CalSource
235 Middle road Suite 100, 14467, Henrietta, NY, United States
Visit website- Scope lines
- 22
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 22 scope lines.
A2LA certificate 2133.02 · 22 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO 17025:2017 | - | to 72 in |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 2 of 21
Parameter/Equipment
Range
CMC2 (±)
Comments
Cylindrical Outside
Diameter
Up to 4 in
11 μin
Mahr 828
bench micrometer
Cylindrical Inside
Diameter
Up to 1 in
(1 to 4) in
(4 to 6) in
(6 to 10) in
21 μin
35 μin
51 μin
82 μin
Zeiss universal
measuring machine,
master ring gages
Thread Plugs – Pitch
Diameter
(6 to 120) TPI
Up to 1 in
(1 to 10) in
57 μin
83 μin
Bench micrometer,
gage blocks,
thread wires
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC
2, 6 (±)
Comments
DC Voltage3
– Measure
Up to 100 mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
100 V to 1 kV
(1 to 10) kV
(20 to 35) kV
12 μV/V + 0.3 μV
5.8 μV/V + 0.3 μV
4.2 μV/V + 0.5 μV
9.6 μV/V + 30 μV
11 μV/V + 0.1 mV
0.043 % + 0.03 V
0.04 % + 0.7 V
HP 3458A Opt 002
8.5 digit multimeter
Vitrek 4700
high voltage meter
DC Voltage3 – Generate
Up to 220 mV
220 mV to 2.2 V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
220 V to 1.1 kV
11 μV/V + 0.4 μV
6.4 μV/V + 0.7 μV
5.4 μV/V + 2.5 μV
5.3 μV/V + 4 μV
8.6 μV/V + 50 μV
10 μV/V + 0.5 mV
Fluke 5720A
multiproduct calibrator | to 4 in |
| 3 | - | OilShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 3 of 21
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
DC Current3 – Measure
Up to 100 nA
100 nA to 1 μA
(1 to 10) μA
(10 to 100) μA
100 μA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
30 μA/A + 40 pA
30 μA/A + 40 pA
26 μA/A + 0.1 nA
25 μA/A + 0.8 nA
24 μA/A + 5 nA
24 μA/A + 50 nA
42 μA/A + 0.5 μA
0.14 mA/A + 10 μA
HP 3458A Opt 002
8.5 digit multimeter
DC Current – Generate
3
Up to 220 μA
220 μA to 2.2 mA
(2.2 to 22) mA
(22 to 220) mA
220 mA to 2.2 A
(2.2 to 11) A
(11 to 20.5) A
41 μA/A + 6 nA
39 μA/A + 7 nA
39 μA/A + 40 nA
46 μA/A + 0.7 μA
130 μA/A + 12 μA
0.57 mA/A + 0.48 mA
1.1 mA/A + 0.75 mA
Fluke 5720A
multiproduct calibrator,
Fluke 5725A amplifier
Fluke 5520A
multiproduct calibrator
Multiproduct Calibrator
DC Current Clamp –
Generate
3 (Non-
Toroidal)
(20 to 150) A
(150 to 1000) A
0.96 % + 0.14 A
2.5 % + 0.5 A
Fluke 5520A
multiproduct calibrator,
Fluke 5500A/COIL
50-turn coil
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Voltage – Measure 3
(1 to 10) mV
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
0.35 mV/V + 3 μV
0.25 mV/V + 1.1 μV
0.37 mV/V + 1.1 μV
1.2 mV/V + 1.1 μV
5.8 mV/V + 1.1 μV
47 mV/V + 2 μV
14 mV/V + 5 μV
HP 3458A Opt 002
8.5 digit multimeter | to 1000 A |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 4 of 21
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Voltage – Measure 3
(cont)
