United States
Tektronix, Inc. - N. Billerica Test
7 Sterling Road, 01862, North Billerica, MA, United States
A2LA|2357.23ISO/IEC 17025Register collected 2026-08-22
Certificates
1
Scope items
7
Locations
1
Contact this laboratory
Work at Tektronix, Inc. - N. Billerica Test?
Claim this profile to keep it accurate.
Claim this profileRegister record
- A2LACollected
- 2357.23Active
Certificates and scope
1A2LA
ISO/IEC 17025
Active2357.23
Accredited scope, certificate 2357.23
| Discipline | Method | Matrix | Range |
|---|---|---|---|
| mechanical | MIL-STD-810C: Method 516.2; MIL-STD-810D: Method 516.3; MIL-STD-810E: Method 516.4; MIL-STD-810F: Method 516.5; MIL-STD-810G: Method 516.6; MIL-STD-810G w/ Change 1, 516.7; MIL-STD-810H: 516.8; MIL-STD-202G: Method 213B; MIL-STD-750E: Method 2016; MIL-STD-883-1: Method 2002; RTCA/DO-160E (Section 7); RTCA/DO-160F (Section 7); RTCA/DO-160G (Section 7); IEC 60068-2-27 (2008-02, Edition 4.0); IEC 60068-2-29; MIL-STD-810C: Method 514.2; MIL-STD-810D: Method 514.3; MIL-STD-810E: Method 514.4; MIL-STD-810F: Method 514.5; MIL-STD-810G: Method 514.6; MIL-STD-810G w/ Change 1, 514.7; MIL-STD-810H: 514.8; MIL-STD-810D: Method 520.0; MIL-STD-810E: Method 520.1; MIL-STD-810F: Method 520.2; MIL-STD-810G: Method 520.3; MIL-STD-810G w/ Change 1, 520.4; MIL-STD-810H: 520.5; MIL-STD-810G: Method 520.5; IEC 60068-2-6 (2007-12, Edition 7.0); MIL-STD-202G: Methods 201A, 204D, and 214A; MIL-STD-750E: Methods 2046 and 2056; MIL-STD-883-1: Method 2007; RTCA/DO-160E (Section 8); RTCA/DO-160F (Section 8); RTCA/DO-160G (Section 8); MIL-STD-167-1; MIL-STD 167-1; ISTA, ASTM D4169, Fixed Displacement, Sine, and Random; IEC 60068-2-6; IEC 60068-2-64 | - | 5 to 3000 Hz |
| mechanical | MIL-STD-202G: Method 107; MIL-STD-750E: Method 1051; MIL-STD-810C: Method 503.1; MIL-STD-810D: Method 503.2; MIL-STD-810E: Method 503.3; MIL-STD-810F: Method 503.4; MIL-STD-810G: Method 503.5; MIL-STD-810G w/ Change 1, Method 503.6; MIL-STD-810H: Method 503.7; MIL-STD-883-1: Method 1010; RTCA/DO-160E (Section 5); RTCA/DO-160F (Section 5); RTCA/DO-160G; MIL-STD-202G: Methods 103 and 106; MIL-STD-750E: Method 1021; MIL-STD-810C: Method 507.1; MIL-STD-810D: Method 507.2; MIL-STD-810E: Method 507.3; MIL-STD-810F: Method 507.4; MIL-STD-810G: Method 507.5; MIL-STD-810G w/ Change 1, Method 507.6; MIL-STD-810H: Method 507.6; MIL-STD-202: Method 103B; MIL-STD-883-1: Method 1004; IEC 60068-2-30; IEC 60068-2-78; ISTA ASTM D4169; ISTA/ASTM D4332; RTCA/DO-160E (6.0); RTCA/DO-160F; RTCA/DO-160G; ISTA; ASTM D4169; ASTM D7386; MIL-STD-810G: Method 516 | - | -75 to 200 ºC |
| mechanical | - | - | - |
| mechanical | MIL-STD-883-1: Method 200; MIL-STD-202G: Method 212 TC, B, and C; MIL-STD-750E: Method 2006; MIL-STD-810C: Method 513.2; MIL-STD-810D: Method 513.3; MIL-STD-810E: Method 513.4; MIL-STD-810F: Method 513.5; MIL-STD-810G: Method 513.6; MIL-STD-810G w/ Change 1, 513.7; MIL-STD-810H: 513.8; MIL-STD-202G: Method 212A; RTCA/DO-160E; RTCA/DO-160F; RTCA/DO-160G; MIL-STD-202G: Method 105; MIL-STD-750E: Method 1001; MIL-STD-810C, Method 500.1; MIL-STD-810D, Method 500.2; MIL-STD-810E, Method 500.3; MIL-STD-810F, Method 500.4; MIL-STD-810G, Method 500.5; MIL-STD-810G w/ Change 1, 500.6; MIL-STD-810H, 500.6; IEC 60068-2-13; ASTM D4169; ASTM D6653; RTCA/DO-160E Section 4; RTCA/DO-160F; RTCA/DO-160G; MIL-STD-810C: Method 501.1; MIL-STD-810D: Method 501.2; MIL-STD-810E: Method 501.3; MIL-STD-810F: Method 501.4; MIL-STD-810G: Method 501.5; MIL-STD-810G w/ Change 1, Method 501.6; MIL-STD-810H: Method 501.7; MIL-STD-810C: Method 502.1; MIL-STD-810D: Method 502.2; MIL-STD-810E: Method 502.3; MIL-STD-810F: Method 502.4; MIL-STD-810G: Method 502.5; MIL-STD-810G w/ Change 1, Method 502.6; MIL-STD-810H: Method 502.7; IEC 60068-2-1; IEC 60068-2-2; IEC 60068-2-14 | - | 1 to 120 g |
