Tektronix, Inc. - N. Billerica Test
7 Sterling Road, 01862, North Billerica, MA, United States
Visit website- Accredited standards
- 14
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 14 standard numbers and the 8 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 60068 series10
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-13
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-29
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance
IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
ASTM4
ASTM D4169
ASTM D4332
ASTM D6653
ASTM D7386
MIL-STD-810C: Method 501.1; MIL-STD-810D: Method 501.2; MIL-STD-810E: Method 501.3; MIL-STD-810F: Method 501.4; MIL-STD-810G: Method 501.5; MIL-STD-810G w/ Change 1, Method 501.6; MIL-STD-810H: Method 501.7; MIL-STD-810C: Method 502.1; MIL-STD-810D: Method 502.2; MIL-STD-810E: Method 502.3; MIL-STD-810F: Method 502.4; MIL-STD-810G: Method 502.5; MIL-STD-810G w/ Change 1, Method 502.6; MIL-STD-810H: Method 502.7; IEC 60068-2-1; IEC 60068-2-2; IEC 60068-2-14; RTCA/DO-160E; RTCA/DO-160F; RTCA/DO-160G; MIL-STD-202G: Method 107; MIL-STD-750E: Method 1051; MIL-STD-810C: Method 503.1; MIL-STD-810D: Method 503.2; MIL-STD-810E: Method 503.3; MIL-STD-810F: Method 503.4; MIL-STD-810G: Method 503.5; MIL-STD-810G w/ Change 1, Method 503.6; MIL-STD-810H: Method 503.7; MIL-STD-883-1: Method 1010; RTCA/DO-160E (Section 5); RTCA/DO-160F (Section 5); RTCA/DO-160G; MIL-STD-202G: Methods 103 and 106; MIL-STD-750E: Method 1021; MIL-STD-810C: Method 507.1; MIL-STD-810D: Method 507.2; MIL-STD-810E: Method 507.3; MIL-STD-810F: Method 507.4; MIL-STD-810G: Method 507.5; MIL-STD-810G w/ Change 1, Method 507.6; MIL-STD-810H: Method 507.6; MIL-STD-202: Method 103B; MIL-STD-883-1: Method 1004; IEC 60068-2-30; IEC 60068-2-78; ISTA ASTM D4169; ISTA/ASTM D4332; RTCA/DO-160E (6.0); RTCA/DO-160F; RTCA/DO-160G; ISTA; ASTM D4169; ASTM D7386; MIL-STD-810G: Method 516
MIL-STD-883-1: Method 200; MIL-STD-202G: Method 212 TC, B, and C; MIL-STD-750E: Method 2006; MIL-STD-810C: Method 513.2; MIL-STD-810D: Method 513.3; MIL-STD-810E: Method 513.4; MIL-STD-810F: Method 513.5; MIL-STD-810G: Method 513.6; MIL-STD-810G w/ Change 1, 513.7; MIL-STD-810H: 513.8; MIL-STD-202G: Method 212A; RTCA/DO-160E; RTCA/DO-160F; RTCA/DO-160G; MIL-STD-202G: Method 105; MIL-STD-750E: Method 1001; MIL-STD-810C, Method 500.1; MIL-STD-810D, Method 500.2; MIL-STD-810E, Method 500.3; MIL-STD-810F, Method 500.4; MIL-STD-810G, Method 500.5; MIL-STD-810G w/ Change 1, 500.6; MIL-STD-810H, 500.6; IEC 60068-2-13; ASTM D4169; ASTM D6653; RTCA/DO-160E Section 4; RTCA/DO-160F; RTCA/DO-160G; MIL-STD-810C: