ELECTRICAL TEST INSTRUMENTS
Cornelius, NC, United States
- Scope lines
- 13
- A2LA certificate
- 1
- Sites in our directory
- 3
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 13 scope lines.
A2LA certificate 5636.02 · 13 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5636.02) 3/24/2026 Page 2 of 12
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Indicators3
(0.0001 to 1.5) in
2.5 µm to 38.1 mm
(58 + 1L) µin
(1.5 + 0.001L) µm
Gage blocks
Gage blocks
Height Gages3
(0.05 to 24) in
(1.27 to 609.6) mm
(120 + 9L) µin
(2.9 + 0.009L) µm
Mitutoyo 515-565,
Starrett 234A
Mitutoyo 515-565,
Starrett 234A
III. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Voltage – Measure3
72 µV to 330 mV
330 mV to 3.3 V
(3.3 to 33) V
(30 to 330) V
(100 to 1020) V
4.3 µV + 0.006 %
18 µV + 0.005 %
200 µV + 0.005 %
2 mV + 0.0055 %
1.5 mV + 0.0055 %
Fluke 5500A
DC Voltage – Generate3
(2.4 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
1 µV + 0.0007 %
1 µV + 0.0006 %
2 µV + 0.0006 %
32 µV + 0.0008 %
10 mV + 0.0008 %
HP 3458A opt 002
DC Current – Measure3
Toroidal Clamp-On
(1.44 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 2.2) A
(2.2 to 11) A
(11 to 16.5) A
(16.5 to 150) A
(150 to 550) A
0.05 µA + 0.013 %
0.25 µA + 0.01 %
3.3 µA + 0.01 %
44 µA + 0.03 %
330 µA + 0.06 %
0.002 A + 0.25 %
0.015 A + 0.25 %
0.05 A + 0.25 %
Fluke 5500A
Fluke 5500A w/ coil | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5636.02) 3/24/2026 Page 3 of 12
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Current – Generate3
(0.13 to 100) nA
100 nA to 1 µA
(1 to 10) µA
(10 to 100) µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
0.04 nA + 0.0035 %
0.04 nA + 0.0025 %
0.1 nA + 0.0025 %
0.8 nA + 0.0025 %
5 nA + 0.0025 %
50 nA + 0.0025 %
0.5 µA + 0.004 %
10 µA + 0.012 %
HP 3458A opt 002
DC Resistance –
Measure
3
50 mΩ to 11 Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
330 Ω to 1.1 kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
330 kΩ to 1.5 MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
0.008 Ω + 0.012 %
0.015 Ω + 0.012 %
0.015 Ω + 0.009 %
0.015 Ω + 0.009 %
0.061 Ω + 0.009 %
0.078 Ω + 0.009 %
0.66 Ω + 0.009 %
0.81 Ω + 0.009 %
6.7 Ω + 0.011 %
8.7 Ω + 0.012 %
65 Ω + 0.015 %
110 Ω + 0.015 %
740 Ω + 0.06 %
6600 Ω + 0.1 %
26 kΩ + 0.5 %
88 kΩ + 0.5 %
Fluke 5500A
DC Resistance –
Generate
3
(0.005 to 10) Ω
(10 to 100) Ω
100 Ω to 1 kΩ
(1 to 10) kΩ
(10 to 100) kΩ
100 kΩ to 1 MΩ
(1 to 10) MΩ
(10 to 100) MΩ
100 MΩ to 1 GΩ
0.000 05 Ω + 0.0018 %
0.000 05 Ω + 0.0015 %
0.000 05 Ω + 0.0013 %
0.005 Ω + 0.0013 %
0.05 Ω + 0.0013 %
2 Ω + 0.0018 %
100 Ω + 0.0053 %
1 kΩ + 0.051 %
10 kΩ + 0.51 %
HP 3458A opt 002 | ||
| 4 | - | AC VoltageShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5636.02) 3/24/2026 Page 4 of 12
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Measure3
(1 to 33) mV
(33 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
23 µV + 0.35 %
23 µV + 0.15 %
23 µV + 0.2 %
23 µV + 0.25 %
40 µV + 0.35 %
170 µV + 1 %
73 µ V + 0.25 %
43 µ V + 0.05 %
44 µV + 0.l %
71 µV + 0.16 %
230 µV + 0.24 %
1.3 mV + 0.7 %
480 µV + 0.15 %
290 µV + 0.03 %
290 µV + 0.08 %
610 µV + 0.14 %
2.3 mV + 0.24 %
13 mV + 0.5 %
7 mV + 0.15 %
3.6 mV + 0.04 %