(10 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(2 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
1 to 40) Hz
40 Hz to 1kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(2 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
(1 to 40) Hz
40 Hz to 1kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(2 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
93 μV/V + 4 μV
88 μV/V + 2 μV
0.17 mV/V + 2 μV
0.36 mV/V + 2 μV
0.93 mV/V + 2 μV
3.5 mV/V + 10 μV
12 mV/V + 10 μV
18 mV/V + 10 μV
47 mV/V + 70 μV
47 mV/V + 80 μV
0.18 V/V + 0.1 mV
93 μV/V + 40 μV
86 μV/V + 20 μV
0.17 mV/V + 20 μV
0.36 mV/V + 20 μV
0.93 mV/V + 20 μV
3.5 mV/V + 0.1 mV
12 mV/V + 0.1 mV
18 mV/V + 0.1 mV
47 mV/V + 0.7 mV
47 mV/V + 0.8 mV
0.18 V/V + 1 mV
93 μV/V + 0.4 mV
86 μV/V + 0.2 mV
0.17 mV/V + 0.2 mV
0.36 mV/V + 0.2 mV
0.93 mV/V + 0.2 mV
3.5 mV/V + 1 mV
12 mV/V + 1 mV
18 mV/V + 1 mV
47 mV/V + 7 mV
47 mV/V + 8 mV
0.18 V/V + 10 mV
0.24 mV/V + 4 mV
0.24 mV/V + 2 mV
0.24 mV/V + 2 mV
0.41 mV/V + 2 mV
1.4 mV/V + 2 mV
4.7 mV/V + 10 mV
18 mV/V + 10 mV
HP 3458A Opt 002
8.5 digit multimeter | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 5 of 21
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Voltage – Measure 3
(cont)
(100 to 700) V
(1.1 to 10) kV
(10 to 35) kV
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
50 Hz
50 Hz
0.49 mV/V + 28 mV
0.48 mV/V + 14 mV
0.71 mV/V + 14 mV
1.4 mV/V + 14 mV
3.5 mV/V + 14 mV
0.15 % + 0.1V
0.12 % + 0.2 V
HP 3458A Opt 002
8.5 digit multimeter
Vitrek 4700 high voltag
e
meter
AC Voltage – Generate
3
Up to 2.2 mV
(2.2 to 22) mV
(22 to 220) mV
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
0.067 % + 4 μV
0.082 % + 4 μV
0.067 % + 4 μV
0.12 % + 4 μV
0.19 % + 5 μV
0.35 % + 10 μV
0.5 % + 20 μV
0.68 % + 20 μV
0.041 % + 4 μV
0.017 % + 4 μV
0.016 % + 4 μV
0.033 % + 4 μV
0.071 % + 5 μV
0.15 % + 10 μV
0.2 % + 20 μV
0.36 % + 20 μV
0.03 % + 12 μV
0.012 % + 7 μV
0.011 % + 7 μV
0.025 % + 7 μV
0.057 % + 17 μV
0.11 % + 20 μV
0.17 % + 25 μV
0.33 % + 45 μV
Fluke 5720A
multiproduct calibrator | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 6 of 21
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Voltage – Generate3
(cont)
220 mV to 2.2 V
(2.2 to 22) V
(22 to 220) V
220 V to 1.1 kV
750 V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(15 to 50) Hz
50 Hz to 1 kHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 30) kHz
(30 to 50) kHz
(50 to 100) kHz
0.28 mV/V + 40 μV
0.11 mV/V + 15 μV
53 μV/V + 8 μV
0.10 mV/V + 10 μV
0.15 mV/V + 30 μV
0.52 mV/V + 80 μV
1.2 mV/V + 0.2 mV
2.2 mV/V + 0.3 mV
0.28 mV/V + 0.40 mV
0.11 mV/V + 0.15 mV
53 μV/V + 50 μV
88 µV/V + 0.1 mV
0.12 mV/V + 0.2 mV
0.33 mV/V + 0.6 mV
1.2 mV/V + 2 mV
1.8 mV/V + 3.2 mV
0.28 mV/V + 4 mV
0.11 mV/V + 1.5 mV
61 μV/V + 0.6 mV
94 µV/V + 1 mV
0.18 mV/V + 2.5 mV
1.1 mV/V + 16 mV
5.1 mV/V + 40 mV
8.7 mV/V + 80 mV
0.35 mV/V + 16 mV
82 μV/V + 3.5 mV
0.11 mV/V + 4 mV
0.2 mV/V + 6 mV
0.7 mV/V + 11 mV
0.7 mV/V + 11 mV