Method 501.1; MIL-STD-810D: Method 501.2; MIL-STD-810E: Method 501.3; MIL-STD-810F: Method 501.4; MIL-STD-810G: Method 501.5; MIL-STD-810G w/ Change 1, Method 501.6; MIL-STD-810H: Method 501.7; MIL-STD-810C: Method 502.1; MIL-STD-810D: Method 502.2; MIL-STD-810E: Method 502.3; MIL-STD-810F: Method 502.4; MIL-STD-810G: Method 502.5; MIL-STD-810G w/ Change 1, Method 502.6; MIL-STD-810H: Method 502.7; IEC 60068-2-1; IEC 60068-2-2; IEC 60068-2-14
MIL-STD-810C; MIL-STD-810D; MIL-STD-810E; MIL-STD-810F; MIL-STD-810G; MIL-STD-810G w/ Change 1; MIL-STD-810H; MIL-STD-202G; MIL-STD-750E; MIL-STD-883-1; RTCA/DO-160E; RTCA/DO-160F; RTCA/DO-160G; IEC 60068-2-27; IEC 60068-2-29; IEC 60068-2-6
MIL-STD-883-1: Method 2007; RTCA/DO-160E (Section 8); RTCA/DO-160F (Section 8); RTCA/DO-160G (Section 8); MIL-STD-167-1; MIL-STD 167-1; ISTA, ASTM D4169, Fixed Displacement, Sine, and Random; IEC 60068-2-6; IEC 60068-2-64; MIL-STD-202G: Method 105; MIL-STD-750E: Method 1001; MIL-STD-810C: Method 500.1; MIL-STD-810D: Method 500.2; MIL-STD-810E: Method 500.3; MIL-STD-810F: Method 500.4; MIL-STD-810G: Method 500.5; MIL-STD-810G w/ Change 1, 500.6; MIL-STD-810H: 500.6; IEC 60068-2-13; ASTM D4169; ASTM D6653; RTCA/DO-160E (Section 4); RTCA/DO-160F; RTCA/DO-160G; MIL-STD-202G: Method 109; MIL-STD-810C: Method 511.1; MIL-STD-810D: Method 511.2; MIL-STD-810E: Method 511.3; MIL-STD-810F: Method 511.4; MIL-STD-810G: Method 511.5; MIL-STD-810G w/ Change 1, Method 511.6; MIL-STD-810H: Method 511.7; MIL-STD-202: Method 109B; RTCA/DO-160E (Section 9.0); RTCA/DO-160F; RTCA/DO-160G
MIL-STD-810C: Method 516.2; MIL-STD-810D: Method 516.3; MIL-STD-810E: Method 516.4; MIL-STD-810F: Method 516.5; MIL-STD-810G: Method 516.6; MIL-STD-810G w/ Change 1, 516.7; MIL-STD-810H: 516.8; MIL-STD-202G: Method 213B; MIL-STD-750E: Method 2016; MIL-STD-883-1: Method 2002; RTCA/DO-160E (Section 7); RTCA/DO-160F (Section 7); RTCA/DO-160G (Section 7); IEC 60068-2-27 (2008-02, Edition 4.0); IEC 60068-2-29; MIL-STD-810C: Method 514.2; MIL-STD-810D: Method 514.3; MIL-STD-810E: Method 514.4; MIL-STD-810F: Method 514.5; MIL-STD-810G: Method 514.6; MIL-STD-810G w/ Change 1, 514.7; MIL-STD-810H: 514.8; MIL-STD-810D: Method 520.0; MIL-STD-810E: Method 520.1; MIL-STD-810F: Method 520.2; MIL-STD-810G: Method 520.3; MIL-STD-810G w/ Change 1, 520.4; MIL-STD-810H: 520.5; MIL-STD-810G: Method 520.5; IEC 60068-2-6 (2007-12, Edition 7.0); MIL-STD-202G: Methods 201A, 204D, and 214A; MIL-STD-750E: Methods 2046 and 2056; MIL-STD-883-1: Method 2007; RTCA/DO-160E (Section 8); RTCA/DO-160F (Section 8); RTCA/DO-160G (Section 8); MIL-STD-167-1; MIL-STD 167-1; ISTA, ASTM D4169, Fixed Displacement, Sine, and Random; IEC 60068-2-6; IEC 60068-2-64