5.6 mV + 0.08 %
9.2 mV + 0.19 %
22 mV + 0.24 %
40 mV + 0.05 %
30 mV + 0.08 %
30 mV + 0.09 %
130 mV + 0.05 %
100 mV + 0.2 %
500 mV + 0.2 %
Fluke 5500A | See scope document |
| 5 | - | AC VoltageShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5636.02) 3/24/2026 Page 5 of 12
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Generate3
18 µV to 10 mV
9.3 µV to 10 mV
12.3 µV to 10 mV
µV to 10 mV
153.3 µV to 10 mV
(1.2 to 10) mV
(10 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
3 µV + 0.03 %
1.1 µV + 0.02 %
1.1 µV + 0.03 %
1.1 µV + 0.1 %
1.1 µV + 0.5 %
2 µV + 4 %
4 µV + 0.007 %
2 µV + 0.007 %
2 µV + 0.014 %
2 µV + 0.03 %
2 µV + 0.08 %
10 µV + 0.3 %
10 µV + 1 %
10 µV + 1.5 %
40 µV + 0.007 %
20 µV + 0.007 %
20 µV + 0.014 %
20 µV + 0.03 %
20 µV + 0.08 %
100 µV + 0.3 %
100 µV + 1 %
100 µV + 1.5 %
400 µV + 0.007 %
200 µV + 0.007 %
200 µV + 0.014 %
200 µV + 0.03 %
200 µV + 0.08 %
1 mV + 0.3 %
1 mV + 1 %
1 mV + 1.5 %
4 mV + 0.02 %
2 mV + 0.02 %
2 mV + 0.02 %
2 mV + 0.035 %
2 mV + 0.12 %
10 mV + 0.4 %
10 mV + 1.5 %
40 mV + 0.04 %
20 mV + 0.04 %
20 mV + 0.06 %
20 mV + 0.12 %
20 mV + 0.3 %
HP 3458A opt 002 | See scope document |
| 6 | - | AC CurrentShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5636.02) 3/24/2026 Page 6 of 12
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Measure3
(0.029 to 0.3299) mA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 2.2) A
(2.2 to 11) A
Toroidal Clamp-On:
(10 to 16.5) A
(16.5 to 150) A
(150 to 550) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(45 to 65) Hz
(65 to 500) Hz
500 Hz to 1 kHz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
0.23 µA + 0.25 %
0.49 µA + 0.13 %
0.58 µA + 0.13 %
0.64 µA + 0.4 %
1.4 µA + 1.3 %
0.76 µA + 0.2 %
0.8 µA + 0.1 %
0.72 µA + 0.1 %
0.79 µA + 0.2 %
0.79 µA + 0.6 %
3 µA + 0.2 %
3 µA + 0.l %
3 µA + 0.09 %
3 µA + 0.2 %
3 µA + 0.6 %
30 µA + 0.2 %
30 µA + 0.1 %
30 µA + 0.09 %
30 µA + 0.2 %
30 µA + 0.6 %
300 µA + 0.2 %
300 µA + 0.1 %
300 µA + 0.75 %
2000 µA + 0.06 %
2000 µA + 0.1 %
2000 µA + 0.33 %
0.003 A + 0.28 %
0.003 A + 0.79 %
0.025 A + 0.28 %
0.027 A + 0.79 %
0.09 A + 0.28 %
0.1 A + 0.79 %
Fluke 5500A
Fluke 5500A w/ coil | See scope document |
| 7 | - | AC Current; InductanceShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5636.02) 3/24/2026 Page 7 of 12
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Generate3
(1.3 to 100) µA
(0.51 to 100) µA
(0.24 to 100) µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
0.03 µA + 0.4 %
0.03 µA + 0.15 %
0.03 µA + 0.06 %
0.2 µA + 0.4 %
0.2 µA + 0.15 %
0.2 µA + 0.06 %
0.2 µA + 0.03 %
0.2 µA + 0.06 %
0.4 µA + 0.4 %
1.5 µA + 0.55 %
2 µA + 0.4 %
2 µA + 0.15 %
2 µA + 0.06 %
2 µA + 0.03 %
2 µA + 0.06 %
4 µA + 0.4 %
15 µA + 0.55 %
20 µA + 0.4 %
20 µA + 0.15 %
20 µA + 0.06 %
20 µA + 0.03 %
20 µA + 0.06 %
40 µA + 0.4 %
150 µA + 0.55 %
0.2 mA + 0.4 %
0.2 mA + 0.16 %
0.2 mA + 0.08 %
0.2 mA + 0.1 %
0.2 mA + 0.3 %
0.4 mA + 1 %
HP 3458A opt 002
Inductance – Generate3
(Fixed Points)
100 mH
100 Hz
200 Hz
400 Hz
1000 Hz
10 kHz
0.12 mH
0.12 mH
0.12 mH
0.12 mH
0.13 mH
General Radio 1482-L | See scope document |
| 8 | - | thermocouple indicatorsShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5636.02) 3/24/2026 Page 8 of 12
