Registers refreshed 2026-11-20.See refresh dates
United States

CalSource

235 Middle road Suite 100, 14467, Henrietta, NY, United States

Visit website
A2LA 2133.02ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
22
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 22 scope lines.

A2LA certificate 2133.02 · 22 lines

LineMethodMatrixRange
1ISO 17025:2017-to 72 in
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 2 of 21 Parameter/Equipment Range CMC2 (±) Comments Cylindrical Outside Diameter Up to 4 in 11 μin Mahr 828 bench micrometer Cylindrical Inside Diameter Up to 1 in (1 to 4) in (4 to 6) in (6 to 10) in 21 μin 35 μin 51 μin 82 μin Zeiss universal measuring machine, master ring gages Thread Plugs – Pitch Diameter (6 to 120) TPI Up to 1 in (1 to 10) in 57 μin 83 μin Bench micrometer, gage blocks, thread wires II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC 2, 6 (±) Comments DC Voltage3 – Measure Up to 100 mV 100 mV to 1 V (1 to 10) V (10 to 100) V 100 V to 1 kV (1 to 10) kV (20 to 35) kV 12 μV/V + 0.3 μV 5.8 μV/V + 0.3 μV 4.2 μV/V + 0.5 μV 9.6 μV/V + 30 μV 11 μV/V + 0.1 mV 0.043 % + 0.03 V 0.04 % + 0.7 V HP 3458A Opt 002 8.5 digit multimeter Vitrek 4700 high voltage meter DC Voltage3 – Generate Up to 220 mV 220 mV to 2.2 V (2.2 to 11) V (11 to 22) V (22 to 220) V 220 V to 1.1 kV 11 μV/V + 0.4 μV 6.4 μV/V + 0.7 μV 5.4 μV/V + 2.5 μV 5.3 μV/V + 4 μV 8.6 μV/V + 50 μV 10 μV/V + 0.5 mV Fluke 5720A multiproduct calibrator
to 4 in
3-Oil
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 3 of 21 Parameter/Equipment Range CMC2, 6 (±) Comments DC Current3 – Measure Up to 100 nA 100 nA to 1 μA (1 to 10) μA (10 to 100) μA 100 μA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A 30 μA/A + 40 pA 30 μA/A + 40 pA 26 μA/A + 0.1 nA 25 μA/A + 0.8 nA 24 μA/A + 5 nA 24 μA/A + 50 nA 42 μA/A + 0.5 μA 0.14 mA/A + 10 μA HP 3458A Opt 002 8.5 digit multimeter DC Current – Generate 3 Up to 220 μA 220 μA to 2.2 mA (2.2 to 22) mA (22 to 220) mA 220 mA to 2.2 A (2.2 to 11) A (11 to 20.5) A 41 μA/A + 6 nA 39 μA/A + 7 nA 39 μA/A + 40 nA 46 μA/A + 0.7 μA 130 μA/A + 12 μA 0.57 mA/A + 0.48 mA 1.1 mA/A + 0.75 mA Fluke 5720A multiproduct calibrator, Fluke 5725A amplifier Fluke 5520A multiproduct calibrator Multiproduct Calibrator DC Current Clamp – Generate 3 (Non- Toroidal) (20 to 150) A (150 to 1000) A 0.96 % + 0.14 A 2.5 % + 0.5 A Fluke 5520A multiproduct calibrator, Fluke 5500A/COIL 50-turn coil Parameter/Range Frequency CMC2, 6 (±) Comments AC Voltage – Measure 3 (1 to 10) mV (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz 0.35 mV/V + 3 μV 0.25 mV/V + 1.1 μV 0.37 mV/V + 1.1 μV 1.2 mV/V + 1.1 μV 5.8 mV/V + 1.1 μV 47 mV/V + 2 μV 14 mV/V + 5 μV HP 3458A Opt 002 8.5 digit multimeter
