FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
China

KSIGN (Guangdong) Testing Co.,

West Side of 1/F., Building C, Zone A, Fuyuan New Factory, Jiujiu Industrial Park, Minzhu, Shatou, Shajing, Bao'an District, Shenzhen, Guangdong, People's Republic of China, Shenzhen, Guangdong, China

A2LA|5457.01ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
6
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at KSIGN (Guangdong) Testing Co.,?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
5457.01Active

Certificates and scope

1
A2LA

ISO/IEC 17025

Active

5457.01

The scope document we hold says it is valid until 2027-10-31.

View scope

Accredited scope, certificate 5457.01

LineDisciplineMethodMatrixRange
1electricalANSI C63.4:2014; ICES-Gen; ICES-001; ICES-003; ICES-005; CISPR 32 (excluding Annex H); EN 55032 (excluding Annex H); BS EN IEC 55032 (excluding Annex H); AS/NZS CISPR 32 (excluding Annex H); CISPR 11; EN 55011; BS EN IEC 55011; AS/NZS CISPR 11; CISPR 14-1; EN IEC 55014-1; AS/NZS CISPR 14-1; BS EN IEC 55014-1; CISPR 15; EN IEC 55015; BS EN IEC 55015; AS/NZS CISPR 15; VCCI V-3; VCCI V-32-1; GB 4343.1; GB/T 17743; GB 4824; GB/T 9254.1; IEC 61000-3-2; EN IEC 61000-3-2; GB/T 17625.1; AS/NZS 61000.3.2; BS EN IEC 61000-3-2; IEC 61000-3-3; EN 61000-3-3; BS EN 61000-3-3; GB/T 17625.2; AS/NZS 61000.3.3; IEC 61000-4-2; EN 61000-4-2; BS EN 61000-4-2; AS/NZS 61000.4.2; GB/T 17626.2unintentional and intentional radiatorsto 40 GHz
2----
3electricalEN IEC 55014-2; BS EN IEC 55014-2; EN IEC 61547; BS EN IEC 61547; BETS-7; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-4; ETSI EN 301 489-6; ETSI EN 301 489-9; ETSI EN 301 489-17; ETSI EN 301 489-19; ETSI EN301 489-27; ETSI EN 301 489-29; ETSI EN301 489-31; ETSI EN 301 489-34; ETSI EN301 489-35; ETSI EN 301 489-50; ETSI EN 301 489-53; Ordinance of MPT No.37, Article 2 Paragraph 1 Item 19; Item 19-2; Item 19-3; Item 19-3-2; Article 2 Paragraph 1 of Item 11‐3; Article 2 Paragraph 1 of Item 11‐4; Article 2 Paragraph 1 of Item 11‐7; Article 2 Paragraph 1 of Item 11‐8; Article 2 Paragraph 1 of Item 11‐19; Article 2 Paragraph 1 of Item 11‐21; Article 2 Paragraph 1 of Item 54; ANSI C63.10:2020; ANSI C63.26-2015; ANSI/TIA-603-E; RSS-GEN; RSS-130; RSS-132; RSS-133; RSS-139; RSS-195; RSS-199; RSS-210; RSS-215; RSS-216; RSS-247; RSS-310; ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 300 220-3-1; ETSI EN 300 220-3-2; ETSI EN 300 220-4; ETSI EN 300 328; ETSI EN 300 330; ETSI EN 300 422-1; ETSI EN 300 422-2; ETSI EN 300 422-3; ETSI EN 300 422-4; ETSI EN 300 440; ETSI EN 301 357; ETSI EN 301 511; ETSI EN 301 559; ETSI EN 301 893; ETSI EN 301 908-1; ETSI EN 301 908-2; ETSI EN 301 908-3; ETSI EN 301 908-11; ETSI EN 301 908-13; ETSI EN 301 908-14; ETSI EN 301 908-15; ETSI EN 302 195; ETSI EN 302 502; ETSI EN 302 537-to 40 GHz
4electricalETSI EN 303 340; ETSI EN 303 345-1; ETSI EN 303 372-1; ETSI EN 303 372-2; ETSI EN 303 413; ETSI EN 303 417; ETSI EN 303 609; ETSI EN 303 258; AS/NZS 4268; AS/CA S042.1; AS/ACIF S042.3; AS/CA S042.4; EN IEC 62311; BS EN IEC 62311; EN 62479; BS EN 62479; EN 50385; EN 50383; EN 50364; EN 50663; BS EN 50663; EN 50665; BS EN 50665; IEC 62493; EN 62493; IEC 62233; EN 62233; BS EN IEC 62233; AS/NZS 2772.2; Radiation Protection Series S-1 (Rev. 1); AS/NZS 62368.1; IEC 62368-1; EN 62368-1; ANSI/UL 62368-1--
5electrical62368-1--
6electrical---

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.