KSIGN (Guangdong) Testing Co.,
West Side of 1/F., Building C, Zone A, Fuyuan New Factory, Jiujiu Industrial Park, Minzhu, Shatou, Shajing, Bao'an District, Shenzhen, Guangdong, People's Republic of China, Shenzhen, Guangdong, China
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at KSIGN (Guangdong) Testing Co.,?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 5457.01Active
Certificates and scope
1ISO/IEC 17025
Active5457.01
The scope document we hold says it is valid until 2027-10-31.
Accredited scope, certificate 5457.01
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | electrical | ANSI C63.4:2014; ICES-Gen; ICES-001; ICES-003; ICES-005; CISPR 32 (excluding Annex H); EN 55032 (excluding Annex H); BS EN IEC 55032 (excluding Annex H); AS/NZS CISPR 32 (excluding Annex H); CISPR 11; EN 55011; BS EN IEC 55011; AS/NZS CISPR 11; CISPR 14-1; EN IEC 55014-1; AS/NZS CISPR 14-1; BS EN IEC 55014-1; CISPR 15; EN IEC 55015; BS EN IEC 55015; AS/NZS CISPR 15; VCCI V-3; VCCI V-32-1; GB 4343.1; GB/T 17743; GB 4824; GB/T 9254.1; IEC 61000-3-2; EN IEC 61000-3-2; GB/T 17625.1; AS/NZS 61000.3.2; BS EN IEC 61000-3-2; IEC 61000-3-3; EN 61000-3-3; BS EN 61000-3-3; GB/T 17625.2; AS/NZS 61000.3.3; IEC 61000-4-2; EN 61000-4-2; BS EN 61000-4-2; AS/NZS 61000.4.2; GB/T 17626.2 | unintentional and intentional radiators | to 40 GHz |
| 2 | - | - | - | - |
| 3 | electrical | EN IEC 55014-2; BS EN IEC 55014-2; EN IEC 61547; BS EN IEC 61547; BETS-7; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-4; ETSI EN 301 489-6; ETSI EN 301 489-9; ETSI EN 301 489-17; ETSI EN 301 489-19; ETSI EN301 489-27; ETSI EN 301 489-29; ETSI EN301 489-31; ETSI EN 301 489-34; ETSI EN301 489-35; ETSI EN 301 489-50; ETSI EN 301 489-53; Ordinance of MPT No.37, Article 2 Paragraph 1 Item 19; Item 19-2; Item 19-3; Item 19-3-2; Article 2 Paragraph 1 of Item 11‐3; Article 2 Paragraph 1 of Item 11‐4; Article 2 Paragraph 1 of Item 11‐7; Article 2 Paragraph 1 of Item 11‐8; Article 2 Paragraph 1 of Item 11‐19; Article 2 Paragraph 1 of Item 11‐21; Article 2 Paragraph 1 of Item 54; ANSI C63.10:2020; ANSI C63.26-2015; ANSI/TIA-603-E; RSS-GEN; RSS-130; RSS-132; RSS-133; RSS-139; RSS-195; RSS-199; RSS-210; RSS-215; RSS-216; RSS-247; RSS-310; ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 300 220-3-1; ETSI EN 300 220-3-2; ETSI EN 300 220-4; ETSI EN 300 328; ETSI EN 300 330; ETSI EN 300 422-1; ETSI EN 300 422-2; ETSI EN 300 422-3; ETSI EN 300 422-4; ETSI EN 300 440; ETSI EN 301 357; ETSI EN 301 511; ETSI EN 301 559; ETSI EN 301 893; ETSI EN 301 908-1; ETSI EN 301 908-2; ETSI EN 301 908-3; ETSI EN 301 908-11; ETSI EN 301 908-13; ETSI EN 301 908-14; ETSI EN 301 908-15; ETSI EN 302 195; ETSI EN 302 502; ETSI EN 302 537 | - | to 40 GHz |
| 4 | electrical | ETSI EN 303 340; ETSI EN 303 345-1; ETSI EN 303 372-1; ETSI EN 303 372-2; ETSI EN 303 413; ETSI EN 303 417; ETSI EN 303 609; ETSI EN 303 258; AS/NZS 4268; AS/CA S042.1; AS/ACIF S042.3; AS/CA S042.4; EN IEC 62311; BS EN IEC 62311; EN 62479; BS EN 62479; EN 50385; EN 50383; EN 50364; EN 50663; BS EN 50663; EN 50665; BS EN 50665; IEC 62493; EN 62493; IEC 62233; EN 62233; BS EN IEC 62233; AS/NZS 2772.2; Radiation Protection Series S-1 (Rev. 1); AS/NZS 62368.1; IEC 62368-1; EN 62368-1; ANSI/UL 62368-1 | - | - |
| 5 | electrical | 62368-1 | - | - |
| 6 | electrical | - | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Labs with overlapping accredited scope in China
- DEKRA Testing and Certification (Suzhou) Co.,Suzhou, Jiangsu ProvinceA2LAShares 2 accredited test methodsANSI C63.4:2014ETSI EN 303 413
- Shenzhen Morlab Communications TechnologyShenzhenA2LAShares 2 accredited test methodsANSI C63.4:2014ETSI EN 303 413
- CTC Laboratories, Inc.Shenzhen, GuangdongA2LAShares 1 accredited test methodANSI C63.4:2014
- CTSL Testing (Dongguan) Co.,DongguanA2LAShares 1 accredited test methodANSI C63.4:2014
- DEKRA TESTING SERVICES (ANHUI) CO.,Hefei, Anhui ProvinceA2LAShares 1 accredited test methodANSI C63.4:2014
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.