SIMCO Electronics - Minneapolis

6537 Cecilia Circle, 55439, Bloomington, MN, United States

Visit website
A2LA 1395.14ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
15
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 15 scope lines.

A2LA certificate 1395.14 · 15 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.14) 07/29/2025 Page 2 of 14 Parameter/Equipment Range CMC2, 5 (±) Comments Adjustable Thread Ring Gages – Functional Diameter Up to 4 in for (8 to 80) TPI W Class Set Plug Tolerance Master setting plug Micrometers3 – Linearity Flatness Parallelism Up to 36 in Up to 1 in Up to 0.001 in 100 µin + 4.2L 7.4 µin 7.4 µin Gage blocks Optical flat Optical parallel Calipers3 Up to 40 in 180 µin + 4.2L Gage blocks Dial, Test, & Digital Indicators3 Up to 2 in Up to 6 in 15 µin + 2.4L 110 µin + 2.4L Gage blocks Electronic Gage Amplifiers (-0.01 to + 0.01) in 4.5 µin + 2.2L Gage blocks
to 40 in
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.14) 07/29/2025 Page 3 of 14 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 6, 7 (±) Comments DC Voltage3 – Generate (0 to 220) mV (0.22 to 2.2) V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1100) V 8.3 µV/V + 0.4 µV 5.3 µV/V + 0.7 µV 3.9 µV/V + 2.5 µV 3.8 µV/V + 4 µV 5.2 µV/V + 40 µV 6.7 µV/V + 400 µV Fluke 5720A series II DC Voltage3 – Measure (0 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V* 5.5 µV/V + 0.32 µV 4.3 µV/V + 0.32 µV 4.3 µV/V + 0.51 µV 6.2 µV/V + 32 µV 6.2 µV/V + 0.10 mV HP 3458A opt-2 *add 12(Vin/1000)2 106 to all Vin >100 V DC Current3 – Generate (0 to 220) µA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A (1.1 to 11) A (11 to 20) A 43 µA/A + 6.0 nA 55 µA/A + 7.0 nA 54 µA/A + 40 nA 62 µA/A + 0.7 μA 110 µA/A + 12 µA 0.05 % + 500 µA 0.1 % + 750 µA Fluke 5720A series II Fluke 5520A/SC1100 DC Current3 – Measure (0 to 1) µA (1 to 10) µA (10 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A 21 µA/A + 70 pA 21 µA/A + 300 pA 21 µA/A + 810 pA 21 µA/A + 5.1 nA 22 µA/A + 51 nA 36 µA/A + 510 nA 0.011 % + 10 µA HP 3458A opt-2 Resistance3 – Measure (0 to 10) Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ (0.1 to 1) GΩ 15 µΩ/Ω + 50 µΩ 12 µΩ/Ω + 0.5 mΩ 10 µΩ/Ω + 0.5 mΩ 10 µΩ/Ω + 5 mΩ 10 µΩ/Ω + 50 mΩ 16 µΩ/Ω + 2 Ω 82 µΩ/Ω + 100 Ω 0.051 % + 1 kΩ 0.5 % + 10 kΩ HP 3458A opt-2 Within ± 1 °C of last ACAL & ± 5 °C of TCAL
to 1100 V
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.14) 07/29/2025 Page 4 of 14 Parameter/Equipment Range CMC2, 5, 6, 7 (±) Comments Resistance3 – Generate Fixed Points 0 Ω (1, 1.9) Ω (10, 19) Ω (100, 190) Ω 1 kΩ (1.9, 19) kΩ (100, 190) kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 40 µΩ 95 µΩ/Ω 23 µΩ/Ω 31 µΩ/Ω 9 µΩ/Ω 9.7 µΩ/Ω 13 µΩ/Ω 21 µΩ/Ω 24 µΩ/Ω 44 µΩ/Ω 67 µΩ/Ω 240 µΩ/Ω Fluke 5720 series II Resistance3 – Generate (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (0.33 to 1.1) kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (0.33 to 1.1) MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (0.33 