Element Materials Technology - Hull

Unit E, South Orbital Trading Park, Hedon Road, Kingston upon Hull, HU9 1NJ, United Kingdom, Kingston upon Hull, United Kingdom

Visit website
A2LA 7493.01ISO/IEC 17025Register refreshed 2026-11-20
Part of the Element Materials Technology group: 127 sites in our directory.

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
24
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 24 standard numbers and the 17 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 61000 series11
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-9Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-39Electromagnetic compatibility (EMC) - Part 4-39: Testing and measurement techniques - Radiated fields in close proximity - Immunity test
IEC 60601 series7
IEC 60601-1Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 60601-1-6
IEC 60601-1-8
IEC 60601-1-11Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
IEC 60601-1-12
IEC 60601-2-24
IEC3
IEC 62304
IEC 62366-1
IEC 80601-2-49Some clauses

Limits written next to it

IEC 80601-2-49:2018 Ed.1.0 (Only Section 202.8.102)

Some clauses. Written next to it on line 2 of A2LA certificate 7493.01.

Other standards3
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
ISO 14708-4Implants for surgery - Active implantable medical devices - Part 4: Implantable infusion pump systemsSome clauses

Limits written next to it

ISO 14708-4 Ed 1.0 (2008-11-15) – (Only Section 27.103 and

Some clauses. Written next to it on line 2 of A2LA certificate 7493.01.

ISO 14708-4 Ed 2.0 (2022-02) – (Only Section 27.103 and Section

Some clauses. Written next to it on line 2 of A2LA certificate 7493.01.

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Active

7493.01

The scope document we hold says it is valid until 2027-06-30.

View scope

Accredited scope, certificate 7493.01

LineMethodMatrixRange
1IEC 60601-1; ANSI AAMI ES60601-1:2005/(R)2012 & A1:2012, C1:2009/(R)2012 & A2:2010/(R)2012; CAN/CSA-C22.2 NO. 60601-1:14/A2:22 (R2022); IEC 60601-1-8; ANSI AAMI IEC 60601-1-8:2006 and A1:2012; CSA CAN/CSA-C22.2 No. 60601-1-8:08; IEC 60601-1-11; IEC 60601-1-6; CSA CAN/CSA-C22.2 No. 60601-1-6:11; IEC 62366-1:2020; IEC 62304:2015; IEC 60601-1-12; ANSI AAMI IEC 60601-1-12:2016; CSA CAN/CSA-C22.2 No. 60601-1-12:15 + A1:21; IEC 60601-1-11:2015; IEC 60601-2-24:2012--
2IEC 60601-1-2 Edition 4.1 2020-09 CONSOLIDATED VERSION; ANSI AAMI IEC 60601-1-2:2014 [Including AMD 1:2021]; ISO 14708-4 Ed 2.0 (2022-02); ISO 14708-4 Ed 1.0 (2008-11-15); IEC 80601-2-49:2018 Ed.1.0; AIM Standard 7351731 Rev. 3.00 2021-06-04; CISPR 11:2015 +A1:2016 & A2:2019; CISPR 11; CISPR 32:2015; CISPR 32; EN/IEC 61000-3-2:2005 +A1:2008 & A2:2009; EN/IEC 61000-3-2; EN/IEC 61000-3-3:2013; EN/IEC 61000-3-3; EN/IEC 61000-4-2:2008; EN/IEC 61000-4-2; EN/IEC 61000-4-3:2006 +A1:2007 & A2:2010; EN/IEC 61000-4-3; EN/IEC 61000-4-4:2012; EN/IEC 61000-4-4; EN/IEC 61000-4-5:2005; EN/IEC 61000-4-5; EN/IEC 61000-4-6:2013; EN/IEC 61000-4-6; EN/IEC 61000-4-8:2009; EN/IEC 61000-4-8; EN/IEC 61000-4-9:2016; EN/IEC 61000-4-9; EN/IEC 61000-4-11:2004; EN/IEC 61000-4-11; EN/IEC 61000-4-39:2017; EN/IEC 61000-4-39; CISPR 25 Ed 4.0:2016; CISPR 25--
3EN 50121-3-2:2016+A1:2019; EN 50121-3-2--
4

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited ELEMENT MATERIALS TECHNOLOGY - HULL Kingston upon Hull, United Kingdom for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets A2LA R256 - Specific Requirements - FDA ASCA Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 2nd day of June 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 7493.01 Valid to June 30, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.