Industronics Service Company
489 Sullivan Ave, 06074, South Windsor, CT, United States
Visit website- Scope lines
- 11
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 11 scope lines.
A2LA certificate 1619.01 · 11 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 1000 V |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1619.01) 09/22/2025 Page 2 of 10
Parameter/Equipment
Range CMC2, 5 (±) Comments
DC Current3 –
Generate
Measure
Up to 330 µA
330 µA to 3.3 mA
(3.3 to 33) mA
(33 to 330) mA
330 mA to 1.1 A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
(20.5 to 1000) A
(0 to 30) mA
120 μA/A + 0.014 μA
67 μA/A + 0.039 μA
72 μA/A + 0.16 μA
62 μA/A + 2.0 μA
210 μA/A + 4.0 μA
250 μA/A + 73 μA
490 μA/A + 480 μA
620 μA/A + 2.1 mA
6300 μA/A + 0.16 A
55 μA/A + 0.99 μA
Fluke 5520A
w/ coil
Fluke 8508A
Electrical Calibration of
RTD Indicating Devices3 –
Generate (Standard
Sourcing, Unit Under Test
Measuring)
Pt 385, 100 Ω
Pt 385, 200 Ω
Pt 385, 500 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
0.04 °C
0.042 °C
0.057 °C
0.076 °C
0.084 °C
0.11 °C
0.19 °C
0.032 °C
0.035 °C
0.038 °C
0.058 °C
0.11 °C
0.11 °C
0.13 °C
0.14 °C
0.036 °C
0.046 °C
0.047 °C
0.064 °C
0.076 °C
0.087 °C
0.12 °C
0.13 °C
Fluke 5520A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1619.01) 09/22/2025 Page 3 of 10
Parameter/Equipment
Range CMC2 (±) Comments
Electrical Calibration of
RTD Indicating Devices3 –
Generate (Standard Sourcing,
Unit Under Test Measuring)
(cont)
Pt 385, 1000 Ω
Pt 3916, 100 Ω
Pt 3926, 100 Ω
Pt Ni 385, 120 Ω (Ni 120)
Cu 427, 10 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(-100 to 260) °C
0.028 °C
0.029 °C
0.046 °C
0.063 °C
0.072 °C
0.091 °C
0.11 °C
0.21 °C
0.20 °C
0.032 °C
0.041 °C
0.048 °C
0.059 °C
0.066 °C
0.077 °C
0.086 °C
0.19 °C
0.040 °C
0.040 °C
0.057 °C
0.074 °C
0.084 °C
0.11 °C
0.063 °C
0.065 °C
0.11 °C
0.28 °C
Fluke 5520A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1619.01) 09/22/2025 Page 4 of 10
Parameter/Equipment
Range CMC2 (±) Comments
Electrical Calibration of
RTD Indicating Devices3 –
Measure (Standard Measuring,
Unit Under Test Sourcing)
Pt 385, 100 Ω
Pt 385, 200 Ω
Pt 385, 500 Ω
Pt 385, 1000 Ω
Pt 3916, 100 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
0.078 °C
0.08 °C
0.087 °C
0.09 °C
0.097 °C
0.11 °C
0.13 °C
0.098 °C
0.10 °C
0.11 °C
0.11 °C
0.12 °C
0.12 °C
0.13 °C
0.15 °C
0.08 °C
0.081 °C
0.083 °C
0.088 °C
0.096 °C
0.11 °C
0.11 °C
0.11 °C
0.077 °C
0.077 °C
0.081 °C
0.086 °C
0.086 °C
0.087 °C
0.092 °C
0.093 °C
0.076 °C
0.078 °C
0.079 °C
0.085 °C
0.093 °C
0.093 °C
0.098 °C
0.11 °C
0.11 °C
Fluke 7526A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1619.01) 09/22/2025 Page 5 of 10
Parameter/Equipment
Range CMC2 (±) Comments
Electrical Calibration of RTD
Indicating Devices3 – Measure
(Standard Measuring, Unit Under
Test Sourcing) (cont)
Pt 3926, 100 Ω
PtNi 385, 120 Ω (Ni 120)
Cu 427, 10 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(-100 to 260) °C
0.079 °C
0.079 °C
0.084 °C
0.087 °C
0.092 °C
0.11 °C
0.077 °C
0.078 °C
0.078 °C
0.19 °C
Fluke 7526A
Electrical Calibration of
Thermocouple Indicating Devices3
– Measure (Standard Measuring,
Unit Under Test Sourcing)
Type B
Type C
Type E
Type J
(600 to 800) °C
(800 to 1000) °C
(1000 to 1550) °C
(1550 to 1820) °C
(0 to 150) °C
(150 to 650) °C
(650 to 1000) °C
(1000 to 1800) °C
(1800 to 2316) °C
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
0.46 °C
0.40 °C
0.38 °C
0.39 °C
0.37 °C
0.35 °C
0.38 °C
0.49 °C
0.72 °C
0.53 °C
0.32 °C
0.31 °C
0.31 °C
0.33 °C
0.62 °C
0.32 °C
0.31 °C
0.32 °C
0.34 °C
Fluke 5520A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1619.01) 09/22/2025 Page 6 of 10
Parameter/Equipment
Range CMC2 (±) Comments
Electrical Calibration of
Thermocouple Indicating Devices3
– Measure (Standard Measuring,
Unit Under Test Sourcing) (cont)
Type K
Type N