to 1.1) GΩ (1 to 10) GΩ (10 to 100) GΩ 100 GΩ to 1 TΩ 83 µΩ/Ω + 1 mΩ 59 µΩ/Ω + 1.5 mΩ 34 µΩ/Ω + 1.4 mΩ 31 µΩ/Ω + 2.0 mΩ 33 µΩ/Ω + 2.0 mΩ 31 µΩ/Ω + 20 mΩ 31 µΩ/Ω + 20 mΩ 31 µΩ/Ω + 200 mΩ 31 µΩ/Ω + 200 mΩ 41 µΩ/Ω + 2.0 Ω 39 µΩ/Ω + 2.0 Ω 83 µΩ/Ω + 30 Ω 0.015 % + 50 Ω 0.027 % + 2.5 kΩ 0.061 % + 3.0 kΩ 0.30 % + 0.1 MΩ 1.5 % + 0.5 MΩ 0.30 mΩ/Ω + 0.6R 3.6 mΩ/Ω + 0.6R 3.8 mΩ/Ω + 0.6R Fluke 5520A/SC1100 CMCs shown are based on 4-wire compensation only; for 2-wire & 2-wire compensation add 5 µV per ampere stimulus current (R floor = E/I) IET HRRS-B-6-1M- 5kV decade resistor Capacitance3 – Generate (0.19 to 0.3999) nF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099 99) µF (1.1 to 3.299 99) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF 0.66 % + 10 pF 0.63 % + 10 pF 0.64 % + 10 pF 0.28 % + 10 pF 0.27 % + 0.1 nF 0.23 % + 0.1 nF 0.29 % + 0.3 nF 0.25 % + 1.0 nF 0.21 % + 3.0 nF 0.22 % + 10 nF 0.34 % + 30 nF 0.37 % + 0.1 µF Fluke 5520A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.14) 07/29/2025 Page 5 of 14 Parameter/Equipment Range CMC2, 6, 7 (±) Comments Capacitance3 – Generate (cont) (110 to 329.999) µF (0.33 to 1.099 99) mF 0.37 % + 0.3 µF 0.38 % + 1.0 µF Fluke 5520A Electrical Simulation of Thermocouples3 – Type E Type J Type K Type T Type S (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C 0.58 °C 0.19 °C 0.17 °C 0.19 °C 0.25 °C 0.32 °C 0.32 °C 0.18 °C 0.21 °C 0.28 °C 0.39 °C 0.22 °C 0.19 °C 0.31 °C 0.47 °C 0.73 °C 0.29 °C 0.21 °C 0.19 °C 0.55 °C 0.42 °C 0.44 °C 0.54 °C Fluke 5520A Electrical Calibration of RTDs 3 – Pt 385, 100 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C 0.080 °C 0.080 °C 0.096 °C 0.11 °C Fluke 5520A
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.14) 07/29/2025 Page 6 of 14 Parameter/Equipment Range CMC2, 5, 6, 7 (±) Comments Electrical Calibration of RTDs3 – (cont) Pt 385, 100 Ω (300 to 400) °C (400 to 630) °C (630 to 800) °C 0.12 °C 0.14 °C 0.25 °C Fluke 5520A DC Current Generate – Clamp Meters (10 to 25) A (25 to 150) A (150 to 1025) A 0.62 % + 0.02 A 0.62 % + 0.14 A 0.62 % + 0.5 A Fluke 5520A, Fluke 5500A coil Oscilloscope3 – DC Signal 50 Ω 1 MΩ Square Wave 50 Ω 1 MΩ Leveled Sine Wave 5 mV to 5 V 5 mV to 2 V Time Markers 50 Ω Edge Transition 10 Hz to 2 MHz rate 10 Hz to 2 MHz rate 10 Hz to 1 MHz rate Pulse Width 1 mV to 200 V 1 mV to 50 V 1 mV pk-pk to 200 Vpk-pk 40 µVpk-pk to 1 mVpk-pk 50 kHz to 10 MHz 0.1 Hz to 300 MHz (>300 to 550) MHz (>0.55 to 3) GHz (>3 to 6.4) GHz 9.0091 ns to <83 µs >83 µs to 55 s 500 ps 150 ps 70 ps (1 to 100) ns 0.06 % + 25 μV 0.06 % + 25 µV 0.37 % + 10 µV 0.28 % + 10 µV 1.3 % 1.9 % 2.2 % 2.4 % 2.8 % 0.42 µs/s 2.4 µs/s 33 ps 14 ps 8.0 ps 4.1 % + 200 ps Fluke 9500B w/ 9530 & 9560 active head
