Eurofins TA Technology (Shanghai) Co.,
Building 3, No. 145 Jintang Rd., Pudong New District, Shanghai 201201, People's Republic of China, Shanghai 201201, China
Visit website- Accredited standards
- 68
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 68 standard numbers and the 28 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC20
IEC 50332-1
IEC 50332-2
IEC 60065+1 national
National versions in the same scope
AS/NZS 60065probably the same standard; matched by number only
IEC 60601-1Medical electrical equipment - Part 1: General requirements for basic safety and essential performance+1 national
National versions in the same scope
AS/NZS IEC 60601.1probably the same standard; matched by number only
IEC 60950-1Information technology equipment - Safety - Part 1: General requirements+1 national
National versions in the same scope
AS/NZS 60950.1national version with changes
IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
IEC 61851-21-2
IEC 62040-2Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements
IEC 62209-1
IEC 62209-2
IEC 62232
IEC 62233Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure
Show all 20
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements+1 national
National versions in the same scope
AS/NZS 62368.1national version with changes
IEC 62368-3
IEC 62369-1
IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
IEC 62493
IEC 62680-1-2
IEC 62680-1-3
ETSI15
ETSI EN 301 549
ETSI TS 103 701
ETSI TS 134 121-1
ETSI TS 136 101
ETSI TS 136 508
ETSI TS 136 521-1
ETSI TS 136 521-3
ETSI TS 138 101-1
ETSI TS 138 101-3
ETSI TS 138 508-1
ETSI TS 138 508-2
ETSI TS 138 521-1
ETSI TS 138 521-3
ETSI TS 151 010-1
ETSI TS 151 010-2
EN9
EN 50332-1
EN 50332-2
EN 50360
EN 50364
EN 50385
EN 50566
EN 50663Generic standard for assessment of low power electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (10 MHz - 300 GHz)
EN 50664
EN 50665
CISPR6
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+1 national
National versions in the same scope
AS/NZS CISPR 14.1national version with changes
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard+1 national
National versions in the same scope
AS/NZS CISPR 14.2national version with changes
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+2 national
National versions in the same scope
AS CISPR 15national version with changes
AS/NZS CISPR 15national version with changes
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+2 national
National versions in the same scope
AS/NZS CISPR 32identical to it
VCCI-CISPR 32probably the same standard; matched by number only
IEC 61000 series6
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61326 series4
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications
IEC 61326-2-2Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems
IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment
EN 18031 series3
EN 18031-1
EN 18031-2
EN 18031-3
Other standards5
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
FCC PART 15Radio Frequency Devices
IEEE Std 1528:2013
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
RSS-102
