Registers refreshed 2026-11-08.See refresh dates
France

MAPE - MÉTIER ENVIRONNEMENT

ZI DE L'ALOUETTE 260 RUE BLAISE PASCAL, 62800, LIEVIN, France

COFRAC 1-6837ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
31
COFRAC certificate
1
Sites in our directory
2
COFRAC accredited scope

What this lab is accredited for

Our reading of the COFRAC scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 31 standard numbers and the 16 official names we hold. When no standard matches, it searches the method text of every scope line.

EN13
EN 1911-1
EN 1948-1Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Part 1: Sampling of PCDDs/PCDFs
EN 12619Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
EN 13211Air quality - Stationary source emissions - Manual method of determination of the concentration of total mercury
EN 13284-1Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method
EN 14181Stationary source emissions - Quality assurance of automated measuring systems
EN 14385Stationary source emissions - Determination of the total emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl and V
EN 14789Stationary source emissions - Determination of volume concentration of oxygen - Standard reference method: Paramagnetism
EN 14790Stationary source emissions - Determination of the water vapour in ducts - Standard reference method
EN 14791Stationary source emissions - Determination of mass concentration of sulphur oxides - Standard reference method
EN 14792Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: Chemiluminescence
EN 15058Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry
EN 15259Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report
NF7
NF X43-264
NF X43-269
NF X43-317
NF X43-329
NF X43-551
NF X44-052
NF X 31-615
XP5
XP X43-051
XP X43-126
XP X43-132
XP X43-136
XP X43-554
ISO4
ISO 10523Water quality - Determination of pH
ISO 10780Stationary source emissions - Measurement of velocity and volume flowrate of gas streams in ducts
ISO 16911-1Stationary source emissions - Manual and automatic determination of velocity and volume flow rate in ducts - Part 1: Manual reference method
ISO 21877Stationary source emissions— Determination of the mass concentration of ammonia - Manual method
Other standards2
FD T 90-523-2
FD X43-140

Read from the COFRAC scope document we downloaded on 2026-11-06. Register refreshed 2026-11-06.

Scope as published by COFRAC

10 lines
COFRAC

ISO/IEC 17025

Active

1-6837

The scope document we hold says it is valid until 2031-06-30.

View scope

Location

ZI DE L'ALOUETTE 260 RUE BLAISE PASCAL, LIEVIN, 62800, FR

50.42450, 2.77380

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the COFRAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.