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.14) 07/29/2025 Page 7 of 14 Parameter/Range Frequency CMC2, 6, 7 (±) Comments AC Voltage3 – Measure (1 to 10) mV (10 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz 0.036 % + 3.6 µV 0.028 % + 2.3 µV 0.036 % + 2.3 µV 0.11 % + 2.3 µV 0.50 % + 2.3 µV 4.0 % + 2.8 μV 89 µV/V + 4.0 µV 89 µV/V + 2.0 µV 0.015 % + 2.0 µV 0.035 % + 2.0 µV 0.082 % + 2.0 µV 0.30 % + 10 µV 1.0 % + 10 µV 77 µV/V + 40 µV 77 µV/V + 20 µV 0.014 % + 20 µV 0.03 % + 20 µV 0.8 mV/V + 20 µV 3.0 mV/V + 100 µV 10 mV/V + 100 µV 78 µV/V + 400 µV 78 µV/V + 200 µV 0.14 mV/V + 200 µV 0.3 mV/V + 200 µV 0.8 mV/V + 200 µV 3.0 mV/V + 1.0 mV 10 mV/V + 1.0 mV 0.2 mV/V + 4.0 mV 0.2 mV/V + 2.0 mV 0.2 mV/V + 2.0 mV 0.36 mV/V + 2.0 mV 1.2 mV/V + 2.0 mV 4.0 mV/V + 10 mV 15 mV/V + 10 mV HP 3458A opt-2
8--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.14) 07/29/2025 Page 8 of 14 Parameter/Range Frequency CMC2, 6, 7 (±) Comments AC Voltage3 – Measure (cont) (100 to 700) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.4 mV/V + 40 mV 0.4 mV/V + 20 mV 0.6 mV/V + 20 mV 1.2 mV/V + 20 mV 3.0 mV/V + 20 mV HP 3458A opt-2 AC Voltage3 – Generate (0 to 2.2) mV (>2.2 to 22) mV (>22 to 220) mV (10 to 20) Hz (>20 to 40) Hz (>0.040 to 20) kHz (>20 to 50) kHz (>50 to 100) kHz (>100 to 300) kHz (>300 to 500) kHz (>0.5 to 1) MHz (10 to 20) Hz (>20 to 40) Hz (>0.040 to 20) kHz (>20 to 50) kHz (>50 to 100) kHz (>100 to 300) kHz (>300 to 500) kHz (>0.5 to 1) MHz (10 to 20) Hz (>20 to 40) Hz (>0.040 to 20) kHz (>20 to 50) kHz (>50 to 100) kHz (>100 to 300) kHz (>300 to 500) kHz (>0.5 to 1) MHz 0.22 % + 4.0 µV 0.18 % + 4.0 µV 0.18 % + 4.0 µV 0.29 % + 4.0 µV 0.39 % + 5.0 µV 0.69 % + 10 µV 1.0 % + 20 µV 1.2 % + 20 µV 0.048 % + 4 µV 0.030 % + 4 µV 0.030 % + 4 µV 0.054 % + 4 µV 0.088 % + 5 µV 0.19 % + 10 µV 0.24 % + 20 µV 0.43 % + 20 µV 0.029 % + 12 µV 0.018 % + 7 µV 0.011 % + 7 µV 0.025 % + 7 µV 0.056 % + 17 µV 0.10 % + 20 µV 0.16 % + 25 µV 0.32 % + 45 µV Fluke 5720 series II
100 to 700 V
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.14) 07/29/2025 Page 9 of 14 Parameter/Range Frequency CMC2, 6, 7 (±) Comments AC Voltage3 – Generate (cont) (>0.22 to 2.2) V (>2.2 to 22) V (>22 to 220) V (>220 to 1020) V (220 to 750) V (750 to 1100) V (10 to 20) Hz (>20 to 40) Hz (>0.040 to 20) kHz (>20 to 50) kHz (>50 to 100) kHz (>100 to 300) kHz (>300 to 500) kHz (>0.5 to 1) MHz (10 to 20) Hz (>20 to 40) Hz (>0.040 to 20) kHz (>20 to 50) kHz (>50 to 100) kHz (>100 to 300) kHz (>300 to 500) kHz (>0.5 to 1) MHz (10 to 20) Hz (>20 to 40) Hz (>0.040 to 20) kHz (>20 to 50) kHz (>50 to 100) kHz (>100 to 300) kHz (>300 to 500) kHz (>0.5 to 1) MHz (15 to 50) Hz (>0.05 to 1) kHz (30 to 50) kHz (50 to 100) kHz 40 Hz to 1kHz (1 to 20) kHz (20 to 30) kHz 0.026 % + 40 µV 0.0099 % + 15 µV 0.0062 % + 8 µV 0.011 % + 10 µV 0.016 % + 30 µV 0.052 % + 80 µV 0.11 % + 200 µV 0.23 % + 300 µV 0.027 % + 400 µV 0.010 % + 150 µV 0.0066 % + 50 µV 0.011 % + 100 µV 0.016 % + 200 µV 0.044 % + 600 µV 0.12 % + 2.0 mV 0.24 % + 3.2 mV 0.027 % + 4.0 mV 0.011 % + 1.5 mV 0.0079 % + 0.6 mV 0.014 % + 1.0 mV 0.022 % + 2.5 mV 0.094 % + 16 mV 0.45 % + 40 mV 0.82 % + 80 mV 0.030 % + 16 mV 0.0080 % + 3.5 mV 0.24 % + 11 mV 0.33 % + 45 mV 0.011 % + 4 mV 0.018 % + 6 mV 0.060 % + 11 mV Fluke 5720 series II Fluke 5720 Series II, 5725A
