mΩ
14 µΩ/Ω + 640 mΩ
14 µΩ/Ω + 1200 mΩ
20 µΩ/Ω + 6200 mΩ
21 µΩ/Ω + 12 000 mΩ
40 µΩ/Ω + 190 000 mΩ
47 µΩ/Ω + 360 Ω
0.011 % + 2200 Ω
Fluke 5700A/EP | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.06) Revised 04/16/2025 Page 5 of 15
Parameter/Equipment
Range
CMC2, 4, 8 (±)
Comments
Resistance – Generate3
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
(0.33 to 1.1) kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
(0.33 to 1.1) MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(0.33 to 1.1) GΩ
31 µΩ/Ω + 1.1 mΩ
23 µΩ/Ω + 1.9 mΩ
22 µΩ/Ω + 2.2 mΩ
22 µΩ/Ω + 4.1 mΩ
22 µΩ/Ω + 18 mΩ
22 µΩ/Ω + 44 mΩ
22 µΩ/Ω + 140 mΩ
22 µΩ/Ω + 430 mΩ
22 µΩ/Ω + 1300 mΩ
25 µΩ/Ω + 7.7 Ω
25 µΩ/Ω + 22 Ω
47 µΩ/Ω + 140 Ω
0.01 % + 770 Ω
0.019 % + 3.7 kΩ
0.039 % + 35 kΩ
0.23 % + 80 kΩ
1.2 % + 2600 kΩ
Fluke 5520A/SC1100
Electrical Simulation of
Thermocouples
Indicating Devices –
Generate & Measure
3
Type E
Type J
Type K
Type T
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.39 °C
0.14 °C
0.12 °C
0.14 °C
0.17 °C
0.22 °C
0.14 °C
0.12 °C
0.14 °C
0.19 °C
0.27 °C
0.16 °C
0.14 °C
0.21 °C
0.32 °C
0.50 °C
0.20 °C
0.14 °C
0.12 °C
Fluke 5520A/SC1100 | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.06) Revised 04/16/2025 Page 6 of 15
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Electrical Simulation of
RTD3 – Pt 385, 100 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
0.13 °C
0.10 °C
0.13 °C
0.11 °C
0.15 °C
0.15 °C
0.25 °C
Fluke 5520A/SC1100
Oscilloscopes3 –
Leveled Sine Wave:
5 mV to 5.5 V(p-p)
Leveled Sine Flatness:
5 mV to 5.5 V(p-p)
Relative to 50 kHz
Reference
DC Signal:
50 Ω, (0.01 to 10) kHz
1 MΩ, (0.01 to 10) kHz
Square Wave Signal:
50 Ω, (0.01 to 10) kHz
1 MΩ, (1 to 10) kHz
Time Marker Output:
Into 50 Ω
Pulse Rise Time –
Generate:
Rep Rate: 1 kHz to 10
MHz
50 kHz reference
(0.05 to 100) MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
(1 to 24.999) mV
(25 to 109.99) mV
110 mV to 2.1999 V
(2.2 to 10.999) V
(1 to 24.999) mV
(25 to 109.99) mV
110 mV to 2.1999 V
(2.2 to 10.999) V
(11 to 130) V
1 mV to 6.599 V(p-p)
1 mV to 130 V(p-p)
2 ns to 20 ms
50 ms to 5 s
<350 ps
1.8 % + 250 µV
1.8 % + 110 µV
2 % + 110 µV
3.4 % + 110 µV
4.1 % + 110 µV
0.049 mV + 40 µV
0.21 mV + 40 µV
0.0043 V + 40 µV
0.021 V to 40 µV
0.015 mV + 40 µV
0.047 mV + 40 µV
0.000 89 V + 40 µV
0.0046 V + 40 µV
0.052 V + 40 µV
0.19 % + 40 µV
0.078 % + 40 µV
11 x 10
6 s
120 x 106 s
85 ps
Fluke 5520A/SC1100,
See RF power/flatness
– generate for
oscilloscopes above
1 GHz | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.06) Revised 04/16/2025 Page 7 of 15
Parameter/Range
Frequency
CMC2, 4, 5, 7, 8 (±)
Comments
AC Current – Measure3
(10 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(1 to 2) A
(>2 to 100) A
45 Hz to 1 kHz
(45 to 100) Hz
(0.1 to 5) kHz
(45 to 100) Hz
(0.1 to 5) kHz
(45 to 100) Hz
(0.1 to 5) kHz
