Aldinger Company DBA Quality Control Services
Milwaukie, OR, United States
Visit website- Scope lines
- 8
- A2LA certificate
- 1
- Sites in our directory
- 3
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 8 scope lines.
A2LA certificate 1550.01 · 8 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | pH; mV; µS/cm; % DO | - |
| 2 | - | Formazin nephelometric turbidity unit standards; Accredited refractive index standards; Spectronic glass filter standardsShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1550.01) Revised 6/11/2026 Page 2 of 7
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Turbidimeters3
(< 0.1 to 1) NTU
(1 to 20) NTU
(21 to 200) NTU
(201 to 1000) NTU
(1001 to 4000) NTU
0.083 NTU
0.87 NTU
2.2 NTU
5.0 NTU
21 NTU
Formazin nephelometric
turbidity unit standards
Refractometers3
1.3330 nD
1.399 86 nD
1.468 39 nD
0 % Brix
40 % Brix
70 % Brix
0.000 45 nD
0.000 43 nD
0.000 41 nD
0.33 % Brix
0.23 % Brix
0.17 % Brix
nD is a unit for refractive
index
% Brix is a unit for
refractive index specific
to sugar solutions
Accredited refractive
index standards
Spectrophotometers3
Transmittance at
(440 to 635) nm
Wavelength
10 % T
50 % T
400 nm peak
525 nm peak
780 nm peak
0.11 % T
0.60 % T
0.76 nm
0.76 nm
0.98 nm
Spectronic glass filter
standards
T = transmittance
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
Thermocouple
Indicators –
Type J
Type K
Type S
Type T
(-200 to 800) °C
(-200 to 1300) °C
(0 to 1500) °C
(-200 to 400) °C
0.31 °C
0.32 °C
0.38 °C
0.40 °C
Fluke 702 / 726 process
calibrator | - |
| 3 | - | air; volumetric apparatus; balances and scalesShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1550.01) Revised 6/11/2026 Page 3 of 7
III. Fluid Quantities
Parameter/Equipment
Range
CMC2 (±)
Comments
Fume Hoods – Air
Velocity Only3
(60 to 120) ft/min
19 ft/min
Extech 407119A
anemometer
Volumetric Apparatus3 –
Including But Not
Limited To: Pipettes,
Syringes, Dispensers,
& Burettes
(0.1 to 0.5) µL
(0.5 to 2.5) µL
(2.5 to 5) µL
(5 to 10) µL
(10 to 100) µL
(100 to 500) µL
(500 to 1000) µL
(1000 to 2500) µL
(2500 to 5000) µL
(5 to 10) mL
(10 to 25) mL
(25 to 50) mL
0.061 µL
0.050 µL
0.065 µL
0.054 µL
0.16 µL
0.73 µL
0.99 µL
1.4 µL
3.3 µL
9.4 µL
9.6 µL
12 µL
Gravimetric method
using: analytical balances
/ precision balances
IV. Mechanical
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Balances and Scales3
(1 to 3) mg
(> 3 to 50) mg
(> 50 to 100) mg
(> 100 to 200) mg
(> 200 to 500) mg
> 500 mg to 3 g
(> 3 to 5) g
(> 5 to 10) g
(> 10 to 30) g
(> 30 to 50) g
(> 50 to 100) g
(> 100 to 200) g
(> 200 to 300) g
(> 300 to 400) g
(> 400 to 500) g
> 500 g to 1 kg
(> 1 to 2) kg
(> 2 to 3) kg
(> 3 to 5) kg
(> 5 to 10) kg
(> 10 to 30) kg
(> 30 to 50) kg
0.000 73 mg
0.000 86 mg
0.0013 mg
0.0030 mg
0.0032 mg
0.0057 mg
0.0075 mg
0.010 mg
0.017 mg
0.031 mg
0.064 mg
0.077 mg
0.14 mg
0.16 mg
0.59 mg
0.76 mg
1.3 mg
1.8 mg
2.4 mg
9.3 mg
82 mg
83 mg
ASTM Class 1 weights | See scope document |
| 4 | NIST.IR.5672; NIST.IR.6969 | - | See scope document |
| 5 | NIST.IR.5672; NIST.IR.6969 | mass; thermometers; temperature sensors; liquid-in-glass thermometers; RTD and thermistor sensors; thermocouple thermometers | See scope document |
| 6 | - | Freezers, Refrigerators, Cold Boxes, Incubators, Environmental Chambers, Water Baths, Autoclaves, Hot Plates, Furnaces, & OvensShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1550.01) Revised 6/11/2026 Page 6 of 7
Parameter/Equipment
Range
CMC2, 8 (±)
Comments
Infrared (IR) Thermometers
(-15 to < 0) °C
(0 to < 50) °C
(50 to < 100) °C
(100 to 120) °C
(> 120 to 200) °C
(> 200 to 350) °C
(> 350 to 500) °C
0.94 °C
0.74 °C
0.44 °C
0.96 °C
1.5 °C
2.7 °C
4.0 °C
Fluke 4180 IR calibrator
Fluke 4181 IR calibrator
Temperature Measure3 –
Including But Not Limited
To: Freezers, Refrigerators,
Cold Boxes, Incubators,
Environmental Chambers,
Water Baths, Autoclaves,
Hot Plates, Furnaces, &
Ovens
(-80 to -1) °C
(0 to 150) °C
(151 to 400) °C
(401 to 600) °C
(601 to 1000) °C
0.33 °C
0.29 °C
0.79 °C
3.7 °C
8.1 °C
Digital Thermometer
Relative Humidity3 –
Measure
Thermo Hygrometers
(40 to 60) % RH
(15 to 25) °C
1.2 % RH
0.09 °C
Fluke 1620A meter with
2626H sensor
____________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the Calibration and
Measurement Capability Uncertainty (CMC) found on t he A2LA Scope. Allowance must be made for
aspects such as the environment at the place of calibration and for other possible adverse effects such as
those caused by transportation of the calibration equipment. The usual allowance for the uncertainty
introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own,
could result in the actual measurement uncertainty achievable on a customer’s site being larger than the
CMC.
4 For the parameter Dissolved Oxygen, DO represents “Dissolved Oxygen” and for the parameter Turbidity,
NTU represents Nephelometric Turbidity Units. | See scope document |
| 7 | - | Analytical and Precision Balances, Scales and Moisture Analyzers and Moisture BalancesShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1550.01) Revised 6/11/2026 Page 7 of 7
5 For the parameters Analytical and Precision Balances, Scales and Moisture Analyzers and Moisture
Balances, R represents the numerical value of the resolution of the device.
6 English/Avoirdupois Mass values will be determined using accepted international conversion factors.
7 CMC uncertainties based on total immersion thermometers.
8 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
9 This scope meets A2LA’s P112 Flexible Scope Policy. | - |
| 8 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Other Locations
2 other sites in this organization
Labs with overlapping accredited scope in United States
- Aalberts IPSAPageland, SCA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- AALFA - KAL Metrology Laboratory, division of AALBORG Instruments & ControlsOrangeburg, NYA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- ACR Technical ServicesNewport News, VAA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- AH Electronic Test Equipment Repair CenterIslip, NYA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- All American Scales & CalibrationParis, OHA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.