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.14) 07/29/2025 Page 10 of 14 Parameter/Range Frequency CMC2, 6, 7 (±) Comments AC Current3 – Measure (5 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (45 to 1000) Hz (45 to 100) Hz (0.1 to 5) kHz (45 to 100) Hz (0.1 to 5) kHz (45 to 100) Hz (0.1 to 5) kHz (45 to 100) Hz (0.1 to 5) kHz 0.061 % + 30 nA 0.062 % + 200 nA 0.034 % + 200 nA 0.062 % + 2 µA 0.034 % + 2 µA 0.062 % + 20 µA 0.034 % + 20 µA 0.085 % + 200 µA 0.1 % + 200 µA HP 3458A opt-2 AC Current3 – Generate (0 to 220) µA (>0.22 to 2.2) mA (>2.2 to 22) mA (>22 to 220) mA (10 to 20) Hz (>20 to 40) Hz (>0.04 to 1) kHz (>1 to 5) kHz (>5 to 10) kHz (10 to 20) Hz (>20 to 40) Hz (>0.04 to 1) kHz (>1 to 5) kHz (>5 to 10) kHz (10 to 20) Hz (>20 to 40) Hz (>0.04 to 1) kHz (>1 to 5) kHz (>5 to 10) kHz (10 to 20) Hz (>20 to 40) Hz (>0.04 to 1) kHz (>1 to 5) kHz (>5 to 10) kHz 0.025 % + 16 nA 0.016 % + 10 nA 0.013 % + 8.0 nA 0.028 % + 12 µA 0.11 % + 65 µA 0.025 % + 40 nA 0.017 % + 35 nA 0.013 % + 35 nA 0.020 % + 110 nA 0.11 + 650 nA 0.027 % + 400 nA 0.018 % + 350 nA 0.014 % + 350 nA 0.021 % + 550 nA 0.11 % + 5.0 µA 0.027 % + 4.0 µA 0.018 % + 3.5 µA 0.014 % + 2.5 µA 0.021 % + 3.5 µA 0.11 % + 10 µA Fluke 5720A series II
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.14) 07/29/2025 Page 11 of 14 Parameter/Range Frequency CMC2, 5, 6, 7 (±) Comments AC Current3 – Generate (cont) (>0.22 to 2.2) A (>2.2 to 11) A (11 to 20) A (0.02 to 1) kHz (>1 to 5) kHz (>5 to 10) kHz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 45 Hz to 1 kHz (>1 to 5) kHz 0.027 % + 35 µA 0.046 % + 80 µA 0.7 % + 160 µA 0.047 % + 0.17 mA 0.095 % + 0.38 mA 0.36 % + 0.75 mA 0.15 % + 5.0 mA 3.0 % + 5.0 mA Fluke 5720A series II Fluke 5720A Series II, 5725A Fluke 5520A/SC1100 AC Current Generate – Clamp Meters – (10 to 25) A (25 to 150) A (150 to 1025) A (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 0.71 % + 0.03 A 1.3 % + 0.03 A 0.73 % + 0.25 A 1.7 % + 0.25 A 0.72 % + 0.9 A 1.6 % + 0.9 A Fluke 5520A, Fluke 5500A coil AC Power – Generate PF = 1 (0.01 to 0.1) W (0.1 to 890) W (0.89 to 3) kW (3 to 11) kW (11 to 20.4) kW 45 Hz to 1 kHz 45 Hz to 1 kHz 45 Hz to 1 kHz 45 Hz to 1 kHz 45 Hz to 1 kHz 0.22 % 0.18 % 0.19 % 0.26 % 0.27 % Fluke 5520A
12--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.14) 07/29/2025 Page 12 of 14 III. Mechanical Parameter/Equipment Range CMC2, 5, 9 (±) Comments Pressure Measuring Equipment – Gauges, Indicators & Transducers3 Pneumatic Hydraulic (2 to 50) in WC (2 to 5) psi (5 to 30) psi (30 to 100) psi (10 to 10 000) psi 0.14 % full scale 0.08 % full scale 0.03 % full scale 0.03 % full scale 0.027 % Pressure calibrator & modules, DMM Dead weight tester Atmospheric Pressure (Vacuum) Measuring Equipment3 – Indicators & Transducers (0 to 26.5) in·Hg 0.06 % full scale Pressure