to 1000 A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 4 of 21 Parameter/Range Frequency CMC2, 6 (±) Comments AC Voltage – Measure 3 (cont) (10 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (2 to 4) MHz (4 to 8) MHz (8 to 10) MHz 1 to 40) Hz 40 Hz to 1kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (2 to 4) MHz (4 to 8) MHz (8 to 10) MHz (1 to 40) Hz 40 Hz to 1kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (2 to 4) MHz (4 to 8) MHz (8 to 10) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz 93 μV/V + 4 μV 88 μV/V + 2 μV 0.17 mV/V + 2 μV 0.36 mV/V + 2 μV 0.93 mV/V + 2 μV 3.5 mV/V + 10 μV 12 mV/V + 10 μV 18 mV/V + 10 μV 47 mV/V + 70 μV 47 mV/V + 80 μV 0.18 V/V + 0.1 mV 93 μV/V + 40 μV 86 μV/V + 20 μV 0.17 mV/V + 20 μV 0.36 mV/V + 20 μV 0.93 mV/V + 20 μV 3.5 mV/V + 0.1 mV 12 mV/V + 0.1 mV 18 mV/V + 0.1 mV 47 mV/V + 0.7 mV 47 mV/V + 0.8 mV 0.18 V/V + 1 mV 93 μV/V + 0.4 mV 86 μV/V + 0.2 mV 0.17 mV/V + 0.2 mV 0.36 mV/V + 0.2 mV 0.93 mV/V + 0.2 mV 3.5 mV/V + 1 mV 12 mV/V + 1 mV 18 mV/V + 1 mV 47 mV/V + 7 mV 47 mV/V + 8 mV 0.18 V/V + 10 mV 0.24 mV/V + 4 mV 0.24 mV/V + 2 mV 0.24 mV/V + 2 mV 0.41 mV/V + 2 mV 1.4 mV/V + 2 mV 4.7 mV/V + 10 mV 18 mV/V + 10 mV HP 3458A Opt 002 8.5 digit multimeter
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 5 of 21 Parameter/Range Frequency CMC2, 6 (±) Comments AC Voltage – Measure 3 (cont) (100 to 700) V (1.1 to 10) kV (10 to 35) kV (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 50 Hz 50 Hz 0.49 mV/V + 28 mV 0.48 mV/V + 14 mV 0.71 mV/V + 14 mV 1.4 mV/V + 14 mV 3.5 mV/V + 14 mV 0.15 % + 0.1V 0.12 % + 0.2 V HP 3458A Opt 002 8.5 digit multimeter Vitrek 4700 high voltag e meter AC Voltage – Generate 3 Up to 2.2 mV (2.2 to 22) mV (22 to 220) mV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz 0.067 % + 4 μV 0.082 % + 4 μV 0.067 % + 4 μV 0.12 % + 4 μV 0.19 % + 5 μV 0.35 % + 10 μV 0.5 % + 20 μV 0.68 % + 20 μV 0.041 % + 4 μV 0.017 % + 4 μV 0.016 % + 4 μV 0.033 % + 4 μV 0.071 % + 5 μV 0.15 % + 10 μV 0.2 % + 20 μV 0.36 % + 20 μV 0.03 % + 12 μV 0.012 % + 7 μV 0.011 % + 7 μV 0.025 % + 7 μV 0.057 % + 17 μV 0.11 % + 20 μV 0.17 % + 25 μV 0.33 % + 45 μV Fluke 5720A multiproduct calibrator
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 6 of 21 Parameter/Range Frequency CMC2, 6 (±) Comments AC Voltage – Generate3 (cont) 220 mV to 2.2 V (2.2 to 22) V (22 to 220) V 220 V to 1.1 kV 750 V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (15 to 50) Hz 50 Hz to 1 kHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 30) kHz (30 to 50) kHz (50 to 100) kHz 0.28 mV/V + 40 μV 0.11 mV/V + 15 μV 53 μV/V + 8 μV 0.10 mV/V + 10 μV 0.15 mV/V + 30 μV 0.52 mV/V + 80 μV 1.2 mV/V + 0.2 mV 2.2 mV/V + 0.3 mV 0.28 mV/V + 0.40 mV 0.11 mV/V + 0.15 mV 53 μV/V + 50 μV 88 µV/V + 0.1 mV 0.12 mV/V + 0.2 mV 0.33 mV/V + 0.6 mV 1.2 mV/V + 2 mV 1.8 mV/V + 3.2 mV 0.28 mV/V + 4 mV 0.11 mV/V + 1.5 mV 61 μV/V + 0.6 mV 94 µV/V + 1 mV 0.18 mV/V + 2.5 mV 1.1 mV/V + 16 mV 5.1 mV/V + 40 mV 8.7 mV/V + 80 mV 0.35 mV/V + 16 mV 82 μV/V + 3.5 mV 0.11 mV/V + 4 mV 0.2 mV/V + 6 mV 0.7 mV/V + 11 mV 0.7 mV/V + 11 mV 2.7 mV/V + 45 mV Fluke 5720A multiproduct calibrator Fluke 5720A Fluke 5720A w/5725A amplifier
