FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
Poland

Silesia Lab Sp. z o.o.

Aleja Walentego Roździeńskiego 91, 40-203, Katowice, Poland

PCA|AB 1648ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
7
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Silesia Lab Sp. z o.o.?

Claim this profile to keep it accurate.

Register record

PCARefreshed
AB 1648Active

Certificates and scope

1
PCA

ISO/IEC 17025

Active

AB 1648

The scope document we hold says it is valid until 2029-06-07.

View on PCA

Accredited scope, certificate AB 1648

LineDisciplineMethodMatrixRange
1environmental-środowisko pracy (czynniki szkodliwe – powietrze); środowisko pracy (czynniki szkodliwe i uciążliwe – pole elektromagnetyczne, drgania, oświetlenie, mikroklimat, hałas, wydatek energetyczny); środowisko ogólne (czynniki fizyczne – hałas)-
2environmentalPN-N-01307:1994; PN-EN ISO 9612:2011; Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj.Dz.U. 2023, poz. 1706); PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11Workplace environment0.3 to 140 dB; m/s2
3environmentalPN-EN 14253+A1:2011; PB-01; PN-EN 1838:2013-11; PB-03Workplace environment0.03 to 20 m/s²
4environmentalPN-EN ISO 7730:2006; PN-EN ISO 7730:2006/Ap2:2016-04; PN-EN ISO 7243:2018-01; PN-EN ISO 11079:2008Workplace environment10 to 60 0C; %; m/s
5environmentalPN-Z-04008-7:2002; PN-Z-04008-7:2002/Az1:2004; PN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08Ambient air0.19 to 25 mg/m3
6environmentalPN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08; PB-02Ambient air0.05 to 235.5 mg/m3; ppm
7environmentalPN-T-06580-3:2002; Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 151 - 180; Podstawy i Metody Oceny Środowiska Pracy 2016. Nr 4 (90) s. 91-150; Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92) s. 89 - 131Workplace environment0.01 to 6000000000 Hz; V/m; kV/m; µT; mT; A/m; GHz

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Aleja Walentego Roździeńskiego 91, Katowice, 40-203, PL

50.26826, 19.05519

Open in Maps

Accreditation data refreshed from the PCA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.