FIRA CONSORTIUM UWB MAC TECHNICAL REQUIREMENTS; FiRa USB VCOM Technical Requirements; Matter CSA Matter Test Plans All Clusters; Matter Test Plans Core; GB 4943.1; YD/T 965; EN 60950-1; IEC 60950-1; AS/NZS 60950.1; IEC 60065; EN 60065; AS/NZS 60065; IEC 62368-1; EN 62368-1; UL 62368-1; AS/NZS 62368.1; EN IEC 62368-1; BS EN 62368-1; BS EN IEC 62368-1; EN 62368-3; IEC 62368-3; BS EN IEC 62368-3; EN IEC 62368-3; IEC 61010-1; EN 61010-1; BS EN61010-1; EN 50332-1; IEC 50332-1; BS EN 50332-1; EN 50332-2; IEC 50332-2; BS EN50332-2; IEC 60601-1; EN 60601-1; BS EN 60601-1; AS/NZS IEC 60601.1; GB 9706.1; EN 18031-1; BS EN 18031-1; EN 18031-2; BS EN 18031-2; EN 18031-3; BS EN 18031-3; ETSI TS 103 701
BS EN IEC 55014-1; EN IEC 55014-1; EN 55014-2; EN IEC 55014-2; BS EN 55014-2; BS EN IEC 55014-2; AS/NZS CISPR 14.1; AS/NZS CISPR 14.2; EN 55015; EN IEC 55015; BS EN IEC 55015; AS CISPR 15; AS/NZS CISPR 15; EN 55011; EN IEC 55011; CISPR 11; GB 4824; BS EN 55011; BS EN IEC 55011; EN 61326-1; BS EN 61326-1; BS EN IEC 61326-1; IEC 61326-1; EN IEC 61326-1; EN 61326-2-1; IEC 61326-2-1; BS EN 61326-2-1; EN IEC 61326-2-1; BS EN IEC 61326-2-1; EN 61326-2-2; IEC 61326-2-2; EN IEC 61326-2-2; BS EN 61326-2-2; BS EN IEC 61326-2-2; EN 61326-2-6; IEC 61326-2-6; BS EN 61326-2-6; BS EN IEC 61326-2-6; EN IEC 61326-2-6; BS EN IEC 62040-2; EN 62040-2; IEC 62040-2; EN IEC 62040-2; GB/T 21437.2; ISO 7637-2; ITU-T K.20; ITU-T K.21; ITU-T K.44; IEC 61851-21-2; EN IEC 61851-21-2; BS EN IEC 61851-21-2; GB/T 18487.2; ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024 + Errata to C63.10a-2024; ANSI C63.10:2020; ANSI C63.17:2013; FCC KDB Publication 905462; ANSI/TIA-603-E; KDB Publication 971168; ANSI C63.26:2015; ANSI C63.27-2017; AAMI TIR69:2017; ANSI/USEMCSC C63.27-2021; RSS-Gen; RSS-119; RSS-130; RSS-132; RSS-133; RSS-139; RSS-140; RSS-192; RSS-195; RSS-196; RSS-197; RSS-198; RSS-199; RSS-210; RSS-216; RSS-220; RSS-247; RSS-248
Article 34-8-8; Article 34-8-9; Article 34-8-10; Article 34-8-11; Article 34-8-12; Article 2 Paragraph 1 Item 79; Article 2 Paragraph 1 Item 80; Article 2 Paragraph 1 of Item 19-2-2; Article 2 Paragraph 1 of Item 21-3; Article 2 Paragraph 1 of Item 11-34; Article 2 Paragraph 1 of Item 54-6; Article 2 Paragraph 1 of Item 11-19-2; Article 2 Paragraph 1 of Item 11-19-3; Article 2 Paragraph 1 of Item 47; Article 2 Paragraph 1 of Item 47-3; Article 2 Paragraph 1 of Item 47-4; Article 2 Paragraph 1 of Item 72; Article 2 Paragraph 1 of Item 78; Article 49-6-4; Article 49-8-2-3; Article 49-6-9; Article 49-6-10; Article 49-6-13; Article 49-29; Article 49-29-2; Article 49-6-12; Ordinance Concerning Terminal Facilities etc. (Ministerial Ordinance of the Ministry of Posts and Telecommunications No.31), Article 3 to 9; 3GPP TS 34.114; 3GPP TR 25.914; 3GPP TR 37.902; 3GPP TS 25.144; 3GPP TS 37.544; 3GPP TR 37.977; CTIA and Wi-Fi Alliance Test Plan for RF Performance Evaluation of Wi-Fi Mobile Converged Devices3,4; ANSI/IEEE Std 149; CTIA-01.20; CTIA-01.50; CTIA-01.70; CTIA-01.71; CTIA-01.72; CTIA-01.73; CTIA-01.90; IEEE 1528; IEEE 1528a; ANSI C95.1; IEEE C95.1; IEEE C95.1a; RSS-102; RSS-102.SAR.MEAS; IEEE C95.3; IEEE C95.1; IEEE C95.1a; ANSI C95.1; IEEE C95.3; ANSI C95.3; IEEE 1528:2013; IEEE 1528a; ICNIRP Guidelines; EN 50360; EN 50566; EN 50364; EN 50385; IEC 62209-1; EN 62209-1; IS/IEC 62209-1; EN 62209-2; IEC 62209-2; IEC 62232; EN 62232; EN IEC 62232