| mechanical | MIL-STD-810C; MIL-STD-810D; MIL-STD-810E; MIL-STD-810F; MIL-STD-810G; MIL-STD-810G w/ Change 1; MIL-STD-810H; MIL-STD-202G; MIL-STD-750E; MIL-STD-883-1; RTCA/DO-160E; RTCA/DO-160F; RTCA/DO-160G; IEC 60068-2-27; IEC 60068-2-29; IEC 60068-2-6 | Electronic and Electro-Mechanical Devices | 5 to 30000 Hz; g; lbf |
| mechanical | MIL-STD-883-1: Method 2007; RTCA/DO-160E (Section 8); RTCA/DO-160F (Section 8); RTCA/DO-160G (Section 8); MIL-STD-167-1; MIL-STD 167-1; ISTA, ASTM D4169, Fixed Displacement, Sine, and Random; IEC 60068-2-6; IEC 60068-2-64; MIL-STD-202G: Method 105; MIL-STD-750E: Method 1001; MIL-STD-810C: Method 500.1; MIL-STD-810D: Method 500.2; MIL-STD-810E: Method 500.3; MIL-STD-810F: Method 500.4; MIL-STD-810G: Method 500.5; MIL-STD-810G w/ Change 1, 500.6; MIL-STD-810H: 500.6; IEC 60068-2-13; ASTM D4169; ASTM D6653; RTCA/DO-160E (Section 4); RTCA/DO-160F; RTCA/DO-160G; MIL-STD-202G: Method 109; MIL-STD-810C: Method 511.1; MIL-STD-810D: Method 511.2; MIL-STD-810E: Method 511.3; MIL-STD-810F: Method 511.4; MIL-STD-810G: Method 511.5; MIL-STD-810G w/ Change 1, Method 511.6; MIL-STD-810H: Method 511.7; MIL-STD-202: Method 109B; RTCA/DO-160E (Section 9.0); RTCA/DO-160F; RTCA/DO-160G | - | 5 to 3000 Hz |
| mechanical | MIL-STD-810C: Method 501.1; MIL-STD-810D: Method 501.2; MIL-STD-810E: Method 501.3; MIL-STD-810F: Method 501.4; MIL-STD-810G: Method 501.5; MIL-STD-810G w/ Change 1, Method 501.6; MIL-STD-810H: Method 501.7; MIL-STD-810C: Method 502.1; MIL-STD-810D: Method 502.2; MIL-STD-810E: Method 502.3; MIL-STD-810F: Method 502.4; MIL-STD-810G: Method 502.5; MIL-STD-810G w/ Change 1, Method 502.6; MIL-STD-810H: Method 502.7; IEC 60068-2-1; IEC 60068-2-2; IEC 60068-2-14; RTCA/DO-160E; RTCA/DO-160F; RTCA/DO-160G; MIL-STD-202G: Method 107; MIL-STD-750E: Method 1051; MIL-STD-810C: Method 503.1; MIL-STD-810D: Method 503.2; MIL-STD-810E: Method 503.3; MIL-STD-810F: Method 503.4; MIL-STD-810G: Method 503.5; MIL-STD-810G w/ Change 1, Method 503.6; MIL-STD-810H: Method 503.7; MIL-STD-883-1: Method 1010; RTCA/DO-160E (Section 5); RTCA/DO-160F (Section 5); RTCA/DO-160G; MIL-STD-202G: Methods 103 and 106; MIL-STD-750E: Method 1021; MIL-STD-810C: Method 507.1; MIL-STD-810D: Method 507.2; MIL-STD-810E: Method 507.3; MIL-STD-810F: Method 507.4; MIL-STD-810G: Method 507.5; MIL-STD-810G w/ Change 1, Method 507.6; MIL-STD-810H: Method 507.6; MIL-STD-202: Method 103B; MIL-STD-883-1: Method 1004; IEC 60068-2-30; IEC 60068-2-78; ISTA ASTM D4169; ISTA/ASTM D4332; RTCA/DO-160E (6.0); RTCA/DO-160F; RTCA/DO-160G; ISTA; ASTM D4169; ASTM D7386; MIL-STD-810G: Method 516 | - | -75 to 190 ºC |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.
Location
Labs with overlapping accredited scope in United States
- WESTPAKSan Diego, CA · ~4,131 kmA2LAShares 2 accredited test methodsASTM D4169IEC 60068-2-27
- Green Mountain ElectromagneticsMiddlebury, VT · ~220 kmA2LAShares 1 accredited test methodIEC 60068-2-1
- DDL, Inc.Edison, NJ · ~347 kmA2LAShares 1 accredited test methodASTM D4169
- Delserro Engineering SolutionsEaston, PA · ~388 kmA2LAShares 1 accredited test methodIEC 60068-2-6
- Oneida Research ServicesReading, PA · ~460 kmA2LAShares 1 accredited test methodASTM D4169
Accreditation data collected from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.