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Capacitance – Measure3
(0.33 to 11) nF
(11 to 110) nF
(110 to 330) nF
(0.33 to 1.1) µF
(1.1 to 3.3) µF
(3.3 to 11) µF
(11 to 33) µF
(33 to 110) µF
(110 to 330) µF
330 µF to 1.1 mF
0.01 nF + 0.5 %
0.01 nF + 0.25 %
0.3 nF + 0.25 %
1 nF + 0.25 %
3 nF + 0.35 %
10 nF + 0.35 %
30 nF + 0.4 %
100 nF + 0.5 %
300 nF + 0.7 %
300 nF + 1 %
Fluke 5500A
Electrical Calibration of
Thermocouple Indicators3
Type B
Type E
Type J
Type K
Type N
(250 to 350) °C
(350 to 445) °C
(445 to 580) °C
(580 to 750) °C
(750 to 1000) °C
(1000 to 1820) °C
(-270 to -245) °C
(-245 to -195) °C
(-195 to -155) °C
(-155 to -90) °C
(-90 to 15) °C
(15 to 890) °C
(890 to 1000) °C
(-210 to -180) °C
(-180 to -120) °C
(-120 to -50) °C
(990 to 1200) °C
(-270 to -255) °C
(-225 to -195) °C
(-195 to 115) °C
(-115 to -55) °C
(-55 to 1000) °C
(1000 to 1372) °C
(-270 to -260) °C
(-260 to -200) °C
(-200 to -140) °C
(-140 to -70) °C
(-70 to 25) °C
(25 to 160) °C
(160 to 1300) °C
0.95 °C
0.74 °C
0.58 °C
0.45 °C
0.37 °C
0.17 °C
1.2 °C
0.18 °C
0.1 °C
0.08 °C
0.07 °C
0.06 °C
0.07 °C
0.12 °C
0.1 °C
0.08 °C
0.07 °C
2.2 °C
0.7 °C
0.12 °C
0.09 °C
0.07 °C
0.08 °C
5 °C
1 °C
0.23 °C
0.15 °C
0.12 °C
0.1 °C
0.09 °C
Ectron 1140A | See scope document |
| 9 | - | thermocouple indicators; RTDs; oscilloscopesShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5636.02) 3/24/2026 Page 9 of 12
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Electrical Calibration of
Thermocouple Indicators3
(cont)
Type R
Type S
Type T
(-50 to -30) °C
(-30 to 45) °C
(45 to 160) °C
(160 to 380) °C
(380 to 775) °C
(775 to 1768.1) °C
(-50 to -30) °C
(-30 to 45) °C
(45 to 105) °C
(105 to 310) °C
(310 to 615) °C
(615 to 1768.1) °C
(-270 to -255) °C
(-255 to -240) °C
(-240 to -210) °C
(-210 to -150) °C
(-150 to -40) °C
(-40 to 100) °C
(100 to 400) °C
0.65 °C
0.55 °C
0.4 °C
0.3 °C
0.26 °C
0.22 °C
0.62 °C
0.56 °C
0.4 °C
0.33 °C
0.29 °C
0.26 °C
1.8 °C
0.49 °C
0.3 °C
0.18 °C
0.12 °C
0.08 °C
0.07 °C
Ectron 1140A
Electrical Calibration of
RTDs
3
Pt 385, 100 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
0.05 °C
0.05 °C
0.07 °C
0.09 °C
0.1 °C
0.12 °C
0.23 °C
Fluke 5500A
Oscilloscopes3 –
AC Voltage –
Leveled Sine Wave –
(50 Ω)
0.1 Hz to 300 MHz
(300 to 550) MHz
550 MHz to 1.1 GHz
(1.1 to 3.2) GHz
5 mVp-p to 5 Vp-p
5 mVp-p to 5 Vp-p
5 mVp-p to 3 Vp-p
5 mVp-p to 2 Vp-p
2.0 %
5.5 %
7.5 %
9.0 %
Fluke 9500B / 9530 | See scope document |
| 10 | - | AC Voltage; DC Voltage; Analytical Balances; Electronic Balances; Class 1 weights; Pressure Gages; Vacuum GagesShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5636.02) 3/24/2026 Page 10 of 12
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Oscilloscopes3 (cont) –
AC Voltage –
Amplitude Vp-p –
(1 MΩ)
1 kHz
DC Voltage –
1 MΩ
50 Ω
1 mV to 200 Vp-p
1 mV to +/-200 V
1 mV to +/-5 V
l.0 % + 10 µV
0.025 % + 25 µV
0.025 % + 25 µV
Fluke 9500B / 9530
IV. Mechanical
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Scales & Balances3 –
Analytical Balances
Electronic Balances
(50 to 500) g
(50 to 2000) g
(4.4 x 10
4 + 3 x 10-6Wt) g
(1.2 x 10-2 + 1 x 10- 6Wt) g
Class 1 weights
Pressure Gages3
(0 to 6.89) kPa
(0 to 68.947) kPa