7--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 7 of 21 Parameter/Range Frequency CMC2, 6 (±) Comments AC Current –Measure3 Up to 100 μA (1 to 100) mA 100 mA to 1 A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 1 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz 4.6 mA/A + 30 nA 1.8 mA/A + 30 nA 0.7 mA/A + 30 nA 0.7 mA/A + 30 nA 4.6 mA/A + 20 μA 1.8 mA/A + 20 μA 0.7 mA/A + 20 μA 0.36 mA/A + 20 μA 4.6 mA/A + 0.2 mA 1.9 mA/A + 0.2 mA 0.93 mA/A + 0.2 mA 1.2 mA/A + 0.2 mA HP 3458A Opt 002 8.5 digit multimeter AC Current – Generate3 Up to 220 μA 220 μA to 2.2 mA (2.2 to 22) mA (22 to 220) mA 220 mA to 2.2 A (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 20 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.046 % + 16 nA 0.042 % + 10 nA 0.041 % + 8 nA 0.049 % + 12 nA 0.12 % + 65 nA 0.051 % + 40 nA 0.045 % + 35 nA 0.043 % + 35 nA 0.046 % + 0.11 μA 0.14 % + 0.65 μA 0.051 % + 0.4 μA 0.045 % + 0.35 μA 0.043 % + 0.35 μA 0.047 % + 0.55 μA 0.14 % + 5 μA 0.047 % + 4 μA 0.043 % + 3.5 μA 0.042 % + 2.5 μA 0.045 % + 3.5 μA 0.12 % + 10 μA 0.08 % + 35 μA 0.09 % + 80 μA 0.82 % + 0.16 mA Fluke 5720A multiproduct calibrator
to 1 A
8-Oil
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 8 of 21 Parameter/Range Frequency CMC2, 6 (±) Comments AC Current – Generate3 (cont) (2.2 to 11) A (11 to 20.5) A 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz 0.12 % + 0.17 mA 0.16 % + 0.38 mA 0.43 % + 0.75 mA 0.3 % + 5 mA 0.26 % + 5 mA 0.6 % + 5 mA Fluke 5720A multiproduct calibrator, Fluke 5725A amplifier Fluke 5520A multiproduct calibrator AC Current Clamp – Generate 3 (Non- Toroidal) (20 to 150) A (150 to 1000) A (45 to 65) Hz (65 to 400) Hz (45 to 65) Hz (65z to 400) Hz 0.97 % + 0.25 A 1.4 % + 0.25A 1.3 % + 0.9 A 1.8 % + 0.9 A Fluke 5520A multiproduct calibrator, Fluke 5500A/COIL 50-turn coil AC Current Clamp – Generate 3 (Toroidal) (20 to 150) A (150 to 1000) A (45 to 65) Hz (65 to 400) Hz (45 to 65) Hz (65 to 400) Hz 0.56 % + 0.025 A 1.1 % + 0.027A 1.2 % + 0.09 A 1.7 % + 0.1 A
See scope document
