Nine Hee (Shanghai) Testing Technology
No.56 lane 328, Hengyong Road, Jiading District, Shanghai, People's Republic of China, Shanghai, China
- Accredited standards
- 10
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 10 standard numbers and the 8 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM E2919
ASTM F2853
ISO 1463Metallic and oxide coatings - Measurement of coating thickness - Microscopical method
ISO 2808Paints and varnishes - Determination of film thickness
ISO 5084Textiles - Determination of thickness of textiles and textile products
ISO 9227Corrosion tests in artificial atmospheres - Salt spray tests
ISO 9345Microscopes - Interfacing dimensions for imaging components
ISO 10360-13Geometrical product specifications (GPS) - Acceptance and reverification tests for coordinate measuring systems (CMS) - Part 13: Optical 3D CMS
ISO 13385-1Geometrical product specifications (GPS) - Dimensional measuring equipment - Part 1: Design and metrological characteristics of callipers
ISO 23529Rubber - General procedures for preparing and conditioning test pieces for physical test methods
ISO 2808; ISO 1463; ISO 9345; GB/T 34879; JJF (Min) 1101; ISO 10360-13; GB/T 16857.13; ASTM E2919; VDE 2634; GB/T30693; GB/T 22523
ISO 9227; GB/T 10125; SAE J2527; SAE J2412; FMVSS 302; CPSC:CHE1001-08.1; CPSC:CHE1001-08.2; CPSC:CHE1001-08.3; CPSC:CHE1002-08.2; CPSC:CHE1002-08.3; ASTM F2853; CPSC-CH-E1003-09.1; CPSC-CH-C1001-09.4; ISO 13385-1; JJG 30; SAE/USCAR-21; SAE/USCAR-2; GB/T 2941; ISO 23529; GB/T 3820; GB/T 45705; ISO 5084; JJG 34
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
5 lines
ISO/IEC 17025
Active7731.01
The scope document we hold says it is valid until 2027-12-31.
Accredited scope, certificate 7731.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; SAE/USCAR-21; SAE/USCAR-2 | Automotive Materials and Components, Polymer Composite Materials, Metals, Metal Fasteners, Paper, Plastics, Rubber, Laboratory Equipment, Electronic Displays, Radio Equipment, Solid-State Lighting Products, Bluetooth Devices and Household Appliances | - |
| 2 | SAE/USCAR-2 | - | - |
| 3 | ISO 9227; GB/T 10125; SAE J2527; SAE J2412; FMVSS 302; CPSC:CHE1001-08.1; CPSC:CHE1001-08.2; CPSC:CHE1001-08.3; CPSC:CHE1002-08.2; CPSC:CHE1002-08.3; ASTM F2853; CPSC-CH-E1003-09.1; CPSC-CH-C1001-09.4; ISO 13385-1; JJG 30; SAE/USCAR-21; SAE/USCAR-2; GB/T 2941; ISO 23529; GB/T 3820; GB/T 45705; ISO 5084; JJG 34 | - | See scope document |
| 4 | ISO 2808; ISO 1463; ISO 9345; GB/T 34879; JJF (Min) 1101; ISO 10360-13; GB/T 16857.13; ASTM E2919; VDE 2634; GB/T30693; GB/T 22523 | - | See scope document |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
NINE HEE (SHANGHAI) TESTING TECHNOLOGY CO. LTD
Jiading District, Shanghai, PROC
for technical competence in the field of
Mechanical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 13th day of February 2026.
__ _____________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 7731.01
Valid to December 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Labs with overlapping accredited scope in China
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.