ELECTRICAL TEST INSTRUMENTS

Cornelius, NC, United States

A2LA 5636.02ISO/IEC 17025Register refreshed 2026-10-23

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
13
A2LA certificate
1
Sites in our directory
3
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 13 scope lines.

A2LA certificate 5636.02 · 13 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5636.02) 3/24/2026 Page 2 of 12 Parameter/Equipment Range CMC2, 5 (±) Comments Indicators3 (0.0001 to 1.5) in 2.5 µm to 38.1 mm (58 + 1L) µin (1.5 + 0.001L) µm Gage blocks Gage blocks Height Gages3 (0.05 to 24) in (1.27 to 609.6) mm (120 + 9L) µin (2.9 + 0.009L) µm Mitutoyo 515-565, Starrett 234A Mitutoyo 515-565, Starrett 234A III. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4 (±) Comments DC Voltage – Measure3 72 µV to 330 mV 330 mV to 3.3 V (3.3 to 33) V (30 to 330) V (100 to 1020) V 4.3 µV + 0.006 % 18 µV + 0.005 % 200 µV + 0.005 % 2 mV + 0.0055 % 1.5 mV + 0.0055 % Fluke 5500A DC Voltage – Generate3 (2.4 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V 1 µV + 0.0007 % 1 µV + 0.0006 % 2 µV + 0.0006 % 32 µV + 0.0008 % 10 mV + 0.0008 % HP 3458A opt 002 DC Current – Measure3 Toroidal Clamp-On (1.44 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 2.2) A (2.2 to 11) A (11 to 16.5) A (16.5 to 150) A (150 to 550) A 0.05 µA + 0.013 % 0.25 µA + 0.01 % 3.3 µA + 0.01 % 44 µA + 0.03 % 330 µA + 0.06 % 0.002 A + 0.25 % 0.015 A + 0.25 % 0.05 A + 0.25 % Fluke 5500A Fluke 5500A w/ coil
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5636.02) 3/24/2026 Page 3 of 12 Parameter/Equipment Range CMC2, 4 (±) Comments DC Current – Generate3 (0.13 to 100) nA 100 nA to 1 µA (1 to 10) µA (10 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A 0.04 nA + 0.0035 % 0.04 nA + 0.0025 % 0.1 nA + 0.0025 % 0.8 nA + 0.0025 % 5 nA + 0.0025 % 50 nA + 0.0025 % 0.5 µA + 0.004 % 10 µA + 0.012 % HP 3458A opt 002 DC Resistance – Measure 3 50 mΩ to 11 Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω 330 Ω to 1.1 kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ 330 kΩ to 1.5 MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ 0.008 Ω + 0.012 % 0.015 Ω + 0.012 % 0.015 Ω + 0.009 % 0.015 Ω + 0.009 % 0.061 Ω + 0.009 % 0.078 Ω + 0.009 % 0.66 Ω + 0.009 % 0.81 Ω + 0.009 % 6.7 Ω + 0.011 % 8.7 Ω + 0.012 % 65 Ω + 0.015 % 110 Ω + 0.015 % 740 Ω + 0.06 % 6600 Ω + 0.1 % 26 kΩ + 0.5 % 88 kΩ + 0.5 % Fluke 5500A DC Resistance – Generate 3 (0.005 to 10) Ω (10 to 100) Ω 100 Ω to 1 kΩ (1 to 10) kΩ (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ (10 to 100) MΩ 100 MΩ to 1 GΩ 0.000 05 Ω + 0.0018 % 0.000 05 Ω + 0.0015 % 0.000 05 Ω + 0.0013 % 0.005 Ω + 0.0013 % 0.05 Ω + 0.0013 % 2 Ω + 0.0018 % 100 Ω + 0.0053 % 1 kΩ + 0.051 % 10 kΩ + 0.51 % HP 3458A opt 002