9--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 9 of 21 Parameter/Equipment Range CMC2, 5, 6 (±) Comments Resistance – Generate3 0 Ω 1 Ω 1.9 Ω 10 Ω 19 Ω 100 Ω 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 42 μΩ 0.1 mΩ/Ω 0.12 mΩ/Ω 24 μΩ/Ω 26 μΩ/Ω 14 μΩ/Ω 14 μΩ/Ω 13 μΩ/Ω 13 μΩ/Ω 13 μΩ/Ω 13 μΩ/Ω 15 μΩ/Ω 15 μΩ/Ω 18 μΩ/Ω 45 μΩ/Ω 45 μΩ/Ω 51 μΩ/Ω 0.13 mΩ/Ω Fluke 5720A multiproduct calibrator Resistance3 – Generate Up to 11 Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω 330 Ω to 1.1 kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ 330 kΩ to 1.1 MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ 330 MΩ to 1.1 GΩ 28 µΩ/Ω + 0.001 Ω 21 µΩ/Ω + 0.0015 Ω 21 µΩ/Ω + 0.0014 Ω 21 µΩ/Ω + 0.002 Ω 21 µΩ/Ω + 0.002 Ω 21 µΩ/Ω + 0.02 Ω 21 µΩ/Ω + 0.02 Ω 22 µΩ/Ω + 0.2 Ω 21 µΩ/Ω + 0.2 Ω 24 µΩ/Ω + 2 Ω 24 µΩ/Ω + 2 Ω 60 µΩ/Ω + 30 Ω 90 µΩ/Ω + 50 Ω 0.017 % + 2.5 kΩ 0.036 % 0.45 % 1.1 % Fluke 5520A Resistance – Generate 3 (Fixed Artifacts) 10 mΩ 100 mΩ 1 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ 100 kΩ 1 MΩ 12 μΩ/Ω + 0.1 nΩ 12 μΩ/Ω 12 μΩ/Ω 12 μΩ/Ω 12 μΩ/Ω 12 μΩ/Ω 12 μΩ/Ω 23 μΩ/Ω 0.12 mΩ/Ω L&N 4222 resistor L&N 4015-B resistor L&N 4020-B resistor L&N 8070/10 resistor L&N 100 resistor Gray 1000 resistor Gray 10000 resistor L&N 4045-B resistor ESI SR-1 resistor
to 1100000000 Ω
10--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 10 of 21 Parameter/Equipment Range CMC2, 5, 6 (±) Comments Resistance – Measure3 Up to 10 Ω (10 to 100) Ω 100 Ω to 1 kΩ (1 to 10) kΩ (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ (10 to 100) MΩ 100 MΩ to 1 GΩ 23 μΩ/Ω + 0.1 mΩ 23 μΩ/Ω + 1 mΩ 18 μΩ/Ω + 1 mΩ 18 μΩ/Ω + 10 mΩ 18 μΩ/Ω + 0.1 Ω 23 μΩ/Ω + 4 Ω 87 μΩ/Ω + 0.1 kΩ 1.2 mΩ/Ω + 1 kΩ 12 mΩ/Ω + 10 kΩ HP 3458A Opt 002 8.5 digit multimeter Parameter/Range Frequency CMC2, 6 (±) Comments Capacitance – Measure 100 pF to 100 µF (100 to 500) µF (100 to 1000) µF (1000 to 3300) µF 100 pF to 100 nF 100 nF to 100 µF (100 to 1000) µF 1 kHz Only 1 kHz Only 1 kHz Only 1 kHz Only 500 Hz to 10 kHz 12 Hz to 10 kHz 50 Hz to 2 kHz 0.07 % 0.25 % 0.48 % 1.5 % 0.20 % 0.20 % 1.9 % Genrad 1689 Parameter/Equipment Range CMC2, 5, 6 (±) Comments Capacitance – Generate3 (Simulation) (0.19 to 3.3) nF (3.3 to 11) nF (11 to 110) nF (110 to 330) nF (0.33 to 1.1) μF (1.1 to 3.3) μF (3.3 to 11) μF (11 to 33) μF (33 to 110) μF (110 to 330) μF (0.33 to 1.1) mF (1.1 to 3.3) mF (3.3 to 11) mF (11 to 33) mF (33 to 110) mF 0.37 % + 0.01 nF 0.28 % + 0.01 nF 0.23 % + 0.1 nF 0.23 % + 0.3 nF 0.23 % + 1 nF 0.23 % + 3 nF 0.24 % + 10 nF 0.32 % + 30 nF 0.34 % + 100 nF 0.35 % + 300 nF 0.35 % + 1 μF 0.32 % + 3 μF 0.32 % + 10 μF 0.52 % + 30 μF 0.81 % + 100 μF Fluke 5520A multiproduct calibrator
to 10 Ω
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 11 of 21 Parameter/Range Frequency CMC2, 6 (±) Comments Capacitance – Generate3 (Fixed Artifacts) 100 pF 1 nF 1 kHz 0.0024 pF 0.024 pF Standard capacitors General Radio 1404-B General Radio 1404-A Inductance – Measure 100 μH to 10 H 100 Hz & 1 kHz 0.3 mH/H General Radio 1689M RLC bridge Inductance – Generate 3 (Fixed Artifacts) 100 μH 1 mH 10 mH 100 mH 1 H 100 Hz & 1 kHz 0.31 μH 1.2 μH 16 μH 0.12 mH 1.3 mH Standard inductors General Radio 1482B General Radio 1482E General Radio 1482H General Radio 1482L General Radio 1482P Phase 3 – Generate (Dual ACV Outputs) 3.3V, PF 0 to 1 (0 to 90)° 3.3V, PF 1 (0 to 90)° (10 to 65) Hz (65 to 500) Hz 500 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.07° 0.17° 0.34° 1.7° 3.4° 6.7° Fluke 5520A
