Parametric
4065 E La Palma Ave, Suite C, 92807, Anaheim, CA, United States
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 3865.01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3865.01) 05/23/2025 Page 1 of 3
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
PARAMETRIC, INC.
4065 E La Palma Ave, Suite C
Anaheim, CA 92807
Drew Harris Phone: 714 694 6500
CALIBRATION
Valid To: March 31, 2027 Certificate Number: 3865.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 5:
I. Chemical
II. Mechanical
Parameter
Range
CMC2, 4 (±)
Comments
Conductivity –
Measuring Equipment,
Fixed Points3
1 μS
10 μS
100 μS
1413 μS
10 004 μS
0.33 μS
0.41 μS
1.0 μS
5.8 μS
36 μS
Standard conductivity
solution
pH – Measuring
Equipment, Fixed
Points
3
4.0 pH
7.0 pH
10.0 pH
0.011 pH
0.012 pH
0.012 pH
Standard pH buffer solution
Parameter
Range
CMC2, 4 (±)
Comments
Non-Contact
Tachometer
Up to 50 RPM
(50 to 500) RPM
(500 to 5000) RPM
(5000 to 50 000) RPM
(50 000 to 200 000) RPM
0.0023 RPM
0.0034 RPM
0.014 RPM
0.13 RPM
1.3 RPM
Fluke 5522A calibrator or
equivalent | ||
| 2 | - | Measuring EquipmentShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3865.01) 05/23/2025 Page 2 of 3
Parameter
Range
CMC2, 4 (±)
Comments
Vacuum – Measuring
Equipment3
(-14.7 to 0) psi
0.0065 psi
Additel ADT760-MA
calibrator with Additel
ADT155 pressure module or
equivalent
Pressure – Measuring
Equipment3
(-20 to 20) inH2O
0.000 73 in H2O
Fluke 7250LP or equivalent
Pressure – Measuring
Equipment3
(0 to ≤35) psig
(˃35 to 300) psig
0.0061 psi
0.041 psi
Additel ADT760-MA
calibrator with Additel
ADT155 pressure module or
equivalent
III. Thermodynamics
Parameter
Range
CMC2, 4 (±)
Comments
Humidity – Measure &
Measuring Equipment3
(10 to 20) % RH
(20 to 60) % RH
(60 to 85) % RH
(85 to 95) % RH
1.2 % RH
1.4 % RH
1.5 % RH
2.1 % RH
Vaisala MI70
With HMP77B or equivalent
Temperature – Measure
& Measuring
Equipment3
(-200 to 200) °C
(200 to 420) °C
(420 to 660) °C
0.0072 °C
0.030 °C
0.040 °C
Precision thermometer with
PRT or equivalent
________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavi or of the customer’s device and to influences from the
circumstances of the specific calibration. | -14.7 to 0 psi |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3865.01) 05/23/2025 Page 3 of 3
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 4 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.