(0 to 1) psi
(0 to 10) psi
(0 to 2068) kPa
(0 to 6894) kPa
(0 to 34 473) kPa
(0 to 300) psi
(0 to 1000) psi
(0 to 5000) psi
0.024 kPa
0.093 kPa
0.0035 psi
0.014 psi
0.56 kPa
3.5 kPa
28 kPa
0.081 psi
0.5 psi
4 psi
Fluke 700P22
Druck DPI 610 w/
PDCR 2200-A145
Drunk DPI 611
Fluke 700P08
Fluke 700P30
Vacuum Gages3
(-755 to -2.5)
mmHg
(-29.72 to -0.098)
inHg
4.1 mmHg
0.16 inHg
Druck DPI 611 | - |
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5636.02) 3/24/2026 Page 11 of 12
Parameter/Equipment
Range
CMC2 (±)
Comments
Torque – Tools3
(0.28 to 2.8) N·m
(2.825 to 28.25) N·m
(33.9 to 339) N·m
(25 to 250) lbf·in
(25 to 250) lbf·ft
0.028 N·m
0.28 N·m
3.5 N·m
2.5 lbf·in
2.6 lbf·ft
AWS QCI-25
Mountz BMX250I
Mountz BMX250F
Mountz BMX250I
Mountz BMX250F
V. Thermodynamics
Parameter/Equipment
Range
CMC2, 8 (±)
Comments
Temperature – Measure3
(-20 to 0) °C
(0 to 420) °C
(420 to 670) °C
0.026 °C
0.046 °C
0.067 °C
Additel ADT282 w/
Accumac AMI 751
Temperature – IR
Measuring Equipment
3
(50 to 500) °C
2 °C
Fluke 9132
Relative Humidity –
Measure3 (Fixed Points)
11.3 % RH
75 % RH
97 % RH
1.3 % RH
1.5 % RH
2 % RH
Vaisala 19729HM
Vaisala 19731HM
Vaisala 19732HM
Relative Humidity –
Measuring Equipment3
(10 to 90) % RH
1.2 % RH
Vaisala HMI41 w/
HMP46
VI. Time & Frequency
Parameter/Equipment
Range
CMC2 (±)
Comments
Stopwatches & Timers3
(5 to 180) min
0.098 s
HP 53181A
Tachometers –
Mechanical3
(575 to 3500) rpm
0.4 rpm
Automation Direct
CCT-AN-A120 counter | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5636.02) 3/24/2026 Page 12 of 12
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Tachometers – Photo3
(60 to 100 000) rpm
1.2 rpm
Fluke 5500A
Oscilloscope – Time
Markers3 (1,2,2.5,4,5
Sequence)
900.91 ns to 83 µs
83 µs to 55 s
0.000 025 %
0.0003 %
Fluke 9500B/ 9530
__________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavi or of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., r esolution,
repeatability) must also be considered and this, on its own, could result in the actual measurement
uncertainty achievable on a customer’s site being larger than the CMC.
4 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent
or fraction of the reading plus a fixed floor specification.
5 L is the numerical value of the nominal length of the device measured in inches or millimeters,
6 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated.
7 Wt is the numerical value of the nominal mass of the device measured in grams.
8 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
9 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 13 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
2 other sites in this organization
Labs with overlapping accredited scope in United States
- Sapphire Technical Solutions, L.L.C.Pineville, NC · ~44 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Winston-SalemWinston-Salem, NC · ~88 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Aalberts IPSAPageland, SC · ~92 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - GreensboroGreensboro, NC · ~117 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- On Point CalibrationZionville, NC · ~124 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.