MIL-STD-202G: Method 107; MIL-STD-750E: Method 1051; MIL-STD-810C: Method 503.1; MIL-STD-810D: Method 503.2; MIL-STD-810E: Method 503.3; MIL-STD-810F: Method 503.4; MIL-STD-810G: Method 503.5; MIL-STD-810G w/ Change 1, Method 503.6; MIL-STD-810H: Method 503.7; MIL-STD-883-1: Method 1010; RTCA/DO-160E (Section 5); RTCA/DO-160F (Section 5); RTCA/DO-160G; MIL-STD-202G: Methods 103 and 106; MIL-STD-750E: Method 1021; MIL-STD-810C: Method 507.1; MIL-STD-810D: Method 507.2; MIL-STD-810E: Method 507.3; MIL-STD-810F: Method 507.4; MIL-STD-810G: Method 507.5; MIL-STD-810G w/ Change 1, Method 507.6; MIL-STD-810H: Method 507.6; MIL-STD-202: Method 103B; MIL-STD-883-1: Method 1004; IEC 60068-2-30; IEC 60068-2-78; ISTA ASTM D4169; ISTA/ASTM D4332; RTCA/DO-160E (6.0); RTCA/DO-160F; RTCA/DO-160G; ISTA; ASTM D4169; ASTM D7386; MIL-STD-810G: Method 516
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
7 lines
ISO/IEC 17025
Active2357.23
The scope document we hold says it is valid until 2027-03-31.
Accredited scope, certificate 2357.23
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | MIL-STD-810C; MIL-STD-810D; MIL-STD-810E; MIL-STD-810F; MIL-STD-810G; MIL-STD-810G w/ Change 1; MIL-STD-810H; MIL-STD-202G; MIL-STD-750E; MIL-STD-883-1; RTCA/DO-160E; RTCA/DO-160F; RTCA/DO-160G; IEC 60068-2-27; IEC 60068-2-29; IEC 60068-2-6 | Electronic and Electro-Mechanical Devices | See scope document |
| 2 | MIL-STD-883-1: Method 2007; RTCA/DO-160E (Section 8); RTCA/DO-160F (Section 8); RTCA/DO-160G (Section 8); MIL-STD-167-1; MIL-STD 167-1; ISTA, ASTM D4169, Fixed Displacement, Sine, and Random; IEC 60068-2-6; IEC 60068-2-64; MIL-STD-202G: Method 105; MIL-STD-750E: Method 1001; MIL-STD-810C: Method 500.1; MIL-STD-810D: Method 500.2; MIL-STD-810E: Method 500.3; MIL-STD-810F: Method 500.4; MIL-STD-810G: Method 500.5; MIL-STD-810G w/ Change 1, 500.6; MIL-STD-810H: 500.6; IEC 60068-2-13; ASTM D4169; ASTM D6653; RTCA/DO-160E (Section 4); RTCA/DO-160F; RTCA/DO-160G; MIL-STD-202G: Method 109; MIL-STD-810C: Method 511.1; MIL-STD-810D: Method 511.2; MIL-STD-810E: Method 511.3; MIL-STD-810F: Method 511.4; MIL-STD-810G: Method 511.5; MIL-STD-810G w/ Change 1, Method 511.6; MIL-STD-810H: Method 511.7; MIL-STD-202: Method 109B; RTCA/DO-160E (Section 9.0); RTCA/DO-160F; RTCA/DO-160G | - | 5 to 3000 Hz |