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 12 of 21 Parameter/Equipment Range CMC2, 4 (±) Comments Oscilloscopes3, 7 Leveled Sine Wave 50 kHz Reference 50 kHz Reference 10 Hz to 100 kHz: Into 1 MΩ Load Into 50 Ω Load Rise Time Source 250 ps Nominal Time Marker Into 50 Ω Load 5 mV to 5 V p-p 5 mV to 5.5 V p-p 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (0 to 33) V p-p (0 to 6.5) V p-p 4 mVp-p to 2.5 Vp-p 1 kHz to 10 MHz 2 ns to 20 ms 50 ms to 5 s 23 mV/V + 300 μV 20 mV/V + 0.1 mV 25 mV/V + 0.1 mV 47 mV/V + 0.1 mV 35 mV/V + 0.1 mV 35 mV/V + 0.1 mV 50 ps 2.5 μs/s (25 + 1000t) μs Fluke 5520A/6 multiproduct calibrator with 600 MHz scope option Electrical Simulation of Thermocouples & Thermocouple Indicators 3 – Type B Type C Type E (600 to 800) °C (800 to 1000) °C (1000 to 1550) °C (1550 to 1820) °C (0 to 150) °C (150 to 650) °C (650 to 1000) °C (1000 to 1800) °C (1800 to 2316) °C (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C 0.34 °C 0.27 °C 0.24 °C 0.26 °C 0.24 °C 0.21 °C 0.25 °C 0.39 °C 0.65 °C 0.39 °C 0.13 °C 0.12 °C 0.13 °C 0.17 °C Fluke 5520A
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 13 of 21 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouples & Thermocouple Indicators 3 – (cont) Type J Type K Type L Type N Type R Type S Type T Type U (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 °C to 120) °C (120 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to 800) °C (800 to 900) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C (-200 to 0) °C (0 to 400) °C 0.22 °C 0.13 °C 0.12 °C 0.14 °C 0.19 °C 0.26 °C 0.15 °C 0.13 °C 0.21 °C 0.32 °C 0.29 °C 0.21 °C 0.14 °C 0.32 °C 0.18 °C 0.15 °C 0.15 °C 0.22 °C 0.45 °C 0.28 °C 0.26 °C 0.32 °C 0.37 °C 0.28 °C 0.30 °C 0.37 °C 0.50 °C 0.20 °C 0.14 °C 0.12 °C 0.44 °C 0.22 °C Fluke 5520A
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 14 of 21 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of RTD Indicating Devices – Generate 3 Pt 385, 100 Ω Pt 3926, 100 Ω Pt 3916, 100 Ω Pt 385, 200 Ω Pt 385, 500 Ω Pt 385, 1000 Ω PtNi 385, 120 Ω (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-200 to -190) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 100) °C (100 to 260) °C (260 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 600) °C (600 to 630) °C (-80 to100) °C (100 to 260) °C 0.06 °C 0.09 °C 0.11 °C 0.12 °C 0.14 °C 0.27 °C 0.06 °C 0.09 °C 0.11 °C 0.12 °C 0.14 °C 0.29 °C 0.05 °C 0.06 °C 0.07 °C 0.08 °C 0.1 °C 0.11 °C 0.12 °C 0.27 °C 0.05 °C 0.06 °C 0.14 °C 0.15 °C 0.17 °C 0.19 °C 0.05 °C 0.06 °C 0.07 °C 0.1 °C 0.11 °C 0.13 °C 0.04 °C 0.05 °C 0.06 °C 0.07 °C 0.08 °C 0.27 °C 0.09 °C 0.17 °C Fluke 5520A multiproduct calibrator