(45 to 100) Hz
(0.1 to 5) kHz
(0.4 to 1) kHz
(0.4 to 1) kHz
0.069 % + 0.035 µA
0.069 % + 230 nA
0.035 % + 230 nA
0.069 % + 2.3 µA
0.035 % + 2.3 µA
0.069 % + 23 µA
0.035 % + 23 µA
0.092 % + 240 µA
0.12 % + 240 µA
0.042 %
0.12 %
Agilent 3458A
OPT-2
Valhalla Scientific
2575A & Agilent
3458A
AC Current – Generate3
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(2.2 to 11) A
(33 to 330) µA
(11 to 20.5) A
(10 to 100) A
(>40 to 1000) Hz
(1 to 5) kHz
(>40 to 1000) Hz
(1 to 5) kHz
(>40 to 1000) Hz
(1 to 5) kHz
(>40 to 1000) Hz
(1 to 5) kHz
(>40 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(>45 to 1000) Hz
(1 to 5) kHz
(>0.1 to 1) kHz
(1 to 5) kHz
(10 to 60) Hz
0.014 % + 53 nA
0.06 % + 400 nA
0.014 % + 810 nA
0.06 % + 4100 nA
0.014 % + 7.9 µA
0.06 % + 41 µA
0.065 % + 87 µA
0.075 % + 110 µA
0.046 % + 710 µA
0.095 % + 780 µA
0.36 % + 1000 µA
0.099 % + 0.078 µA
0.23 % + 0.12 µA
0.12 % + 3.9 mA
2.3 % + 3.9 mA
0.12 %
Fluke 5700A/EP,
5725A
Fluke
5520A/SC1100
LCOMP OFF
Valhalla 2575A,
Agilent 3458A | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.06) Revised 04/16/2025 Page 8 of 15
Parameter/Range
Frequency
CMC2, 5, 7 (±)
Comments
AC Current – Generate3
(cont)
Clamp Meters to 1000 A
(20.5 to 1000) A
(45 to 400) Hz
1.5 % + 0.36 A
Fluke 5500A/coil
& 5520A/SC1100
LCOMP OFF
AC Voltage – Generate3
(0.22 to 2.2) mV
(2.2 to 22) mV
(22 to 220) mV
(0.22 to 2.2) V
(2.2 to 22) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
0.055 % + 5 µV
0.021 % + 5 µV
0.011 % + 5 µV
0.037 % + 5.4 µV
0.085 % + 8 µV
0.11 % + 15 µV
0.17 % + 27 µv
0.34 % + 28 µV
0.055 % + 8 µV
0.021 % + 7 µV
0.011 % + 12 µV
0.037 % + 12 µV
0.085 % + 11 µV
0.11 % + 20 µV
0.17 % + 32 µV
0.34 % + 42 µV
0.055 % + 21 µV
0.021 % + 18 µV
0.011 % + 11 µV
0.032 % + 17 µV
0.085 % + 41 µV
0.11 % + 55 µV
0.17 % + 78 µV
0.34 % + 190 µV
0.05 % + 140 µV
0.016 % + 49 µV
0.0075 % + 42 µV
0.012 % + 78 µV
0.025 % + 130 µV
0.043 % + 330 µV
0.11 % + 560 µV
0.22 % + 1700 µV
0.05 % + 1.4 mV
0.016 % + 0.54 mV
0.0075 % + 0.48 mV
0.012 % + 0.8 mV
0.025 % + 1.3 mV
0.05 % + 3.7 mV
Fluke 5700A/EP &
5725A | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.06) Revised 04/16/2025 Page 9 of 15
Parameter/Range
Frequency
CMC2, 5, 7 (±)
Comments
AC Voltage – Generate3
(cont)
(2.2 to 22) V
(22 to 220) V
(220 to 1100) V
(250 to 750) V
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(15 to 50) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 30) kHz
(30 to 50) kHz
(50 to 100) kHz
0.13 % + 7.7 mV
0.27 % + 21 mV
0.05 % + 14 mV
0.016 % + 6.5 mV
0.008 % + 6.1 mV*
0.022 % + 12 mV
0.05 % + 18 mV
0.04 % + 42 mV
0.008 % + 39 mV
0.017 % + 12 mV
0.06 % + 16 mV
0.06 % + 42 mV
0.23 % + 100 mV
Fluke 5700A/EP &
5725A
*Subject to 2.2 x
107 V Hz limitation
AC Voltage – Measure3
(1 to 10) mV
(10 to 100) mV
(0.1 to 1) V
(1 to 10) V
(1 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