calibrator & modules, DMM Force – Measuring Equipment, Tension & Compression (0 to 1000) gf (0 to 2) lbf (2 to 20) lbf (20 to 110) lbf 2.3 mgf 0.04 lbf 0.05 lbf 0.05 lbf Dead weight method Torque Wrenches – Measuring Equipment (10 to 100) lbf·in 100 lbf·in to 50 lbf·ft (50 to 1000) lbf·ft 0.21 % 0.18 % 0.19 % AKO Torque calibrator w/ torque transducers Torque Watches & Screwdrivers – Measuring Equipment (0.5 to 215) ozf∙in (2.5 to 25) lbf∙in (10 to 100) ozf∙in 0.39 % 0.21 % 0.21 % Waters 6500 TS calibrator w/ weights & wheels Torque transducers
0 to 1000 lbf·ft
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.14) 07/29/2025 Page 13 of 14 IV. Thermodynamics4 Parameter/Equipment Range CMC2, 9 (±) Comments Temperature – Measuring Equipment (-20 to 140) °C (140 to 350) °C 0.084 °C 0.14 °C Precision oil bath, dry block calibrator or environmental chamber, electronic ice point comparison w/ PRT Temperature – Measure3 (-196 to 420) °C 0.068 °C Hart 1502A w/ Hart 5615 PRT Relative Humidity – Measure3 (10 to 50) % RH (50 to 90) % RH (90 to 95) % RH 1.2 % RH 1.4 % RH 2.4 % RH Vaisala HMI 41 w/ HMP 46 probe Relative Humidity – Measuring Equipment (10 to 50) % RH (50 to 90) % RH 1.2 % RH 1.4 % RH General Eastern M1 dew point meter V. Time & Frequency Parameter/Equipment Range CMC2, 5, 9 (±) Comments Frequency – Measuring Equipment3 10 MHz Reference DC to 80 MHz 10 MHz to 26.5 GHz 0.01 nHz/Hz 0.01 nHz/Hz + 0.6R 0.01 nHz/Hz + 0.6R HP 58503A GPS reference monitor Agilent 33250A HP 8340B Frequency – Measure3 0.1 Hz to 225 MHz 100 MHz to 26.5 GHz 0.01 nHz/Hz + 0.6R 0.01 nHz/Hz + 0.6R Agilent 53131A HP 5351B Stopwatches & Timers (0 to 19.99) s/day 0.037 s/day Helmut Klein 4500 Timometer Tachometer – Optical (60 to 200 000) RPM 0.0017 % + 0.6R HP 3325B ____________________________________________
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.14) 07/29/2025 Page 14 of 14 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 Type of devices calibrated under the Thermodynamic parameters: Liquid in Glass Thermometers, Bi - metallic Thermometers, Thermometry Systems, Thermocouple Probes and Wires, Temperature Indicators, Temperature Transmitters, Relative Humidity Indicators, Rela tive Humidity Transmitters, Ovens, Chambers, Temperature Controllers, Temperature Measuring Equipment, Thermometry System Calibrators and Temperature Meter and Probe Combinations. 5 In the statement of CMC, R is the numerical value of the resolution of the device and L is the length in inches. In the statement of CMC, the value is defined as the percentage of reading. 6 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 7 Floor noise is additive to all readings. 8 This scope meets A2LA’s P112 Flexible Scope Policy. 9 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
15ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

6537 Cecilia Circle, Bloomington, MN, 55439, US

44.83224, -93.32049

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.