2.7 mV/V + 45 mV
Fluke 5720A
multiproduct calibrator
Fluke 5720A
Fluke 5720A w/5725A
amplifier | ||
| 7 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 7 of 21
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Current –Measure3
Up to 100 μA
(1 to 100) mA
100 mA to 1 A
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 1 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
4.6 mA/A + 30 nA
1.8 mA/A + 30 nA
0.7 mA/A + 30 nA
0.7 mA/A + 30 nA
4.6 mA/A + 20 μA
1.8 mA/A + 20 μA
0.7 mA/A + 20 μA
0.36 mA/A + 20 μA
4.6 mA/A + 0.2 mA
1.9 mA/A + 0.2 mA
0.93 mA/A + 0.2 mA
1.2 mA/A + 0.2 mA
HP 3458A Opt 002
8.5 digit multimeter
AC Current – Generate3
Up to 220 μA
220 μA to 2.2 mA
(2.2 to 22) mA
(22 to 220) mA
220 mA to 2.2 A
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
20 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.046 % + 16 nA
0.042 % + 10 nA
0.041 % + 8 nA
0.049 % + 12 nA
0.12 % + 65 nA
0.051 % + 40 nA
0.045 % + 35 nA
0.043 % + 35 nA
0.046 % + 0.11 μA
0.14 % + 0.65 μA
0.051 % + 0.4 μA
0.045 % + 0.35 μA
0.043 % + 0.35 μA
0.047 % + 0.55 μA
0.14 % + 5 μA
0.047 % + 4 μA
0.043 % + 3.5 μA
0.042 % + 2.5 μA
0.045 % + 3.5 μA
0.12 % + 10 μA
0.08 % + 35 μA
0.09 % + 80 μA
0.82 % + 0.16 mA
Fluke 5720A
multiproduct calibrator | to 1 A |
| 8 | - | OilShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 8 of 21
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Current – Generate3
(cont)
(2.2 to 11) A
(11 to 20.5) A
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
0.12 % + 0.17 mA
0.16 % + 0.38 mA
0.43 % + 0.75 mA
0.3 % + 5 mA
0.26 % + 5 mA
0.6 % + 5 mA
Fluke 5720A
multiproduct
calibrator, Fluke
5725A amplifier
Fluke 5520A
multiproduct calibrator
AC Current Clamp –
Generate
3 (Non-
Toroidal)
(20 to 150) A
(150 to 1000) A
(45 to 65) Hz
(65 to 400) Hz
(45 to 65) Hz
(65z to 400) Hz
0.97 % + 0.25 A
1.4 % + 0.25A
1.3 % + 0.9 A
1.8 % + 0.9 A
Fluke 5520A
multiproduct
calibrator,
Fluke 5500A/COIL
50-turn coil
AC Current Clamp –
Generate
3 (Toroidal)
(20 to 150) A
(150 to 1000) A
(45 to 65) Hz
(65 to 400) Hz
(45 to 65) Hz
(65 to 400) Hz
0.56 % + 0.025 A
1.1 % + 0.027A
1.2 % + 0.09 A
1.7 % + 0.1 A | See scope document |
| 9 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 9 of 21
Parameter/Equipment
Range
CMC2, 5, 6 (±)
Comments
Resistance – Generate3
0 Ω
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
42 μΩ
0.1 mΩ/Ω
0.12 mΩ/Ω
24 μΩ/Ω
26 μΩ/Ω
14 μΩ/Ω
14 μΩ/Ω
13 μΩ/Ω
13 μΩ/Ω
13 μΩ/Ω
13 μΩ/Ω
15 μΩ/Ω
15 μΩ/Ω
18 μΩ/Ω
45 μΩ/Ω
45 μΩ/Ω
51 μΩ/Ω
0.13 mΩ/Ω
Fluke 5720A
multiproduct calibrator
Resistance3 – Generate
Up to 11 Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
330 Ω to 1.1 kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
330 kΩ to 1.1 MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
330 MΩ to 1.1 GΩ
28 µΩ/Ω + 0.001 Ω
21 µΩ/Ω + 0.0015 Ω
21 µΩ/Ω + 0.0014 Ω
21 µΩ/Ω + 0.002 Ω
21 µΩ/Ω + 0.002 Ω
21 µΩ/Ω + 0.02 Ω