0.035 % + 3.5 µV
0.023 % + 1.3 µV
0.035 % + 1.3 µV
0.12 % + 1.3 µV
0.58 % + 1.3 µV
4.6 % + 2.3 µV
0.0081 % + 5.2 µV
0.0081 % + 3.3 µV
0.016 % + 3.2 µV
0.035 % + 3.2 µV
0.092 % + 3.2 µV
0.35 % + 12 µV
1.2 % + 13 µV
0.0081 % + 48 µV
0.0081 % + 26 µV
0.016 % + 24 µV
0.035 % + 28 µV
0.092 % + 30 µV
0.35 % + 120 µV
1.2 % + 280 µV
0.0081 % + 0.50 mV
0.0081 % + 0.27 mV
0.016 % + 0.27 mV
0.035 % + 0.31 mV
0.092 % + 0.32 mV
0.35 % + 1.2 mV
1.2 % + 3.1 mV
Agilent 3458A
OPT-2 | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.06) Revised 04/16/2025 Page 10 of 15
Parameter/Range
Frequency
CMC2, 5, 8 (±)
Comments
AC Voltage – Measure3
(cont)
(10 to 100) V
(100 to 700) V
(700 to 10 000) V
(10 000 to 42 000) V
(1 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(1 to 40) Hz
(0.04 to 20) kHz
(50 to 60) Hz
(50 to 60) Hz
0.023 % + 4.8 mV
0.023 % + 2.7 mV
0.023 % + 2.8 mV
0.04 % + 3.1 mV
0.14 % + 3.7 mV
0.046 % + 48 mV
0.069 % + 27 mV
0.60 %
0.62 %
Agilent 3458A
OPT-2
Ross VD60-6.2-A-
KB-AL & HP
34401A
Capacitance – Generate3
2-Wire
(0.19 to <3.3) nF
(3.3 to <11) nF
(11 to 110) nF
(110 to <330) nF
(0.33 to <1.1) µF
(1.1 to <3.3) µF
(3.3 to <11) µF
(11 to <33) µF
(33 to <110) µF
(110 to <330) µF
(0.33 to <1.1) mF
(1.1 to <3.3) mF
(3.3 to <11) mF
(11 to <33) mF
(33 to <110) mF
(0.01 to 10) kHz
(0.01 to 1) kHz
(0.01 to 1) kHz
(0.01 to 1) kHz
(10 to 600) kHz
(10 to 300) kHz
(10 to 150) Hz
(10 to 120) Hz
(10 to 80) Hz
(10 to 50) Hz
(0 to 20) Hz
(0 to 6) Hz
(0 to 2) Hz
(0 to 0.6) Hz
(0 to 0.2) Hz
0.58 % + 13 pF
0.29 % + 13 pF
0.29 % + 150 pF
0.29 % + 510 pF
0.29 % + 1.2 nF
0.29 % + 6.8 nF
0.29 % + 13 nF
0.46 % + 55 nF
0.52 % + 130 nF
0.52 % + 350 nF
0.52 % + 1.2 µF
0.52 % + 3.5 µF
0.52 % + 12 µF
0.87 % + 35 µF
1.3 % + 120 µF
Fluke 5520A/
SC1100 | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.06) Revised 04/16/2025 Page 11 of 15
III. Electrical – RF/Microwave
Parameter/Range
Frequency CMC2, 10 (±) Comments
RF Power3 – Generate
(+20 to -100) dBm
(<-100 to -127) dBm
9 kHz to 3200 MHz
(>3200 to 4000) MHz
(9 to <100) kHz
(0.1 to 2500) MHz
(>2500 to 4000) MHz
1.2 dB
2.3 dB
3.5 dB
1.2 dB
3.5 dB
HP 8648D OPT-1E2, 1E5,
1EA
HP 8648D OPT-1E2, 1E5,
1EA
RF Power/Flatness3 –
Generate
(+20 to -20) dBm
(100 to 300) kHz
(0.3 to 1) MHz
(0.001 to 4.2) GHz
0.2 dB
0.19 dB
0.19 dB
HP 8648D, 11667B, 8482A
& E4419B
RF Power3 – Measure
(+20 to -20) dBm
(100 to 300) kHz
(0.3 to 1) MHz
(0.001 to 4.2) GHz
0.083 dB
0.068 dB
0.067 dB
HP 8482A & E4419B
Distortion3 – Measure
≤ -80 dB
≤ -65 dB
20 Hz to 20 kHz
(20 to 100) kHz
1.2 dB
2.3 dB
HP 8903B
IV. Mechanical
Parameter/Equipment
Range
CMC2, 6, 8 (±)
Comments
Scales & Balances3
(1 to 50) mg
2 g
20 g
50 g
100 g
(0.2 to 10) kg
(10 to 20) kg
(20 to 35) kg
Up to 500 lb
0.0059 mg + 0.58R
0.04 mg + 0.58R
0.052 mg + 0.58R
0.086 mg + 0.58R
0.15 mg + 0.58R
0.000 29 % + 0.58R
