Quality Tech Services
132 Gralan Drive, 31008, Byron, GA, United States
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 2921.01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 3200 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2921.01) 03/04/2024 Page 2 of 3
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
Angular Displacement –
CNC, CMM,
Inclinometers and Levels3
(-10 to 10)°
[0.38 + (0.006A + 0.1 + 0.007F)]
arc seconds
[(0.02 % A) + 0.5 + 0.1M] µm/m
Laser systems, XL,
XM
w/ special optics
with measured
angular factor
(XL only)
Angle – Measure3
Up to 40 000
μm/m
3.4 μm/m (0.7 arc seconds)
Wyler electronic
levels, wireless
Rotational Positioning –
Rotary Encoders,
Inclinometers/Levels,
Rotary Indexes/Tables3
(-360 to 360)°
[2.2 + (0.006A + 0.1)] arc
seconds
[(0.02 % A) + 0.5 + 0.1M] µm/m
RX10, Ultradex
rotary calibrator,
wireless XR20-W
w/ special optics
with measured
angular factor
(XL only)
Circular Interpolation
Volume – CMMs, CNC
and Machine Tools3
(50 to 600) mm
[2.4 + (0.4 % V)] μm
QC20-W ball bar,
wireless
____________________________________________
1 This laboratory offers commercial calibration and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, S is displayed straightness reading in μin; F is distance traveled in feet; A is the
displayed angle in arc seconds; A is the angle measured in μradians; M is the linear measurement between
angular interferometer and reflection in meters; and V is the radial circularity variation reading in μm. | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2921.01) 03/04/2024 Page 3 of 3
5 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
6 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 4 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Yokogawa Corporation of AmericaNewnan, GA · ~126 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Technical Maintenance, Inc. - PEACHTREE CORNERSPeachtree Corners, GA · ~153 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Hottinger Bruel & KjaerDuluth, GA · ~154 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Applied Technical ServicesMarietta, GA · ~164 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Atlanta, GAAlpharetta, GA · ~166 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .