Registers refreshed 2026-11-20.See refresh dates
Italy

LABORATORIO 3 A SAS DI CERCHIARI MANUELE & C

Via Padre Giacobazzi 25/B, 41026, Pavullo nel Frignano, Italy

ACCREDIA 00484ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
17
ACCREDIA certificate
1
Site in our directory
1
ACCREDIA accredited scope

What this lab is accredited for

Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 17 standard numbers and the 14 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO14
ISO 4833-1Microbiology of the food chain - Horizontal method for the enumeration of microorganisms - Part 1: Colony count at 30 °C by the pour plate technique
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 6579-1Microbiology of the food chain - Horizontal method for the detection, enumeration and serotyping of Salmonella - Part 1: Detection of Salmonella spp.
ISO 6888-2Microbiology of the food chain - Horizontal method for the enumeration of coagulase-positive staphylococci (Staphylococcus aureus and other species) - Part 2: Method using rabbit plasma fibrinogen agar medium
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 9622Milk and liquid milk products - Guidelines for the application of mid-infrared spectrometry
ISO 11290-1Microbiology of the food chain - Horizontal method for the detection and enumeration of Listeria monocytogenes and of Listeria spp. - Part 1: Detection method
ISO 11731Water quality - Enumeration of Legionella

Certificate says EN ISO 11731 2019-03 UBA Empfehlung 18. Probably the same standard; not checked against the EN document.

ISO 13366-2Milk - Enumeration of somatic cells - Part 2: Guidance on the operation of fluoro-opto-electronic counters
ISO 14189Water quality - Enumeration of Clostridium perfringens - Method using membrane filtration
ISO 16649-2Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of beta-glucuronidase-positive Escherichia coli - Part 2: Colony-count technique at 44 degrees C using 5-bromo-4-chloro-3-indolyl beta-D-glucuronide
ISO 18593Microbiology of the food chain - Horizontal methods for surface sampling
ISO 22196Measurement of antibacterial activity on plastics and other non-porous surfaces
Other standards3
NF V08-061
V08-050
V08-054

Read from the scope as published by ACCREDIA. Register refreshed 2026-11-20.

Scope as published by ACCREDIA

2 lines
ACCREDIA

ISO/IEC 17025

Active

00484

View scope

Accredited scope, certificate 00484

LineMethodMatrixRange
1UNI CEI EN ISO/IEC 17025:2018; UNI EN ISO 9308-1:2017; UNI EN ISO 14189:2016; UNI EN ISO 7899-2:2003; UNI EN ISO 11731:2017; UNI EN ISO 6222:2001; NF V08-061:2009; NF V08-050:2009; NF V08-054:2009; UNI ISO 16649-2:2010; UNI EN ISO 6888-2:2023; ISO 4833-1:2013/Amd 1:2022; UNI EN ISO 4833-1:2022; UNI EN ISO 6579-1:2020; AFNOR NEO 35/06-07/16; UNI EN ISO 11290-1:2017; AOAC Ridascreen Gliadin n 120601 2006; IS BSC rev3 2023; ISO 9622:2013 (IDF 141:2013); ISO 13366-2:2006 (IDF 148-2:2006); AOAC DSM Delvotest SP-NT Visual n 011102 2011; ISO 22196:2011Drinking waterSee scope document
2ISO 18593:2018; NF V08-054:2009Samples from surface sampling of food industry environment-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Via Padre Giacobazzi 25/B, Pavullo nel Frignano, 41026, IT

44.33969, 10.83411

Open in Maps

Accreditation data refreshed from the ACCREDIA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.