83 mg + 0.58R
88 mg + 0.58R
0.18 % + 0.58R
Ultra Class weights
Class 1 weights
Class F weights | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.06) Revised 04/16/2025 Page 12 of 15
Parameter/Equipment
Range
CMC2, 6, 8, 10 (±)
Comments
Torque Wrenches &
Screwdrivers3 –
Measure
(5 to 50) ozfꞏin
(1 to 10) lbfꞏin
(10 to 50) lbfꞏin
(50 to 250) lbfꞏin
(15 to 150) lbfꞏft
(150 to 1000) lbfꞏft
0.75 % + 0.58R
0.6 % + 0.58R
0.65 % + 0.58R
0.68 % + 0.58R
0.67 % + 0.58R
0.64 % + 0.58R
AWS torque system
Torque Transducers &
Analyzers – Measuring
Equipment3
(0 to 250) lbf∙in
0.11 % + 0.58R
Class F weights & torque
wheels
Force3 – Measuring
Equipment, Tension &
Compression
(0 to 300) lbf
0.031 % + 0.58R
Class F weights
Pressure & Vacuum3 –
Measuring Equipment
(0.9 to 3.16) psia
(3.16 to 7.53) psia
(7.53 to 23) psia
(23 to 97) psia
(97 to 300) psia
(-14.7 to -12.3) psig
(-12.3 to -7.9) psig
(-7.9 to 8) psig
(8 to 86.7) psig
(86.7 to 300) psig
(300 to 1000) psig
(1000 to 10 000) psig
(2 to 10 000) psi
0.000 38 psia + 0.58R
0.011 % + 0.58R
0.012 % + 0.58R
0.01 psia + 0.58R
0.011 % + 0.58R
0.001 psig + 0.58R
0.011 % + 0.58R
0.012 % + 0.58R
0.01 psig + 0.58R
0.012 % + 0.58R
1.2 psig + 0.58R
6.3 psig + 0.58R
0.039 % + 0.58R
Fluke PPC4
Druck DPI705
Pressurements M2200-3-P
Pipettes
(2 to 10) µL
(10 to 100) µL
(100 to 500) µL
(500 to 1000) µL
(1000 to 5000) µL
0.099 µL
0.37 µL
0.55 µL
1.6 µL
2 µL
Gravimetric calibration
using A&D AD-4212B-PT
& Mettler AT200 | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.06) Revised 04/16/2025 Page 13 of 15
V. Thermodynamic
Parameter/Equipment
Range
CMC2, 6, 10 (±)
Comments
Temperature –
Measuring Equipment3
(-70 to 100) oC
(100 to 175) oC
(-5 to 100) oC
(100 to 125) oC
(-15 to 350)
oC
0.028 oC + 0.58R
0.026 oC + 0.58R
0.035
oC + 0.58R
0.068 oC + 0.58R
0.12
oC + 0.58R
Hart Scientific 1502A, 5628
w/ environmental chamber
Hart Scientific 1502A, 5628
w/ oil bath
Hart Scientific 1502A, 5628
w/ drywell
Temperature – Measure3
(-196 to 0) oC
(0 to 100) oC
(100 to 500) oC
0.025 oC
0.013 oC
0.024 oC
Hart Scientific 1502A, 5628
Relative Humidity –
Measuring Equipment
3
(10 to 76) % RH
(0 to 40) oC
1.9 % RH
Vaisala HM40/HM46 w/
humidity chamber
Relative Humidity –
Measure3
(10 to 90) % RH
(90 to 95) % RH
1.9 % RH
3.0 % RH
Vaisala HM40/HM46
VI. Time & Frequency
Parameter/Equipment
Range CMC2, 6, 10 (±) Comments
Timers & Stopwatches3
Up to 86 400 s
Totalize
Stopwatch to
Stopwatch
(0 to 19.99) s/day
64 ms
84 ms
0.038 s/day
HP 53132A, HP 33220A
phase locked to GPS
Stopwatch comparison
Timometer
Frequency Reference
10 MHz
1.5 pHz/Hz + 0.58R
Fluke 910R GPS
Frequency – Measuring
Equipment3
0.01 Hz to 600 MHz
9 kHz to 4 GHz
1.5 pHz/Hz + 0.58R
30 pHz/Hz + 0.58R
Fluke 910R GPS & HP
53132A
HP 8648D phase locked to
GPS | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.06) Revised 04/16/2025 Page 14 of 15
