GRUPA INTERLIS
ul. Zielona 18, 62-800, Kalisz, Poland
- Accredited standards
- 14
- PCA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the PCA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 14 standard numbers and the 9 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO6
ISO 5349-1Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 1: General requirements
ISO 5349-2Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 2: Practical guidance for measurement at the workplace
ISO 7243Ergonomics of the thermal environment - Assessment of heat stress using the WBGT (wet bulb globe temperature) index
ISO 7730Ergonomics of the thermal environment - Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria
ISO 9612Acoustics - Determination of occupational noise exposure - Methodology
ISO 11079Ergonomics of the thermal environment - Determination and interpretation of cold stress when using required clothing insulation (IREQ) and local cooling effects
Other standards8
EN 1838
EN 14253Mechanical vibration - Measurement and evaluation of occupational exposure to whole-body vibration with reference to health - Practical guidance
PN-83/E-04040.03
PN-N-01307:1994Hałas - Dopuszczalne wartości hałasu w środowisku pracy - Wymagania dotyczące wykonywania pomiarów
PN-Z-01339
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05Ochrona czystości powietrza - Oznaczanie frakcji wdychalnej aerozolu na stanowiskach pracy metodą grawimetryczną
PN-Z-04508:2022-05
PN-EN ISO 7730:2006; PN-EN ISO 7730:2006/Ap2:2016-04; GR-INT/PB-06; PN-EN 14253+A1:2011; PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11
Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), str. 117-130; PN-83/E-04040.03; PN-EN 1838:2013-11; PN-EN ISO 11079:2008; PN-EN ISO 7243:2018-01
PN-EN ISO 11079:2008; PN-EN ISO 7243:2018-01; PN-EN ISO 7730:2006; PN-EN ISO 7730:2006/Ap2:2016-04
PN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08; GR-INT/PB-07; PN-N-01307:1994; PN-EN ISO 9612:2011
PN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08; PN-N-01307:1994; PN-EN ISO 9612:2011; PN-83/E-04040.03
PN-N-01307:1994; PN-EN ISO 9612:2011; PN-83/E-04040.03
PN-Z-01339:2020-12
PN-Z-04008-7:2002 +Az1:2004; PN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04008-7: 2002 +Az1:2004; PN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04008-7: 2002+Az1:2004; PN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08; PN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08
Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-06.
Scope as published by PCA
17 lines
ISO/IEC 17025
ActiveAB 896
The scope document we hold says it is valid until 2028-04-13.
Location
Labs with overlapping accredited scope in Poland
- LAB-SERWIS Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek SierocińskiCzęstochowa · ~128 kmPCAShares 7 accredited methods and materialsPN-83/E-04040.03PN-N-01307:1994PN-Z-04507:2022-05
- Zakład Usług Technicznych "ZUT" S.C. Bożena i Waldemar SzleperCzęstochowa · ~128 kmPCAShares 7 accredited methods and materialsEN ISO 7730:2006PN-83/E-04040.03PN-Z-04508:2022-05
- Zakład Ochrony Środowiska i Higieny Pracy "BIOSAN" Gizela Kalinowska, Ryszard KalinowskiPiła · ~177 kmPCAShares 7 accredited methods and materialsEN ISO 7730:2006PN-N-01307:1994PN-Z-04507:2022-05
- SBB Laboratorium Badań i EkspertyzKatowice · ~184 kmPCAShares 7 accredited methods and materialsEN ISO 7730:2006PN-83/E-04040.03PN-N-01307:1994
- GRUPA EKOPROJEKTBielsko-Biała · ~226 kmPCAShares 7 accredited methods and materialsEN ISO 11079:2008PN-N-01307:1994PN-Z-04507:2022-05
Accreditation data refreshed from the PCA register on .