Type R
Type S
Type T
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.39 °C
0.32 °C
0.32 °C
0.35 °C
0.43 °C
0.43 °C
0.34 °C
0.33 °C
0.32 °C
0.36 °C
0.54 °C
0.42 °C
0.41 °C
0.43 °C
0.48 °C
0.42 °C
0.42 °C
0.47 °C
0.78 °C
0.36 °C
0.33 °C
0.32 °C
Fluke 5520A
Electrical Calibration of
Thermocouple Indicating Devices3
– Generate (Standard Sourcing,
Unit Under Test Measuring)
Type B
Type C
(600 to 800) °C
(800 to 1000) °C
(1000 to 1550) °C
(1550 to 1820) °C
(0 to 150) °C
(150 to 650) °C
(650 to 1000) °C
(1000 to 1800) °C
(1800 to 2316) °C
0.53 °C
0.40 °C
0.34 °C
0.33 °C
0.30 °C
0.25 °C
0.28 °C
0.45 °C
0.72 °C
Fluke 5520A | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1619.01) 09/22/2025 Page 7 of 10
Parameter/Equipment
Range CMC2 (±) Comments
Electrical Calibration of
Thermocouple Indicating Devices3
– Generate (Standard Sourcing,
Unit Under Test Measuring) (cont)
Type E
Type J
Type K
Type N
Type R
Type S
Type T
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.60 °C
0.14 °C
0.13 °C
0.13 °C
0.20 °C
0.32 °C
0.14 °C
0.16 °C
0.17 °C
0.19 °C
0.34 °C
0.22 °C
0.19 °C
0.25 °C
0.33 °C
0.40 °C
0.21 °C
0.18 °C
0.18 °C
0.24 °C
0.63 °C
0.38 °C
0.35 °C
0.37 °C
0.63 °C
0.40 °C
0.38 °C
0.43 °C
0.75 °C
0.27 °C
0.20 °C
0.17 °C
Fluke 5520A | ||
| 8 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1619.01) 09/22/2025 Page 8 of 10
III. Mechanical
Parameter/Equipment
Range CMC2, 4, 7 (±) Comments
Pressure3 – Measure &
Measuring Equipment
Pneumatic
Hydraulic
Up to 1 psig
(1 to 15) psig
(15 to 100) psig
(100 to 1500) psig
(1500 to 15 000) psig
0.032 psi
0.062 psi
0.12 psi
4.2 psi
12 psi
Fluke 700RG pressure
modules
Additel ADT672-05-
GP 15K-PSI-N2
Vacuum3 – Measure &
Measuring Equipment
Atmosphere to 10-2 torr
(10-2 to 10-6) torr
23 %
23 %
Inficon/Leybold
IV. Thermodynamics
Parameter/Equipment
Range CMC2, 7 (±) Comments
Dew Point – Measuring
Equipment
(-112 to 32) °F
(32 to 70) °F
1.1 °F
0.85 °F
Chilled mirror dew
point
Relative Humidity –
Measuring Equipment
(0 to 100%) RH
1.0 % RH
Chilled mirror dew
point
Temperature – Measure
& Measuring Equipment
Type B
Type E
Type J
Type K
(572 to 1112) °F
(1112 to 2012) °F
(2012 to 2192) °F
(2192 to 2200) °F
(32 to 572) °F
(572 to 1292) °F
(32 to 1832) °F
(32 to 1832) °F
(1832 to 2012) °F
(2012 to 2200) °F
11 °F
5.8 °F
4.7 °F
4.6 °F
2.0 °F
1.4 °F
2.2 °F
2.7 °F
2.2 °F
3.6 °F
Type S thermocouple
measurement system
& dry well furnace | to 15000 psig |
| 9 | AMS2750 | - | See scope document |
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1619.01) 09/22/2025 Page 10 of 10
V. Time & Frequency
Parameter/Equipment
Range CMC2, 7 (±) Comments
Time Elapsed3–
Measure
1 min to 1 hr
1.2 s
Digital stopwatch
__________________________________________
1 This laboratory offers commercial and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavi or of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC a % refers to a percent of reading unless otherwise noted.
5 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMCs are expressed as eithe r a specific value that covers the full range or as a
fraction/percentage of the reading plus a fixed floor specification.
6 This scope meets A2LA’s P112 Flexible Scope Policy.
7 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 11 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Fischer Technology, Inc. USAWindsor, CT · ~7 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Technical Maintenance, Inc. - WINDSORWindsor, CT · ~7 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Quality PlusChicopee, MA · ~35 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- CONNECTICUT CALIBRATION TECHNOLOGIES, INC., dba CONNECTICUT CALIBRATIONNewtown, CT · ~78 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- M Precision Laboratories,Shirley, MA · ~109 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.