| 3 | MIL-STD-810C: Method 501.1; MIL-STD-810D: Method 501.2; MIL-STD-810E: Method 501.3; MIL-STD-810F: Method 501.4; MIL-STD-810G: Method 501.5; MIL-STD-810G w/ Change 1, Method 501.6; MIL-STD-810H: Method 501.7; MIL-STD-810C: Method 502.1; MIL-STD-810D: Method 502.2; MIL-STD-810E: Method 502.3; MIL-STD-810F: Method 502.4; MIL-STD-810G: Method 502.5; MIL-STD-810G w/ Change 1, Method 502.6; MIL-STD-810H: Method 502.7; IEC 60068-2-1; IEC 60068-2-2; IEC 60068-2-14; RTCA/DO-160E; RTCA/DO-160F; RTCA/DO-160G; MIL-STD-202G: Method 107; MIL-STD-750E: Method 1051; MIL-STD-810C: Method 503.1; MIL-STD-810D: Method 503.2; MIL-STD-810E: Method 503.3; MIL-STD-810F: Method 503.4; MIL-STD-810G: Method 503.5; MIL-STD-810G w/ Change 1, Method 503.6; MIL-STD-810H: Method 503.7; MIL-STD-883-1: Method 1010; RTCA/DO-160E (Section 5); RTCA/DO-160F (Section 5); RTCA/DO-160G; MIL-STD-202G: Methods 103 and 106; MIL-STD-750E: Method 1021; MIL-STD-810C: Method 507.1; MIL-STD-810D: Method 507.2; MIL-STD-810E: Method 507.3; MIL-STD-810F: Method 507.4; MIL-STD-810G: Method 507.5; MIL-STD-810G w/ Change 1, Method 507.6; MIL-STD-810H: Method 507.6; MIL-STD-202: Method 103B; MIL-STD-883-1: Method 1004; IEC 60068-2-30; IEC 60068-2-78; ISTA ASTM D4169; ISTA/ASTM D4332; RTCA/DO-160E (6.0); RTCA/DO-160F; RTCA/DO-160G; ISTA; ASTM D4169; ASTM D7386; MIL-STD-810G: Method 516 | - | -75 to 190 ºC |
| 4 | MIL-STD-810C: Method 516.2; MIL-STD-810D: Method 516.3; MIL-STD-810E: Method 516.4; MIL-STD-810F: Method 516.5; MIL-STD-810G: Method 516.6; MIL-STD-810G w/ Change 1, 516.7; MIL-STD-810H: 516.8; MIL-STD-202G: Method 213B; MIL-STD-750E: Method 2016; MIL-STD-883-1: Method 2002; RTCA/DO-160E (Section 7); RTCA/DO-160F (Section 7); RTCA/DO-160G (Section 7); IEC 60068-2-27 (2008-02, Edition 4.0); IEC 60068-2-29; MIL-STD-810C: Method 514.2; MIL-STD-810D: Method 514.3; MIL-STD-810E: Method 514.4; MIL-STD-810F: Method 514.5; MIL-STD-810G: Method 514.6; MIL-STD-810G w/ Change 1, 514.7; MIL-STD-810H: 514.8; MIL-STD-810D: Method 520.0; MIL-STD-810E: Method 520.1; MIL-STD-810F: Method 520.2; MIL-STD-810G: Method 520.3; MIL-STD-810G w/ Change 1, 520.4; MIL-STD-810H: 520.5; MIL-STD-810G: Method 520.5; IEC 60068-2-6 (2007-12, Edition 7.0); MIL-STD-202G: Methods 201A, 204D, and 214A; MIL-STD-750E: Methods 2046 and 2056; MIL-STD-883-1: Method 2007; RTCA/DO-160E (Section 8); RTCA/DO-160F (Section 8); RTCA/DO-160G (Section 8); MIL-STD-167-1; MIL-STD 167-1; ISTA, ASTM D4169, Fixed Displacement, Sine, and Random; IEC 60068-2-6; IEC 60068-2-64 | - | 5 to 3000 Hz |
