Freudenberg-NOK International Seal
2041 East Wilshire Avenue, 92705, Santa Ana, CA, United States
Visit website- Accredited standards
- 8
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 8 standard numbers and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.
ASTM D297
ASTM D395
ASTM D412
ASTM D471
ASTM D573
ASTM D1329
ASTM D1414Exclusion
Limits written next to it
Test Methods for Rubber O-Rings ASTM D1414 (All Methods Except 16.2.2, 17
ASTM D2240Standard Test Method for Rubber Property - Durometer Hardness
ASTM D297; ASTM D395; ASTM D1414; ASTM D412; ASTM D471; ASTM D573; ASTM D1329; ASTM D2240
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
2 lines
ISO/IEC 17025
Active822.01
The scope document we hold says it is valid until 2027-04-30.
Accredited scope, certificate 822.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASTM D297; ASTM D395; ASTM D1414; ASTM D412; ASTM D471; ASTM D573; ASTM D1329; ASTM D2240 | rubber o-rings | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
FREUDENBERG-NOK INTERNATIONAL SEAL
Santa Ana, CA
for technical competence in the field of
Mechanical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 19th day of March 2025.
__ _____________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 0822.01
Valid to April 30, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Mitutoyo America CorporationCity of Industry, CA · ~31 kmA2LAShares 1 accredited test methodASTM D2240
- Micro Quality CalibrationChatsworth, CA · ~88 kmA2LAShares 1 accredited test methodASTM D2240
- MGA Research CorporationHughson, CA · ~506 kmA2LAShares 1 accredited test methodASTM D2240
- International Process SolutionsSan Carlos, CA · ~576 kmA2LAShares 1 accredited test methodASTM D2240
- Technical Maintenance, Inc. - COLORADO SPRINGSColorado Springs, CO · ~1,297 kmA2LAShares 1 accredited test methodASTM D2240
Accreditation data refreshed from the A2LA register on .