21 µΩ/Ω + 0.02 Ω
22 µΩ/Ω + 0.2 Ω
21 µΩ/Ω + 0.2 Ω
24 µΩ/Ω + 2 Ω
24 µΩ/Ω + 2 Ω
60 µΩ/Ω + 30 Ω
90 µΩ/Ω + 50 Ω
0.017 % + 2.5 kΩ
0.036 %
0.45 %
1.1 %
Fluke 5520A
Resistance – Generate
3
(Fixed Artifacts)
10 mΩ
100 mΩ
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
100 kΩ
1 MΩ
12 μΩ/Ω + 0.1 nΩ
12 μΩ/Ω
12 μΩ/Ω
12 μΩ/Ω
12 μΩ/Ω
12 μΩ/Ω
12 μΩ/Ω
23 μΩ/Ω
0.12 mΩ/Ω
L&N 4222 resistor
L&N 4015-B resistor
L&N 4020-B resistor
L&N 8070/10 resistor
L&N 100 resistor
Gray 1000 resistor
Gray 10000 resistor
L&N 4045-B resistor
ESI SR-1 resistor | to 1100000000 Ω |
| 10 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 10 of 21
Parameter/Equipment
Range
CMC2, 5, 6 (±)
Comments
Resistance – Measure3
Up to 10 Ω
(10 to 100) Ω
100 Ω to 1 kΩ
(1 to 10) kΩ
(10 to 100) kΩ
100 kΩ to 1 MΩ
(1 to 10) MΩ
(10 to 100) MΩ
100 MΩ to 1 GΩ
23 μΩ/Ω + 0.1 mΩ
23 μΩ/Ω + 1 mΩ
18 μΩ/Ω + 1 mΩ
18 μΩ/Ω + 10 mΩ
18 μΩ/Ω + 0.1 Ω
23 μΩ/Ω + 4 Ω
87 μΩ/Ω + 0.1 kΩ
1.2 mΩ/Ω + 1 kΩ
12 mΩ/Ω + 10 kΩ
HP 3458A Opt 002
8.5 digit multimeter
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
Capacitance – Measure
100 pF to 100 µF
(100 to 500) µF
(100 to 1000) µF
(1000 to 3300) µF
100 pF to 100 nF
100 nF to 100 µF
(100 to 1000) µF
1 kHz Only
1 kHz Only
1 kHz Only
1 kHz Only
500 Hz to 10 kHz
12 Hz to 10 kHz
50 Hz to 2 kHz
0.07 %
0.25 %
0.48 %
1.5 %
0.20 %
0.20 %
1.9 %
Genrad 1689
Parameter/Equipment
Range
CMC2, 5, 6 (±)
Comments
Capacitance – Generate3
(Simulation)
(0.19 to 3.3) nF
(3.3 to 11) nF
(11 to 110) nF
(110 to 330) nF
(0.33 to 1.1) μF
(1.1 to 3.3) μF
(3.3 to 11) μF
(11 to 33) μF
(33 to 110) μF
(110 to 330) μF
(0.33 to 1.1) mF
(1.1 to 3.3) mF
(3.3 to 11) mF
(11 to 33) mF
(33 to 110) mF
0.37 % + 0.01 nF
0.28 % + 0.01 nF
0.23 % + 0.1 nF
0.23 % + 0.3 nF
0.23 % + 1 nF
0.23 % + 3 nF
0.24 % + 10 nF
0.32 % + 30 nF
0.34 % + 100 nF
0.35 % + 300 nF
0.35 % + 1 μF
0.32 % + 3 μF
0.32 % + 10 μF
0.52 % + 30 μF
0.81 % + 100 μF
Fluke 5520A
multiproduct calibrator | to 10 Ω |
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 11 of 21
Parameter/Range
Frequency
CMC2, 6
(±)
Comments
Capacitance – Generate3
(Fixed Artifacts)
100 pF
1 nF
1 kHz
0.0024 pF
0.024 pF
Standard capacitors
General Radio 1404-B
General Radio 1404-A
Inductance – Measure
100 μH to 10 H
100 Hz & 1 kHz
0.3 mH/H
General Radio 1689M
RLC bridge
Inductance – Generate
3
(Fixed Artifacts)
100 μH
1 mH
10 mH
100 mH
1 H
100 Hz & 1 kHz
0.31 μH
1.2 μH
16 μH
0.12 mH
1.3 mH
Standard inductors
General Radio 1482B
General Radio 1482E
General Radio 1482H
General Radio 1482L
General Radio 1482P
Phase
3 – Generate
(Dual ACV Outputs)
3.3V, PF 0 to 1 (0 to 90)°
3.3V, PF 1 (0 to 90)°
(10 to 65) Hz
(65 to 500) Hz
500 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.07°
0.17°
0.34°
1.7°
3.4°
6.7°
Fluke 5520A | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 12 of 21
Parameter/Equipment
Range
CMC2, 4
(±)
Comments
Oscilloscopes3, 7
Leveled Sine Wave
50 kHz Reference