| 5 | MIL-STD-883-1: Method 200; MIL-STD-202G: Method 212 TC, B, and C; MIL-STD-750E: Method 2006; MIL-STD-810C: Method 513.2; MIL-STD-810D: Method 513.3; MIL-STD-810E: Method 513.4; MIL-STD-810F: Method 513.5; MIL-STD-810G: Method 513.6; MIL-STD-810G w/ Change 1, 513.7; MIL-STD-810H: 513.8; MIL-STD-202G: Method 212A; RTCA/DO-160E; RTCA/DO-160F; RTCA/DO-160G; MIL-STD-202G: Method 105; MIL-STD-750E: Method 1001; MIL-STD-810C, Method 500.1; MIL-STD-810D, Method 500.2; MIL-STD-810E, Method 500.3; MIL-STD-810F, Method 500.4; MIL-STD-810G, Method 500.5; MIL-STD-810G w/ Change 1, 500.6; MIL-STD-810H, 500.6; IEC 60068-2-13; ASTM D4169; ASTM D6653; RTCA/DO-160E Section 4; RTCA/DO-160F; RTCA/DO-160G; MIL-STD-810C: Method 501.1; MIL-STD-810D: Method 501.2; MIL-STD-810E: Method 501.3; MIL-STD-810F: Method 501.4; MIL-STD-810G: Method 501.5; MIL-STD-810G w/ Change 1, Method 501.6; MIL-STD-810H: Method 501.7; MIL-STD-810C: Method 502.1; MIL-STD-810D: Method 502.2; MIL-STD-810E: Method 502.3; MIL-STD-810F: Method 502.4; MIL-STD-810G: Method 502.5; MIL-STD-810G w/ Change 1, Method 502.6; MIL-STD-810H: Method 502.7; IEC 60068-2-1; IEC 60068-2-2; IEC 60068-2-14 | - | 1 to 120 g |
| 6 | MIL-STD-202G: Method 107; MIL-STD-750E: Method 1051; MIL-STD-810C: Method 503.1; MIL-STD-810D: Method 503.2; MIL-STD-810E: Method 503.3; MIL-STD-810F: Method 503.4; MIL-STD-810G: Method 503.5; MIL-STD-810G w/ Change 1, Method 503.6; MIL-STD-810H: Method 503.7; MIL-STD-883-1: Method 1010; RTCA/DO-160E (Section 5); RTCA/DO-160F (Section 5); RTCA/DO-160G; MIL-STD-202G: Methods 103 and 106; MIL-STD-750E: Method 1021; MIL-STD-810C: Method 507.1; MIL-STD-810D: Method 507.2; MIL-STD-810E: Method 507.3; MIL-STD-810F: Method 507.4; MIL-STD-810G: Method 507.5; MIL-STD-810G w/ Change 1, Method 507.6; MIL-STD-810H: Method 507.6; MIL-STD-202: Method 103B; MIL-STD-883-1: Method 1004; IEC 60068-2-30; IEC 60068-2-78; ISTA ASTM D4169; ISTA/ASTM D4332; RTCA/DO-160E (6.0); RTCA/DO-160F; RTCA/DO-160G; ISTA; ASTM D4169; ASTM D7386; MIL-STD-810G: Method 516 | - | -75 to 200 ºC |
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
TEKTRONIX, INC.
N. Billerica, MA
for technical competence in the field of
Mechanical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 3rd day of February 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 2357.23
Valid to March 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- WESTPAKSan Diego, CA · ~4,131 kmA2LAShares 2 accredited test methodsASTM D4169IEC 60068-2-27
- Element U.S. Space & DefenseFullerton, CA · ~4,133 kmA2LAShares 2 accredited test methodsIEC 60068-2-1IEC 60068-2-27
- Element Materials Technology BoxboroughBoxborough, MA · ~22 kmA2LAShares 1 accredited test methodIEC 60068-2-1
- Green Mountain ElectromagneticsMiddlebury, VT · ~220 kmA2LAShares 1 accredited test methodIEC 60068-2-1
- DDL, Inc.Edison, NJ · ~347 kmA2LAShares 1 accredited test methodASTM D4169
Accreditation data refreshed from the A2LA register on .