IMP Electronic Systems
3101 Hammonds Plains Road, B3Z 1H7, Hammonds Plains, NS, Canada
Visit websiteNo active accreditation in the register.
Scope as published by A2LA
6 lines
ISO/IEC 17025
Withdrawn4741.01
Accredited scope, certificate 4741.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 24 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4741.01) 09/26/2024 Page 2 of 5
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
DC Voltage – Generate
1 mV to 1 V
(1 to 10) V
(10 to 100) V
100 V to 1 kV
(0.002 53 + 6.7 V) µV
(4.6 + 2.1 V) µV
(-16 + 4.2 V) µV
(-160 + 5.6 V) µV
Fluke multi product
calibrator 5522A
DC Current – Generate
(0 to 10) mA
(10 to 100) mA
100 mA to 1 A
(1 to 20) A
(0.059 + 12. A) µA
(0.12 + 5.8 A) µA
(-11 + 120 A) µA
(-26 + 150 A) µA
Fluke multi product
calibrator 5522A
DC Resistance (4 Wire)
– Generate
(0.01 to 100) Ω
100 Ω to 1 kΩ
(1 to 100) kΩ
100 kΩ to 1 MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(.64 + 0.011 R) mΩ
(0.84 + 0.01 56 R) mΩ
(0.67 + 0.01 79 R) mΩ
(180 + 0.01 02 R) mΩ
(-7550 + 0.015 R) mΩ
(-1067 + 0.000 12 R) Ω
Fluke multi product
calibrator 5522A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4741.01) 09/26/2024 Page 3 of 5
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Voltage – Generate
(1.0 to <33) mV
(33 to <330) mV
(0.33 to <3.3) V
(3.3 to <33) V
(33 to <330) V
(330 to 1020) V
10 Hz to 50 kHz
(50 to 500) kHz
10 Hz to 50 kHz
(50 to 500) kHz
10 Hz to 50 kHz
(50 to 500) kHz
10 Hz to 50 kHz
(50 to 100) kHz
110 Hz to 50 kHz
(50 to 100) kHz
45 Hz to 10 kHz
(3.3 + 0.18 V) µV
(3.04 + 0.457V) µV
(0.89 + 0.12 V) µV
(9.4 + 0.12 V) µV
(616 + 97 V) µV
(1150 - 170 V) µV
(-140 + 138 V) µV
(-22 + 60 V) µV
(-2380 + 110 V) µV
(-7890 + 290) µV
(2565 + 38 V) µV
Fluke multi product
calibrator 5522A
AC Current – Generate
1A
10 Hz to 10 kHz
(119 + 0.098 A) µA
Fluke multi product
calibrator 5522A
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
Capacitance – Generate
220 pF to 11 nF
Up to 3.3 μF
(0.00276 + 0.00064 C)
nF
(-0.00085 + 0.0039 C)
µF
Fluke multi product
calibrator 5522A
Electrical Simulation of
Thermocouples –
Type K
(-200 to 1372) °C
(0.289 + 0.00059 Tp)
°C
Fluke multi product
calibrator 5522A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4741.01) 09/26/2024 Page 4 of 5
III. Mechanical
Parameter/Equipment
Range
CMC2, 3, 4 (±)
Comments
Torque – Measuring
Equipment
(1 to 10) ozf·in
(10 to 50) ozf·in
(5 to 50) lbf·in
(25 to 250) lbf·in
(15 to 150) lbf∙ft
(100 to 2000) lbf∙ft
0.3 in-oz
(0.025 + 0.0275 T) in-oz
(0.8 - 0.0018 T) in-lbs
(1.09 + 0.044 T) in-lbs
(0.56 + 0.0036 T) ft-lbs
(0.79 + 0.0033 T) ft-lbs
Advanced witness systems
display, loader, &
transducers
Tensiometer (Banding
Tools)
(40 to 200) lb
(0.6 + 0.004 F) lbs
EFG-Microprocessor force
gauge
IV. Time & Frequency
Parameter/Equipment
Range
CMC2, 3, 4 (±)
Comments
Frequency – Measuring
Equipment
10 Hz to 2 MHz
(-0.012 + 0.002 Fr) Hz
Fluke multi product
calibrator 5522A
__________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4741.01) 09/26/2024 Page 5 of 5
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches.
V is the numerical value for voltage in volts. A is the numerical value for current in amps. R is the
numerical value for resistance in ohms. C is the numerical value for capacitance in farads. Tp is the
numerical value for temperature in degrees Celsius. T is the numerical value for torque as specified by
the unit indicated in the table above. F is the numerical value for force in pounds. Fr is the numerical
value for frequency in hertz.
5 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent
or fraction of the reading plus a fixed floor specification.
6 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
IMP ELECTRONIC SYSTEMS
Hammond Plains, Nova Scotia, CANADA
for technical competence in the field of
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General
requirements for the competence of testing and calibration laboratories and R205 – Specific Requirements: Calibration Laboratory
Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the
operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 26th day of September 2024.
_______________________
Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 4741.01
Valid to March 31, 2026 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.