50 kHz Reference
10 Hz to 100 kHz:
Into 1 MΩ Load
Into 50 Ω Load
Rise Time Source
250 ps Nominal
Time Marker
Into 50 Ω Load
5 mV to 5 V p-p
5 mV to 5.5 V p-p
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(0 to 33) V p-p
(0 to 6.5) V p-p
4 mVp-p to 2.5 Vp-p
1 kHz to 10 MHz
2 ns to 20 ms
50 ms to 5 s
23 mV/V + 300 μV
20 mV/V + 0.1 mV
25 mV/V + 0.1 mV
47 mV/V + 0.1 mV
35 mV/V + 0.1 mV
35 mV/V + 0.1 mV
50 ps
2.5 μs/s
(25 + 1000t) μs
Fluke 5520A/6
multiproduct calibrator
with 600 MHz scope
option
Electrical Simulation of
Thermocouples &
Thermocouple
Indicators
3 –
Type B
Type C
Type E
(600 to 800) °C
(800 to 1000) °C
(1000 to 1550) °C
(1550 to 1820) °C
(0 to 150) °C
(150 to 650) °C
(650 to 1000) °C
(1000 to 1800) °C
(1800 to 2316) °C
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
0.34 °C
0.27 °C
0.24 °C
0.26 °C
0.24 °C
0.21 °C
0.25 °C
0.39 °C
0.65 °C
0.39 °C
0.13 °C
0.12 °C
0.13 °C
0.17 °C
Fluke 5520A | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 13 of 21
Parameter/Equipment
Range
CMC2
(±)
Comments
Electrical Simulation of
Thermocouples &
Thermocouple
Indicators
3 – (cont)
Type J
Type K
Type L
Type N
Type R
Type S
Type T
Type U
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 °C to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to 800) °C
(800 to 900) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
(-200 to 0) °C
(0 to 400) °C
0.22 °C
0.13 °C
0.12 °C
0.14 °C
0.19 °C
0.26 °C
0.15 °C
0.13 °C
0.21 °C
0.32 °C
0.29 °C
0.21 °C
0.14 °C
0.32 °C
0.18 °C
0.15 °C
0.15 °C
0.22 °C
0.45 °C
0.28 °C
0.26 °C
0.32 °C
0.37 °C
0.28 °C
0.30 °C
0.37 °C
0.50 °C
0.20 °C
0.14 °C
0.12 °C
0.44 °C
0.22 °C
Fluke 5520A | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 14 of 21
Parameter/Equipment
Range
CMC2
(±)
Comments
Electrical Simulation of
RTD Indicating Devices –
Generate
3
Pt 385, 100 Ω
Pt 3926, 100 Ω
Pt 3916, 100 Ω
Pt 385, 200 Ω
Pt 385, 500 Ω
Pt 385, 1000 Ω
PtNi 385, 120 Ω
(-200 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(-200 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 100) °C
(100 to 260) °C
(260 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 600) °C
(600 to 630) °C
(-80 to100) °C
(100 to 260) °C
0.06 °C
0.09 °C
0.11 °C
0.12 °C
0.14 °C
0.27 °C
0.06 °C
0.09 °C
0.11 °C
0.12 °C
0.14 °C
0.29 °C
0.05 °C
0.06 °C
0.07 °C
0.08 °C
0.1 °C
0.11 °C
0.12 °C
0.27 °C
0.05 °C
0.06 °C
0.14 °C
0.15 °C
0.17 °C
0.19 °C
0.05 °C
0.06 °C
0.07 °C
0.1 °C
0.11 °C
0.13 °C
0.04 °C
0.05 °C
0.06 °C
0.07 °C
0.08 °C
0.27 °C
0.09 °C
0.17 °C
Fluke 5520A
multiproduct calibrator | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 15 of 21
Parameter/Equipment
Range
CMC2
(±)
Comments
Electrical Simulation of
RTD Indicating Devices –
Generate
3 (cont)
Cu 427, 10 Ω
(-100 to 260) °C
0.35 °C
Fluke 5520A
multiproduct calibrator
III. Electrical – RF/Microwave
Parameter/Equipment
Range
CMC2, 9
(±)
Comments
RF Power Reference
1 mW, 50 MHz