IEC 62311; EN 62311; EN 50664; EN 50665; IEC 62369; EN 62369; IEC 62479; EN 62479; EN 50663; AS/NZS 2772.2; BS EN 50360; BS EN 50364; BS EN 50566; BS EN 62209-1; BS EN 62209-2; BS EN IEC 62311; BS EN 62369-1; BS EN 62232; BS EN 50663; BS EN 62479; BS EN 50385; BS EN 50664; BS EN 50665; BS IEC/IEEE 62209-1528; IEC/IEEE 62209-1528; EN IEC/IEEE 62209-1528; BS EN IEC/IEEE 62209-1528; EN IEC 62311; BS EN 62233; EN 62233; IEC 62233; BS IEC 62233; ARIB STD-T56; ARPANSA Standard RPS S-1; IEC 62493; EN 62493; BS EN 62493; DIRECTIVE (EU) 2019/882 EN 301 549; Common Charger IEC 62680-1-2; BS EN IEC 62680-1-2; EN IEC 62680-1-2; SASO IEC 62680-1-2; IS/IEC 62680-1-2; BS EN IEC 62680-1-3; EN IEC 62680-1-3; IEC 62680-1-3; SASO IEC 62680-1-3; IS/IEC 62680-1-3; ETSI TS 134 121-1; 3GPP TS 34.121-1; ETSI TS 151 010-2; 3GPP TS 51.010-2; ETSI TS 151 010-1; 3GPP TS 51.010-1; ETSI TS 136 101; 3GPP TS 36.101; ETSI TS 136 508; 3GPP TS 36.508; ETSI TS 136 521-1; 3GPP TS 36.521-1; ETSI TS 136 521-3; 3GPP TS 36.521-3; 3GPP TS 38.101-1; 3GPP TS 38.101-3; 3GPP TS 38.508-1; 3GPP TS 38.508-2; 3GPP TS 38.521-1; 3GPP TS 38.521-3; ETSI TS 138 521-1; ETSI TS 138 521-3; ETSI TS 138 101-1; ETSI TS 138 101-3; ETSI TS 138 508-1; ETSI TS 138 508-2; WINNF-TS-0122 WInnForum CBRS CBSD Test Specification; CBRSA-TS-9001 CBRS Alliance OnGo Certification Test Plans
CFR 47, FCC Part 15 Subpart B; ANSI C63.4:2014; CFR 47, FCC Part 18; MP-5:1986; CISPR 22:2008; EN 55022:2010; CISPR 32; EN 55032; AS/NZS CISPR 32; BS EN 55032; ICES-001; ICES-003; ICES-005; GB/T 9254.1; VCCI-CISPR 32; GB 17625.1; IEC 61000-3-2; EN 61000-3-2; BS EN IEC 61000-3-2; EN IEC 61000-3-2; GB 17625.2; IEC 61000-3-3; EN 61000-3-3; BS EN 61000-3-3; GB/T 17626.2; IEC 61000-4-2; EN 61000-4-2; EN IEC 61000-4-2; BS EN 61000-4-2; BS EN IEC 61000-4-2; GB/T 17626.3; IEC 61000-4-3; EN 61000-4-3; BS EN IEC 61000-4-3; EN IEC 61000-4-3; GB/T 17626.4; IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-4; GB/T 17626.5; IEC 61000-4-5; EN 61000-4-5; BS EN 61000-4-5; ISO/IEC 17025:2017
ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2020; ANSI C63.17:2013; FCC KDB Publication 905462 D02 (v02); ANSI/TIA-603-E; ANSI C63.26:2015
IEEE Std 1528:2013; FCC KDB 974614, Appendix A, Table A.1; 47 Code of Federal Regulations
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
10 lines
ISO/IEC 17025
Active3857.01
The scope document we hold says it is valid until 2027-11-30.
Labs with overlapping accredited scope in China
- BTL Inc. (Dongguan)Dongguan, GuangdongA2LAShares 3 accredited test methodsIEC 55014-1IEC 62368-1IEEE Std 1528:2013
- SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen BranchShenzhen, GuangdongA2LAShares 3 accredited test methodsANSI C63.4:2014EN 62311RSS-102
- Bureau Veritas Shenzhen Co., Ltd. Dongguan BranchDongguan City, Guangdong ProvinceA2LAShares 2 accredited test methodsIEC 55014-1IEC 62368-1
- Centre Testing International Group Co.,Shenzhen, GuangdongA2LAShares 2 accredited test methodsIEC 55014-1IEC 62368-1
- CTC Laboratories, Inc.Shenzhen, GuangdongA2LAShares 2 accredited test methodsANSI C63.4:2014IEC 62368-1
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.