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 15 of 21 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of RTD Indicating Devices – Generate 3 (cont) Cu 427, 10 Ω (-100 to 260) °C 0.35 °C Fluke 5520A multiproduct calibrator III. Electrical – RF/Microwave Parameter/Equipment Range CMC2, 9 (±) Comments RF Power Reference 1 mW, 50 MHz 0.03 mW HP 8478 w/ 432B & 3458A RF Power Sensor Calibration Factors 100 kHz to 4.6 GHz (4.6 to 18) GHz 1.0 % 1.7 % Tegam F1130A, Tegam 1830A S-Parameter – S11/S22 Magnitude (linear) 100 kHz to 10 MHz 10 MHz to 3 GHz (3 to 9) GHz (9 to 18) GHz 0.5 % of rdg + 0.01 rho 0.7 % of rdg + 0.018 rho 1.6 % of rdg + 0.035 rho 3.9 % of rdg + 0.043 rho HP 8510C/8341A synthesized sweeper/cal kit S-Parameter – S11/S22 Phase (Degrees) 100 kHz to 10 MHz, rho >0.025 100 kHz to 10 MHz, rho >0.1 10 MHz to 3 GHz, rho>0.05 10 MHz to 3 GHz, rho>0.1 (3 to 9) GHz, rho>0.1 (3 to 9) GHz, rho>0.2 (9 to 18) GHz, rho >0.2 12° 3.9° 9.5° 5.1° 12° 6° 17° HP 8510C/8341A synthesized sweeper/cal kit Attenuation – Measuring Equipment, 1dB Steps (1 to 3) dB, < 1 GHz (1 to 3) dB, (1 to 11) GHz (1 to 3) dB, (11 to 18) GHz (4 to 7) dB, < 1 GHz (4 to 7) dB, (1 to 11) GHz (4 to 7) dB, (11 to 18) GHz (8 to 11) dB, < 1 GHz (8 to 11) dB, (1 to 11) GHz (8 to 11) dB, (11 to 18) GHz 0.19 dB 0.20 dB 0.19 dB 0.17 dB 0.15 dB 0.24 dB 0.26 dB 0.27 dB 0.58 dB HP8494H
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 16 of 21 Parameter/Range Frequency CMC2, 9 (±) Comments Attenuation – Measuring Equipment, 10 dB Steps (10 to 30) dB (10 to 30) dB (10 to 30) dB (40 to 70) dB (40 to 70) dB (40 to 70) dB <1 GHz (1 to 11) GHz (11 to 18) GHz <1 GHz (1 to 11) GHz (11 to 18) GHz 0.24 dB 0.64 dB 1.6 dB 0.61 dB 0.66 dB 2.3 dB HP8495H RF Power – Measuring Equipment (+20 to -50) dBm (+20 to -100) dBm 100 kHz to 10 MHz 10 MHz to 26.5 GHz 0.2 dB 1.1 dB HP 3325B generator Anritsu synthesizer RF Power – Measure (-20 to +20) dBm (-1 to +20) dBm 100 kHz to 10 MHz 10 MHz to 26.5 GHz 0.73 dB 0.62 dB E4417A w/E9304A E4417A w/8487A
17--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 17 of 21 Parameter/Equipment Range CMC2, 9 (±) Comments RF Tuned Power/Attenuation – Measure (2.5 to 1300) MHz (0 to -10) dB (-10 to -20) dB (-20 to -30) dB (-30 to -40) dB (-40 to -50) dB (-50 to -60) dB (-60 to -70) dB (-70 to -80) dB (-80 to -90) dB (-90 to -100) dB (-100 to -110) dB (1.3 to 26.5) GHz (0 to -10) dB (-10 to -20) dB (-20 to -30) dB (-30 to -40) dB (-40 to -50) dB (-50 to -60) dB (-60 to -70) dB (-70 to -80) dB (-80 to -90) dB (-90 to -100) dB (-100 to -110) dB 0.024 dB 0.033 