0.03 mW
HP 8478 w/
432B & 3458A
RF Power Sensor
Calibration Factors
100 kHz to 4.6 GHz
(4.6 to 18) GHz
1.0 %
1.7 %
Tegam F1130A,
Tegam 1830A
S-Parameter – S11/S22
Magnitude (linear)
100 kHz to 10 MHz
10 MHz to 3 GHz
(3 to 9) GHz
(9 to 18) GHz
0.5 % of rdg + 0.01 rho
0.7 % of rdg + 0.018 rho
1.6 % of rdg + 0.035 rho
3.9 % of rdg + 0.043 rho
HP
8510C/8341A
synthesized
sweeper/cal kit
S-Parameter – S11/S22
Phase (Degrees)
100 kHz to 10 MHz, rho >0.025
100 kHz to 10 MHz, rho >0.1
10 MHz to 3 GHz, rho>0.05
10 MHz to 3 GHz, rho>0.1
(3 to 9) GHz, rho>0.1
(3 to 9) GHz, rho>0.2
(9 to 18) GHz, rho >0.2
12°
3.9°
9.5°
5.1°
12°
6°
17°
HP
8510C/8341A
synthesized
sweeper/cal kit
Attenuation – Measuring
Equipment, 1dB Steps
(1 to 3) dB, < 1 GHz
(1 to 3) dB, (1 to 11) GHz
(1 to 3) dB, (11 to 18) GHz
(4 to 7) dB, < 1 GHz
(4 to 7) dB, (1 to 11) GHz
(4 to 7) dB, (11 to 18) GHz
(8 to 11) dB, < 1 GHz
(8 to 11) dB, (1 to 11) GHz
(8 to 11) dB, (11 to 18) GHz
0.19 dB
0.20 dB
0.19 dB
0.17 dB
0.15 dB
0.24 dB
0.26 dB
0.27 dB
0.58 dB
HP8494H | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 16 of 21
Parameter/Range
Frequency
CMC2, 9 (±)
Comments
Attenuation – Measuring
Equipment, 10 dB Steps
(10 to 30) dB
(10 to 30) dB
(10 to 30) dB
(40 to 70) dB
(40 to 70) dB
(40 to 70) dB
<1 GHz
(1 to 11) GHz
(11 to 18) GHz
<1 GHz
(1 to 11) GHz
(11 to 18) GHz
0.24 dB
0.64 dB
1.6 dB
0.61 dB
0.66 dB
2.3 dB
HP8495H
RF Power – Measuring
Equipment
(+20 to -50) dBm
(+20 to -100) dBm
100 kHz to 10 MHz
10 MHz to 26.5 GHz
0.2 dB
1.1 dB
HP 3325B
generator
Anritsu
synthesizer
RF Power – Measure
(-20 to +20) dBm
(-1 to +20) dBm
100 kHz to 10 MHz
10 MHz to 26.5 GHz
0.73 dB
0.62 dB
E4417A
w/E9304A
E4417A
w/8487A | ||
| 17 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 17 of 21
Parameter/Equipment
Range
CMC2, 9 (±)
Comments
RF Tuned
Power/Attenuation –
Measure
(2.5 to 1300) MHz
(0 to -10) dB
(-10 to -20) dB
(-20 to -30) dB
(-30 to -40) dB
(-40 to -50) dB
(-50 to -60) dB
(-60 to -70) dB
(-70 to -80) dB
(-80 to -90) dB
(-90 to -100) dB
(-100 to -110) dB
(1.3 to 26.5) GHz
(0 to -10) dB
(-10 to -20) dB
(-20 to -30) dB
(-30 to -40) dB
(-40 to -50) dB
(-50 to -60) dB
(-60 to -70) dB
(-70 to -80) dB
(-80 to -90) dB
(-90 to -100) dB
(-100 to -110) dB
0.024 dB
0.033 dB
0.037 dB
0.042 dB
0.067 dB
0.077 dB
0.086 dB
0.091 dB
0.12 dB
0.12 dB
0.13 dB
0.035 dB
0.042 dB
0.046 dB
0.050 dB
0.072 dB
0.081 dB
0.090 dB
0.095 dB
0.12 dB
0.12 dB
0.13 dB
Agilent 8902A
receiver
Agilent 8902A
receiver w/
11793A
converter
Amplitude Modulation –
Measure
Rate: 50 Hz to 10 kHz
Depth: (5 to 99) %
Rate: 20 Hz to 10 kHz
Depth: (5 to 99) %
Rate: 50 Hz to 50 kHz
Depth: (5 to 99) %
Rate: 20 Hz to 100 kHz
Depth: (5 to 99) %
Rate: 50 Hz to 50 kHz
Depth: (5 to 99) %
Rate: 50 Hz to 50 kHz
Depth: (5 to 99) %
(0.15 to 10) MHz
(0.15 to 10) MHz
(0.01 to 1.3) GHz
(0.01 to 1.3) GHz
(1.3 to 26.5) GHz
(1.3 to 26.5) GHz
2.4 %
3.6 %
1.3 %
3.6 %