4-AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5636.02) 3/24/2026 Page 4 of 12 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Measure3 (1 to 33) mV (33 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 23 µV + 0.35 % 23 µV + 0.15 % 23 µV + 0.2 % 23 µV + 0.25 % 40 µV + 0.35 % 170 µV + 1 % 73 µ V + 0.25 % 43 µ V + 0.05 % 44 µV + 0.l % 71 µV + 0.16 % 230 µV + 0.24 % 1.3 mV + 0.7 % 480 µV + 0.15 % 290 µV + 0.03 % 290 µV + 0.08 % 610 µV + 0.14 % 2.3 mV + 0.24 % 13 mV + 0.5 % 7 mV + 0.15 % 3.6 mV + 0.04 % 5.6 mV + 0.08 % 9.2 mV + 0.19 % 22 mV + 0.24 % 40 mV + 0.05 % 30 mV + 0.08 % 30 mV + 0.09 % 130 mV + 0.05 % 100 mV + 0.2 % 500 mV + 0.2 % Fluke 5500A
See scope document
5-AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5636.02) 3/24/2026 Page 5 of 12 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Generate3 18 µV to 10 mV 9.3 µV to 10 mV 12.3 µV to 10 mV µV to 10 mV 153.3 µV to 10 mV (1.2 to 10) mV (10 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 3 µV + 0.03 % 1.1 µV + 0.02 % 1.1 µV + 0.03 % 1.1 µV + 0.1 % 1.1 µV + 0.5 % 2 µV + 4 % 4 µV + 0.007 % 2 µV + 0.007 % 2 µV + 0.014 % 2 µV + 0.03 % 2 µV + 0.08 % 10 µV + 0.3 % 10 µV + 1 % 10 µV + 1.5 % 40 µV + 0.007 % 20 µV + 0.007 % 20 µV + 0.014 % 20 µV + 0.03 % 20 µV + 0.08 % 100 µV + 0.3 % 100 µV + 1 % 100 µV + 1.5 % 400 µV + 0.007 % 200 µV + 0.007 % 200 µV + 0.014 % 200 µV + 0.03 % 200 µV + 0.08 % 1 mV + 0.3 % 1 mV + 1 % 1 mV + 1.5 % 4 mV + 0.02 % 2 mV + 0.02 % 2 mV + 0.02 % 2 mV + 0.035 % 2 mV + 0.12 % 10 mV + 0.4 % 10 mV + 1.5 % 40 mV + 0.04 % 20 mV + 0.04 % 20 mV + 0.06 % 20 mV + 0.12 % 20 mV + 0.3 % HP 3458A opt 002
See scope document
6-AC Current
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5636.02) 3/24/2026 Page 6 of 12 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Measure3 (0.029 to 0.3299) mA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 2.2) A (2.2 to 11) A Toroidal Clamp-On: (10 to 16.5) A (16.5 to 150) A (150 to 550) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (45 to 65) Hz (65 to 500) Hz 500 Hz to 1 kHz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 0.23 µA + 0.25 % 0.49 µA + 0.13 % 0.58 µA + 0.13 % 0.64 µA + 0.4 % 1.4 µA + 1.3 % 0.76 µA + 0.2 % 0.8 µA + 0.1 % 0.72 µA + 0.1 % 0.79 µA + 0.2 % 0.79 µA + 0.6 % 3 µA + 0.2 % 3 µA + 0.l % 3 µA + 0.09 % 3 µA + 0.2 % 3 µA + 0.6 % 30 µA + 0.2 % 30 µA + 0.1 % 30 µA + 0.09 % 30 µA + 0.2 % 30 µA + 0.6 % 300 µA + 0.2 % 300 µA + 0.1 % 300 µA + 0.75 % 2000 µA + 0.06 % 2000 µA + 0.1 % 2000 µA + 0.33 % 0.003 A + 0.28 % 0.003 A + 0.79 % 0.025 A + 0.28 % 0.027 A + 0.79 % 0.09 A + 0.28 % 0.1 A + 0.79 % Fluke 5500A Fluke 5500A w/ coil
See scope document
7-AC Current; Inductance
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5636.02) 3/24/2026 Page 7 of 12 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Generate3 (1.3 to 100) µA (0.51 to 100) µA (0.24 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A (10 to 20) Hz (20 to 45) Hz 45 Hz to 5 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz 0.03 µA + 0.4 % 0.03 µA + 0.15 % 0.03 µA + 0.06 % 0.2 µA + 0.4 % 0.2 µA + 0.15 % 0.2 µA + 0.06 % 0.2 µA + 0.03 % 0.2 µA + 0.06 % 0.4 µA + 0.4 % 1.5 µA + 0.55 % 2 µA + 0.4 % 2 µA + 0.15 % 2 µA + 0.06 % 2 µA + 0.03 % 2 µA + 0.06 % 4 µA + 0.4 % 15 µA + 0.55 % 20 µA + 0.4 % 20 µA + 0.15 % 20 µA + 0.06 % 20 µA + 0.03 % 20 µA + 0.06 % 40 µA + 0.4 % 150 µA + 0.55 % 0.2 mA + 0.4 % 0.2 mA + 0.16 % 0.2 mA + 0.08 % 0.2 mA + 0.1 % 0.2 mA + 0.3 % 0.4 mA + 1 % HP 3458A opt 002 Inductance – Generate3 (Fixed Points) 100 mH 100 Hz 200 Hz 400 Hz 1000 Hz 10 kHz 0.12 mH 0.12 mH 0.12 mH 0.12 mH 0.13 mH General Radio 1482-L