dB 0.037 dB 0.042 dB 0.067 dB 0.077 dB 0.086 dB 0.091 dB 0.12 dB 0.12 dB 0.13 dB 0.035 dB 0.042 dB 0.046 dB 0.050 dB 0.072 dB 0.081 dB 0.090 dB 0.095 dB 0.12 dB 0.12 dB 0.13 dB Agilent 8902A receiver Agilent 8902A receiver w/ 11793A converter Amplitude Modulation – Measure Rate: 50 Hz to 10 kHz Depth: (5 to 99) % Rate: 20 Hz to 10 kHz Depth: (5 to 99) % Rate: 50 Hz to 50 kHz Depth: (5 to 99) % Rate: 20 Hz to 100 kHz Depth: (5 to 99) % Rate: 50 Hz to 50 kHz Depth: (5 to 99) % Rate: 50 Hz to 50 kHz Depth: (5 to 99) % (0.15 to 10) MHz (0.15 to 10) MHz (0.01 to 1.3) GHz (0.01 to 1.3) GHz (1.3 to 26.5) GHz (1.3 to 26.5) GHz 2.4 % 3.6 % 1.3 % 3.6 % 1.9 % 3.6 % Agilent 8902A receiver Agilent 8902A receiver w/ 11793A converter
2.5 to 1300 MHz
18--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 18 of 21 Parameter/Equipment Range CMC2, 9 (±) Comments Frequency Modulation – Measure Rate: 20 Hz to 10 kHz Dev: ≤40 kHz peak Rate: 50 Hz to 100 kHz Dev: ≤400 kHz peak Rate: 20 Hz to 200 kHz Dev: ≤4.0 kHz peak Rate: 50 Hz to 100 kHz Dev: ≤400 kHz peak Rate: 20 Hz to 200 kHz Dev: ≤400 kHz peak (0.15 to 10) MHz (0.01 to 1.3) GHz (0.01 to 1.3) GHz (1.3 to 26.5) GHz (1.3 to 26.5) GH 2.5 % 1.4 % 6.1 % 1.4 % 6.1 % Agilent 8902A receiver Agilent 8902A receiver w/ 11793A converter Phase Modulation – Measure Rate: 200 Hz to 10 kHz Rate: 200 Hz to 20 kHz (0.15 to 10) MHz (0.01 to 26.5) GHz 4.9 % 3.7 % Agilent 8902A receiver IV. Mechanical Parameter/Equipment Range CMC2, 5 (±) Comments Force – Compression 3 Up to 50 lbf (50 to 500) lbf (500 to 2000) lbf (2000 to 5000) lbf (5000 to 20 000) lbf 0.032 lbf 0.061 % 0.096 % 0.16 % 0.3 % NIST Class F weights Tovey SSC-500 load cell Tovey SSC-2K load cell Sensotec 41/0572 load cell Lebow 3194-20K load cell
to 20000 lbf
19

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 19 of 21 Parameter/Equipment Range CMC2, 5, 9 (±) Comments Force – Tension 3 Up to 60 lbf (60 to 500) lbf (500 to 2000) lbf 0.032 lbf 0.061 % 0.096 % NIST Class F weights Tovey SSC-500 load cell Tovey SSC-2K load cell Torque Transducers (1 to 500) ozfꞏin (30 to 2000) lbfꞏin (150 to 1000) lbfꞏft 0.16 ozfꞏin 0.24 lbfꞏin 0.15 lbfꞏft Torque wheel, weights Torque arm, weights Torque Wrenches 3 (0.5 to 215) ozfꞏin (20 to 200) ozfꞏin (5 to 50) lbfꞏin (30 to 400) lbfꞏin (80 to 1000) lbfꞏin (20 to 250) lbfꞏft (250 to 600) lbfꞏft (600 to 1000) lbfꞏft 1.4 % 0.61 % 0.81 % 0.61 % 0.62 % 0.70 % 0.85 % 1.2 % Lebow 2120-200 torque cell CDI torque system Lebow 2133-106 torque cell Scales & Balances 3, 8 (1, 2, 5, 10, 20) mg (50, 100, 200, 500) mg (1, 2, 5) g (10, 20) g 50 g to 10 kg (1 to 20) lb (1 to 1200) lb 30 µg + 0.58R 30 µg + 0.58R 50 µg + 0.58R 0.001 % + 0.58R 0.0005 % + 0.58R 0.0002 % + 0.58R 0.012 % + 0.58R NIST Class S weights Comparison using Class F weights Pressure – Measuring Equipment 3 (0.01 to 150) psia (4 to 204) inH2O (5 to 10 000) psig 0.02 psi 0.06 % 0.02 % Mensor 2101 digital pressure gage Ametek PK104WC deadweight tester Pressurements deadweight tester