1.9 %
3.6 %
Agilent 8902A
receiver
Agilent 8902A
receiver w/
11793A
converter | 2.5 to 1300 MHz |
| 18 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 18 of 21
Parameter/Equipment
Range
CMC2, 9 (±)
Comments
Frequency Modulation –
Measure
Rate: 20 Hz to 10 kHz
Dev: ≤40 kHz peak
Rate: 50 Hz to 100 kHz
Dev: ≤400 kHz peak
Rate: 20 Hz to 200 kHz
Dev: ≤4.0 kHz peak
Rate: 50 Hz to 100 kHz
Dev: ≤400 kHz peak
Rate: 20 Hz to 200 kHz
Dev: ≤400 kHz peak
(0.15 to 10) MHz
(0.01 to 1.3) GHz
(0.01 to 1.3) GHz
(1.3 to 26.5) GHz
(1.3 to 26.5) GH
2.5 %
1.4 %
6.1 %
1.4 %
6.1 %
Agilent 8902A receiver
Agilent 8902A receiver w/
11793A converter
Phase Modulation –
Measure
Rate: 200 Hz to 10 kHz
Rate: 200 Hz to 20 kHz
(0.15 to 10) MHz
(0.01 to 26.5) GHz
4.9 %
3.7 %
Agilent 8902A receiver
IV. Mechanical
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Force – Compression 3
Up to 50 lbf
(50 to 500) lbf
(500 to 2000) lbf
(2000 to 5000) lbf
(5000 to 20 000) lbf
0.032 lbf
0.061 %
0.096 %
0.16 %
0.3 %
NIST Class F weights
Tovey SSC-500 load cell
Tovey SSC-2K load cell
Sensotec 41/0572
load cell
Lebow 3194-20K load
cell | to 20000 lbf |
| 19 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 19 of 21
Parameter/Equipment
Range
CMC2, 5, 9 (±)
Comments
Force – Tension
3
Up to 60 lbf
(60 to 500) lbf
(500 to 2000) lbf
0.032 lbf
0.061 %
0.096 %
NIST Class F weights
Tovey SSC-500 load cell
Tovey SSC-2K load cell
Torque Transducers
(1 to 500) ozfꞏin
(30 to 2000) lbfꞏin
(150 to 1000) lbfꞏft
0.16 ozfꞏin
0.24 lbfꞏin
0.15 lbfꞏft
Torque wheel, weights
Torque arm, weights
Torque Wrenches
3
(0.5 to 215) ozfꞏin
(20 to 200) ozfꞏin
(5 to 50) lbfꞏin
(30 to 400) lbfꞏin
(80 to 1000) lbfꞏin
(20 to 250) lbfꞏft
(250 to 600) lbfꞏft
(600 to 1000) lbfꞏft
1.4 %
0.61 %
0.81 %
0.61 %
0.62 %
0.70 %
0.85 %
1.2 %
Lebow 2120-200 torque cell
CDI torque system
Lebow 2133-106 torque cell
Scales & Balances
3, 8
(1, 2, 5, 10, 20) mg
(50, 100, 200, 500) mg
(1, 2, 5) g
(10, 20) g
50 g to 10 kg
(1 to 20) lb
(1 to 1200) lb
30 µg + 0.58R
30 µg + 0.58R
50 µg + 0.58R
0.001 % + 0.58R
0.0005 % + 0.58R
0.0002 % + 0.58R
0.012 % + 0.58R
NIST Class S weights
Comparison using Class F
weights
Pressure – Measuring
Equipment
3
(0.01 to 150) psia
(4 to 204) inH2O
(5 to 10 000) psig
0.02 psi
0.06 %
0.02 %
Mensor 2101
digital pressure gage
Ametek PK104WC
deadweight tester
Pressurements
deadweight tester | ||
| 20 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 20 of 21
V. Thermodynamics
Parameter/Equipment
Range
CMC2, 9 (±)
Comments
Temperature – Measure
(-197 to 200) °C
(200 to 660) °C
0.033 °C
0.054 °C
Fluke 1524 w/PRT
Temperature – Measuring
Equipment
(-40 to -25) °C
(-25 to 140) °C
(140 to 425) °C
0.08 °C
0.042 °C
0.36 °C
Calibration baths & dry
wells
VI. Time & Frequency
Parameter/Equipment
Range
CMC
2, 9
(±)
Comments
Frequency – Measure
1 Hz to 10 MHz
2.9 pHz/Hz
Datum 9390-6000,
ExacTime GPS
Frequency – Measuring
