United States

Aldinger Company DBA Quality Control Services

Milwaukie, OR, United States

Visit website
A2LA 1550.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
8
A2LA certificate
1
Sites in our directory
3
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 8 scope lines.

A2LA certificate 1550.01 · 8 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994pH; mV; µS/cm; % DO-
2-Formazin nephelometric turbidity unit standards; Accredited refractive index standards; Spectronic glass filter standards
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1550.01) Revised 6/11/2026 Page 2 of 7 Parameter/Equipment Range CMC2, 4 (±) Comments Turbidimeters3 (< 0.1 to 1) NTU (1 to 20) NTU (21 to 200) NTU (201 to 1000) NTU (1001 to 4000) NTU 0.083 NTU 0.87 NTU 2.2 NTU 5.0 NTU 21 NTU Formazin nephelometric turbidity unit standards Refractometers3 1.3330 nD 1.399 86 nD 1.468 39 nD 0 % Brix 40 % Brix 70 % Brix 0.000 45 nD 0.000 43 nD 0.000 41 nD 0.33 % Brix 0.23 % Brix 0.17 % Brix nD is a unit for refractive index % Brix is a unit for refractive index specific to sugar solutions Accredited refractive index standards Spectrophotometers3 Transmittance at (440 to 635) nm Wavelength 10 % T 50 % T 400 nm peak 525 nm peak 780 nm peak 0.11 % T 0.60 % T 0.76 nm 0.76 nm 0.98 nm Spectronic glass filter standards T = transmittance II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouple Indicators – Type J Type K Type S Type T (-200 to 800) °C (-200 to 1300) °C (0 to 1500) °C (-200 to 400) °C 0.31 °C 0.32 °C 0.38 °C 0.40 °C Fluke 702 / 726 process calibrator
-
3-air; volumetric apparatus; balances and scales
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1550.01) Revised 6/11/2026 Page 3 of 7 III. Fluid Quantities Parameter/Equipment Range CMC2 (±) Comments Fume Hoods – Air Velocity Only3 (60 to 120) ft/min 19 ft/min Extech 407119A anemometer Volumetric Apparatus3 – Including But Not Limited To: Pipettes, Syringes, Dispensers, & Burettes (0.1 to 0.5) µL (0.5 to 2.5) µL (2.5 to 5) µL (5 to 10) µL (10 to 100) µL (100 to 500) µL (500 to 1000) µL (1000 to 2500) µL (2500 to 5000) µL (5 to 10) mL (10 to 25) mL (25 to 50) mL 0.061 µL 0.050 µL 0.065 µL 0.054 µL 0.16 µL 0.73 µL 0.99 µL 1.4 µL 3.3 µL 9.4 µL 9.6 µL 12 µL Gravimetric method using: analytical balances / precision balances IV. Mechanical Parameter/Equipment Range CMC2, 5 (±) Comments Balances and Scales3 (1 to 3) mg (> 3 to 50) mg (> 50 to 100) mg (> 100 to 200) mg (> 200 to 500) mg > 500 mg to 3 g (> 3 to 5) g (> 5 to 10) g (> 10 to 30) g (> 30 to 50) g (> 50 to 100) g (> 100 to 200) g (> 200 to 300) g (> 300 to 400) g (> 400 to 500) g > 500 g to 1 kg (> 1 to 2) kg (> 2 to 3) kg (> 3 to 5) kg (> 5 to 10) kg (> 10 to 30) kg (> 30 to 50) kg 0.000 73 mg 0.000 86 mg 0.0013 mg 0.0030 mg 0.0032 mg 0.0057 mg 0.0075 mg 0.010 mg 0.017 mg 0.031 mg 0.064 mg 0.077 mg 0.14 mg 0.16 mg 0.59 mg 0.76 mg 1.3 mg 1.8 mg 2.4 mg 9.3 mg 82 mg 83 mg ASTM Class 1 weights
See scope document
4NIST.IR.5672; NIST.IR.6969-See scope document
5NIST.IR.5672; NIST.IR.6969mass; thermometers; temperature sensors; liquid-in-glass thermometers; RTD and thermistor sensors; thermocouple thermometersSee scope document
6-Freezers, Refrigerators, Cold Boxes, Incubators, Environmental Chambers, Water Baths, Autoclaves, Hot Plates, Furnaces, & Ovens
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1550.01) Revised 6/11/2026 Page 6 of 7 Parameter/Equipment Range CMC2, 8 (±) Comments Infrared (IR) Thermometers (-15 to < 0) °C (0 to < 50) °C (50 to < 100) °C (100 to 120) °C (> 120 to 200) °C (> 200 to 350) °C (> 350 to 500) °C 0.94 °C 0.74 °C 0.44 °C 0.96 °C 1.5 °C 2.7 °C 4.0 °C Fluke 4180 IR calibrator Fluke 4181 IR calibrator Temperature Measure3 – Including But Not Limited To: Freezers, Refrigerators, Cold Boxes, Incubators, Environmental Chambers, Water Baths, Autoclaves, Hot Plates, Furnaces, & Ovens (-80 to -1) °C (0 to 150) °C (151 to 400) °C (401 to 600) °C (601 to 1000) °C 0.33 °C 0.29 °C 0.79 °C 3.7 °C 8.1 °C Digital Thermometer Relative Humidity3 – Measure Thermo Hygrometers (40 to 60) % RH (15 to 25) °C 1.2 % RH 0.09 °C Fluke 1620A meter with 2626H sensor ____________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the Calibration and Measurement Capability Uncertainty (CMC) found on t he A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 For the parameter Dissolved Oxygen, DO represents “Dissolved Oxygen” and for the parameter Turbidity, NTU represents Nephelometric Turbidity Units.
See scope document
7-Analytical and Precision Balances, Scales and Moisture Analyzers and Moisture Balances
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1550.01) Revised 6/11/2026 Page 7 of 7 5 For the parameters Analytical and Precision Balances, Scales and Moisture Analyzers and Moisture Balances, R represents the numerical value of the resolution of the device. 6 English/Avoirdupois Mass values will be determined using accepted international conversion factors. 7 CMC uncertainties based on total immersion thermometers. 8 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 9 This scope meets A2LA’s P112 Flexible Scope Policy.
-
8ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Other Locations

2 other sites in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.