20

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 20 of 21 V. Thermodynamics Parameter/Equipment Range CMC2, 9 (±) Comments Temperature – Measure (-197 to 200) °C (200 to 660) °C 0.033 °C 0.054 °C Fluke 1524 w/PRT Temperature – Measuring Equipment (-40 to -25) °C (-25 to 140) °C (140 to 425) °C 0.08 °C 0.042 °C 0.36 °C Calibration baths & dry wells VI. Time & Frequency Parameter/Equipment Range CMC 2, 9 (±) Comments Frequency – Measure 1 Hz to 10 MHz 2.9 pHz/Hz Datum 9390-6000, ExacTime GPS Frequency – Measuring Equipment 10 MHz 62 pHz/Hz Datum 9390-6000, ExacTime GPS Keysight 53131A Stopwatches & Timers3 (0 to 19.99) s/day 0.043 s/day Timometer 4500 _________________________________________________ 1 This laboratory offers commercial cal ibration and field calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standard s or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approx imately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurem ent uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibr ation. Please note the actual measurement uncertainties achievable on a customer's site can normally be exp ected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the pl ace of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on it s own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC.
21

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.02) Revised 01/10/2025 Page 21 of 21 4 In the statement of CMC, L is the numerical values of the nominal length in inches , t is the numerical value of the nominal time in seconds . 5 In the statement of CMC, the value is defined as the percentage of reading. 6 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 7 The stated uncertainty is the laboratory’s ability to source a fast rise pulse that is approximately 250 ps. In the typical application of measuring rise time of an oscilloscope, this value is one of the contributing factors, but other factors are derived from the Device Under Test. 8 The CMC for scales and balances is highly dependent upon the resolution of the unit under test. The uncertainties presented here do not include the resolu tion of the unit under test. The resolution will be included in the reported measurement uncertainty at the time of calibration. 9 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 10 This scope meets A2LA’s P112 Flexible Scope Policy.
22ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

235 Middle road Suite 100, Henrietta, NY, 14467, US

43.06118, -77.63390

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.