Equipment
10 MHz
62 pHz/Hz
Datum 9390-6000,
ExacTime GPS
Keysight 53131A
Stopwatches & Timers3
(0 to 19.99) s/day
0.043 s/day
Timometer 4500
_________________________________________________
1
This laboratory offers commercial cal ibration and field calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standard s or nearly ideal measuring equipment. CMCs
represent expanded uncertainties expressed at approx imately the 95 % level of confidence, usually using
a coverage factor of k = 2. The actual measurem ent uncertainty of a specific calibration performed by
the laboratory may be greater than the CMC due to the behavior of the customer’s device and to
influences from the circumstances of the specific calibration.
3 Field calibration service is available for this calibr ation. Please note the actual measurement uncertainties
achievable on a customer's site can normally be exp ected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the pl ace of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on it s own, could result in the actual measurement uncertainty achievable
on a customer’s site being larger than the CMC. | ||
| 21 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 21 of 21
4 In the statement of CMC, L is the numerical values of the nominal length in inches , t is the numerical
value of the nominal time in seconds .
5 In the statement of CMC, the value is defined as the percentage of reading.
6 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges
indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction
of the reading plus a fixed floor specification.
7 The stated uncertainty is the laboratory’s ability to source a fast rise pulse that is approximately 250 ps. In
the typical application of measuring rise time of an oscilloscope, this value is one of the contributing factors,
but other factors are derived from the Device Under Test.
8 The CMC for scales and balances is highly dependent upon the resolution of the unit under test. The
uncertainties presented here do not include the resolu tion of the unit under test. The resolution will be
included in the reported measurement uncertainty at the time of calibration.
9 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory
is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed
measurement parameter.
10 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 22 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Assured Testing ServicesRidgway, PA · ~204 kmA2LAShares 1 accredited materialOil
- Process InstrumentsPittsburgh, PA · ~351 kmA2LAShares 1 accredited materialOil
- Alpha Technologies ServicesHudson, OH · ~373 kmA2LAShares 1 accredited materialOil
- ALS OIL & LUBRICANTS (TRIBOLOGY)Valley View, OH · ~376 kmA2LAShares 1 accredited materialOil
- AmSpecMickleton, NJ · ~414 kmA2LAShares 1 accredited materialOil
Accreditation data refreshed from the A2LA register on .