See scope document
8-thermocouple indicators
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5636.02) 3/24/2026 Page 8 of 12 Parameter/Equipment Range CMC2, 4 (±) Comments Capacitance – Measure3 (0.33 to 11) nF (11 to 110) nF (110 to 330) nF (0.33 to 1.1) µF (1.1 to 3.3) µF (3.3 to 11) µF (11 to 33) µF (33 to 110) µF (110 to 330) µF 330 µF to 1.1 mF 0.01 nF + 0.5 % 0.01 nF + 0.25 % 0.3 nF + 0.25 % 1 nF + 0.25 % 3 nF + 0.35 % 10 nF + 0.35 % 30 nF + 0.4 % 100 nF + 0.5 % 300 nF + 0.7 % 300 nF + 1 % Fluke 5500A Electrical Calibration of Thermocouple Indicators3 Type B Type E Type J Type K Type N (250 to 350) °C (350 to 445) °C (445 to 580) °C (580 to 750) °C (750 to 1000) °C (1000 to 1820) °C (-270 to -245) °C (-245 to -195) °C (-195 to -155) °C (-155 to -90) °C (-90 to 15) °C (15 to 890) °C (890 to 1000) °C (-210 to -180) °C (-180 to -120) °C (-120 to -50) °C (990 to 1200) °C (-270 to -255) °C (-225 to -195) °C (-195 to 115) °C (-115 to -55) °C (-55 to 1000) °C (1000 to 1372) °C (-270 to -260) °C (-260 to -200) °C (-200 to -140) °C (-140 to -70) °C (-70 to 25) °C (25 to 160) °C (160 to 1300) °C 0.95 °C 0.74 °C 0.58 °C 0.45 °C 0.37 °C 0.17 °C 1.2 °C 0.18 °C 0.1 °C 0.08 °C 0.07 °C 0.06 °C 0.07 °C 0.12 °C 0.1 °C 0.08 °C 0.07 °C 2.2 °C 0.7 °C 0.12 °C 0.09 °C 0.07 °C 0.08 °C 5 °C 1 °C 0.23 °C 0.15 °C 0.12 °C 0.1 °C 0.09 °C Ectron 1140A
See scope document
9-thermocouple indicators; RTDs; oscilloscopes
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5636.02) 3/24/2026 Page 9 of 12 Parameter/Equipment Range CMC2, 6 (±) Comments Electrical Calibration of Thermocouple Indicators3 (cont) Type R Type S Type T (-50 to -30) °C (-30 to 45) °C (45 to 160) °C (160 to 380) °C (380 to 775) °C (775 to 1768.1) °C (-50 to -30) °C (-30 to 45) °C (45 to 105) °C (105 to 310) °C (310 to 615) °C (615 to 1768.1) °C (-270 to -255) °C (-255 to -240) °C (-240 to -210) °C (-210 to -150) °C (-150 to -40) °C (-40 to 100) °C (100 to 400) °C 0.65 °C 0.55 °C 0.4 °C 0.3 °C 0.26 °C 0.22 °C 0.62 °C 0.56 °C 0.4 °C 0.33 °C 0.29 °C 0.26 °C 1.8 °C 0.49 °C 0.3 °C 0.18 °C 0.12 °C 0.08 °C 0.07 °C Ectron 1140A Electrical Calibration of RTDs 3 Pt 385, 100 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C 0.05 °C 0.05 °C 0.07 °C 0.09 °C 0.1 °C 0.12 °C 0.23 °C Fluke 5500A Oscilloscopes3 – AC Voltage – Leveled Sine Wave – (50 Ω) 0.1 Hz to 300 MHz (300 to 550) MHz 550 MHz to 1.1 GHz (1.1 to 3.2) GHz 5 mVp-p to 5 Vp-p 5 mVp-p to 5 Vp-p 5 mVp-p to 3 Vp-p 5 mVp-p to 2 Vp-p 2.0 % 5.5 % 7.5 % 9.0 % Fluke 9500B / 9530
See scope document
10-AC Voltage; DC Voltage; Analytical Balances; Electronic Balances; Class 1 weights; Pressure Gages; Vacuum Gages
