Registers refreshed 2026-11-20.See refresh dates
United States

Microbac Laboratories, Inc.

105 Carpenter Drive, 20164, Sterling, VA, United States

Visit website
A2LA 3376.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
22
A2LA certificate
1
Sites in our directory
3
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 22 standard numbers and the 5 official names we hold. When no standard matches, it searches the method text of every scope line.

EN9
EN 1040
EN 1275
EN 13610
EN 13624
EN 13697
EN 13727
EN 14476
EN 14675
EN 16777
ASTM6
ASTM E1052
ASTM E1053
ASTM E1054
ASTM E1115
ASTM E1153
ASTM E1173
ISO5
ISO 18184Textiles - Determination of antiviral activity of textile products
ISO 21702Measurement of antiviral activity on plastics and other non-porous surfaces
ISO 22442-3Medical devices utilizing animal tissues and their derivatives - Part 3: Validation of the elimination and/or inactivation of viruses and transmissible spongiform encephalopathy (TSE) agents
ISO 23409Male condoms - Requirements and test methods for condoms made from synthetic materials
ISO 25841Female condoms - Requirements and test methods
Other standards2
AATCC 100
USP 1072

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Active

3376.01

The scope document we hold says it is valid until 2027-01-31.

View scope

Accredited scope, certificate 3376.01

LineMethodMatrixRange
1ICH Q5A Sept. 1999; FDA-PTC mAb for Human Use; EMEA-CHMP-BWP 398498 (July 2008); ISO 22442-3 (2007) LU Reference; AATCC100; JIS L1902; EN 1040:2005; EN 1275:2005; ISO 23409 Annex G; ISO 25841 Annex G; FDA CDRH Guidance, June 29, 1995; Chapter 1072 of the US Pharmacopeia; FDA (1993), “Guide to Inspections Validation of Cleaning Processes” <USP 1072>suspensions, and hard and soft surfaces-
2ASTM E1054; ASTM E1153; ASTM 1174; ISO 21702; CLSI- M07; ASTM E1173; I.S. EN 13697:2015+A1(2019) E; EN 16777; EN 14675; PAS 2424; BS EN 13727:2012+A2:2015; BS EN 13624:2013; EN 13610; ASTM E1115; ISO 18184; FDA CDRH “Guidance for Manufacturers Seeking Marketing Clearance of Ear, Nose, and Throat Endoscope Sheaths Used as Protective Barriers (March 12, 2000)”--
3ICH Q5A Sept 1999; FDA-PTC mAb for Human Use; EMEA-CHMP-BWP 398498 (July 2008); ISO 22442-3 (2007); ASTM E1053; EN 14476; ASTM E1052--
4

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Biological Scope of Accreditation. Accredited Laboratory A2LA has accredited MICROBAC LABORATORIES, INC. Sterling, VA for technical competence in the field of Biological Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 21st day of January 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 3376.01 Valid to January 31, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

105 Carpenter Drive, Sterling, VA, 20164, US

39.00175, -77.40333

Open in Maps

Other Locations

2 other sites in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.