Parameter/Equipment
Range CMC2, 6, 8,. 10 (±) Comments
Frequency3 – Measure
0.1 Hz to 3 GHz
1.5 pHz/Hz + 0.58R
Fluke 910R GPS & HP
53132A
RPM – Measure
(0 to 100 000) rpm
0.012 % + 0.58R
Monarch PLT200
Tachometers
(10 to 200 000) rpm
1.9 µrpm/rpm + 0.58R
HP 33220A phase locked to
GPS
________________________________________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 Based on using the standard at the temperature the Fluke 5520A with SC1100 was calibrated (tcal ± 5 oC)
and assuming the instrument is zeroed at least every seven days or when the ambient temperature changes
more than 5 oC. For resistance, a zero calibration is performed at least every 12 hours within ± 1 oC of
use. For AC Current, CMC are determined with LCOMP Off. CMC is based upon 1-year specifications
and is read as ppm (parts per million) or percent output plus floor specification where defined.
5 Based on using the standard at the temperature the Agilent 3458A was calibrated (tcal ± 5 oC) and an auto-
calibration (ACAL) was performed within the previous 24 hours (± 1 oC of ambient temperature). CMC
is based upon 1- year specifications and is read as ppm (parts per million) or percent output plus floor
specification where defined.
6 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches;
R is the numerical value of the resolution of the device , DL is the diagonal length of the surface plate
measured in inches.
7 Based on using the Fluke 5700A/5725A within 5 oC of the temperature noted at the time of cal (tcal ± 5
oC) and assuming the zero calibrat ion is performed every 30 days. CMC is based upon 1- year
specifications and is read as ppm (parts per million, µV/V) or percent of output plus floor specification
where defined. Includes stability. Resistance specifications apply only to the displayed resistance value
using 4-wire configuration (except for 100 MΩ). Uncertainty specifications for 220 mA and 2.2 mA
ranges are increased by a factor of 1.3 when supplied through 5725A terminals. | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.06) Revised 04/16/2025 Page 15 of 15
8 When percent (%) is present in the statement of CMC; the value is defined as the percentage of reading
unless otherwise noted.
9 This scope meets A2LA’s P112 Flexible Scope Policy.
10 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 16 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Other Locations
2 other sites in this organization
Labs with overlapping accredited scope in United States
- Aalberts IPSAPageland, SCA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- AALFA - KAL Metrology Laboratory, division of AALBORG Instruments & ControlsOrangeburg, NYA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- ACR Technical ServicesNewport News, VAA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994