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5636.02) 3/24/2026 Page 10 of 12 Parameter/Equipment Range CMC2, 6 (±) Comments Oscilloscopes3 (cont) – AC Voltage – Amplitude Vp-p – (1 MΩ) 1 kHz DC Voltage – 1 MΩ 50 Ω 1 mV to 200 Vp-p 1 mV to +/-200 V 1 mV to +/-5 V l.0 % + 10 µV 0.025 % + 25 µV 0.025 % + 25 µV Fluke 9500B / 9530 IV. Mechanical Parameter/Equipment Range CMC2, 7 (±) Comments Scales & Balances3 – Analytical Balances Electronic Balances (50 to 500) g (50 to 2000) g (4.4 x 10 4 + 3 x 10-6Wt) g (1.2 x 10-2 + 1 x 10- 6Wt) g Class 1 weights Pressure Gages3 (0 to 6.89) kPa (0 to 68.947) kPa (0 to 1) psi (0 to 10) psi (0 to 2068) kPa (0 to 6894) kPa (0 to 34 473) kPa (0 to 300) psi (0 to 1000) psi (0 to 5000) psi 0.024 kPa 0.093 kPa 0.0035 psi 0.014 psi 0.56 kPa 3.5 kPa 28 kPa 0.081 psi 0.5 psi 4 psi Fluke 700P22 Druck DPI 610 w/ PDCR 2200-A145 Drunk DPI 611 Fluke 700P08 Fluke 700P30 Vacuum Gages3 (-755 to -2.5) mmHg (-29.72 to -0.098) inHg 4.1 mmHg 0.16 inHg Druck DPI 611
-
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5636.02) 3/24/2026 Page 11 of 12 Parameter/Equipment Range CMC2 (±) Comments Torque – Tools3 (0.28 to 2.8) N·m (2.825 to 28.25) N·m (33.9 to 339) N·m (25 to 250) lbf·in (25 to 250) lbf·ft 0.028 N·m 0.28 N·m 3.5 N·m 2.5 lbf·in 2.6 lbf·ft AWS QCI-25 Mountz BMX250I Mountz BMX250F Mountz BMX250I Mountz BMX250F V. Thermodynamics Parameter/Equipment Range CMC2, 8 (±) Comments Temperature – Measure3 (-20 to 0) °C (0 to 420) °C (420 to 670) °C 0.026 °C 0.046 °C 0.067 °C Additel ADT282 w/ Accumac AMI 751 Temperature – IR Measuring Equipment 3 (50 to 500) °C 2 °C Fluke 9132 Relative Humidity – Measure3 (Fixed Points) 11.3 % RH 75 % RH 97 % RH 1.3 % RH 1.5 % RH 2 % RH Vaisala 19729HM Vaisala 19731HM Vaisala 19732HM Relative Humidity – Measuring Equipment3 (10 to 90) % RH 1.2 % RH Vaisala HMI41 w/ HMP46 VI. Time & Frequency Parameter/Equipment Range CMC2 (±) Comments Stopwatches & Timers3 (5 to 180) min 0.098 s HP 53181A Tachometers – Mechanical3 (575 to 3500) rpm 0.4 rpm Automation Direct CCT-AN-A120 counter
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5636.02) 3/24/2026 Page 12 of 12 Parameter/Equipment Range CMC2, 6 (±) Comments Tachometers – Photo3 (60 to 100 000) rpm 1.2 rpm Fluke 5500A Oscilloscope – Time Markers3 (1,2,2.5,4,5 Sequence) 900.91 ns to 83 µs 83 µs to 55 s 0.000 025 % 0.0003 % Fluke 9500B/ 9530 __________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavi or of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., r esolution, repeatability) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 5 L is the numerical value of the nominal length of the device measured in inches or millimeters, 6 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. 7 Wt is the numerical value of the nominal mass of the device measured in grams. 8 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 9 This scope meets A2LA’s P112 Flexible Scope Policy.
13ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.