Nordic Paper Seffle
Forskningsvägen 2, 661 31, Säffle, Sweden
- Accredited standards
- 5
- SWEDAC certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the SWEDAC scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 5 standard numbers and the 5 official names we hold. When no standard matches, it searches the method text of every scope line.
EN 872Water quality - Determination of suspended solids - Method by filtration through glass fibre filters
EN 27888Water quality - Determination of electrical conductivity
ISO 5667-6Water quality - Sampling - Part 6: Guidance on sampling of rivers and streams
ISO 10523Water quality - Determination of pH
ISO 17289Water quality - Determination of dissolved oxygen - Optical sensor method
SS-EN ISO/IEC 17025:2018 Nordic Paper Seffle AB S; SS-EN ISO 5667-6:2016 Ja Avloppsvatten; SS-EN 27888; SS-EN ISO 10523:2012 Elektrod 3-10 pH-enheter Avloppsvatten/Lakvatten Nej Elektrod 3-10 pH-enheter S; SS-EN 872:2005 Gravimetri
SS-EN ISO/IEC 17025:2018; SS-EN ISO 5667-6:2016; SS 028148; SS 028138; Hach Lange LCK 214/814; SS-EN 27888; SS-EN ISO 10523:2012; SS-EN 872:2005; ISO 17289:2014
Read from the scope as published by SWEDAC. Register refreshed 2026-11-08.
Scope as published by SWEDAC
2 lines
ISO/IEC 17025
Activea000347-001
Accredited scope, certificate a000347-001
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | SS-EN ISO/IEC 17025:2018 Nordic Paper Seffle AB S; SS-EN ISO 5667-6:2016 Ja Avloppsvatten; SS-EN 27888; SS-EN ISO 10523:2012 Elektrod 3-10 pH-enheter Avloppsvatten/Lakvatten Nej Elektrod 3-10 pH-enheter S; SS-EN 872:2005 Gravimetri | Fresh water | See scope document |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveA000347-001
Accredited scope, certificate A000347-001
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | SS-EN ISO/IEC 17025:2018; SS-EN ISO 5667-6:2016; SS 028148; SS 028138; Hach Lange LCK 214/814; SS-EN 27888; SS-EN ISO 10523:2012; SS-EN 872:2005; ISO 17289:2014 | Fresh water | See scope document |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Sweden
- SGS Analytics SwedenKarlstad · ~42 kmSWEDACShares 1 accredited materialFresh water
- Eurofins Water Testing SwedenLidköping · ~72 kmSWEDACShares 1 accredited materialFresh water
- AK Lab ABBorås · ~157 kmSWEDACShares 1 accredited test methodEN 872:2005 Gravimetri
- Microbial Analytics SwedenMölnlycke · ~172 kmSWEDACShares 1 accredited materialFresh water
- SGS Analytics SwedenLinköping · ~174 kmSWEDACShares 1 accredited materialFresh water
Accreditation data refreshed from the SWEDAC register on .