MGA Research Corporation

2331 Tully Road, 95326, Hughson, CA, United States

Visit website
A2LA 850.06ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
8
A2LA certificate
1
Sites in our directory
11
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 8 standard numbers and the 3 official names we hold. When no standard matches, it searches the method text of every scope line.

AATCC 8
ASTM D523Standard Test Method for Specular Gloss
ASTM D624
ASTM D1308
ASTM D2240Standard Test Method for Rubber Property - Durometer Hardness
ASTM D3359
ISO 845Cellular plastics and rubbers - Determination of apparent density
VDA 270

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

5 lines
A2LA

ISO/IEC 17025

Active

850.06

The scope document we hold says it was valid until 2026-07-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 850.06

LineMethodMatrixRange
1ISO/IEC 17025:2017; FMVSS 201; ECE-17/21/25; GMW14412; FMVSS 201U; GM 9685P; ST-0047; PF-A0256; Euro-NCAP; UN R127; GTR No. 9; US-NCAP; UNR127; MIL-STD-202G, Method 213; MIL-STD-810 A-G, Procedure VII; GMW14497; PF-8401; GMW3172, GMW14124; PF-11365, PF-10952, PF-11029, PF-11084; Ford WSS-M15P4-F; MGATP_MT_Xenon; SAE J2412seating systems, instruments panels, glove boxes, storage doors, floor and overhead consoles, doors, door panels, windows, hoods, liftgates, decklids/trunks, swing metal components, roof systems, closure systems, structural components and other interior and exterior components for the automotive industry and other transportation- related industries including aerospace, rail, train, bus, and defenseSee scope document
2ASTM D523; ASTM D3359; ASTM D1308; GM 3402; FLTM BN 112-08; LP-463PB-31-01; AATCC TM8; SAE J861; GMW3235; LP-463DB-12-01; SAE J1756; SAE J1351; VDA 270; FLTM BO 131-03; GMW3205; PF 9590; GMW3172; GMW3431; GMW3118; GMW3112; GMW3115; PF-10827; AA-0013; GMW16418; SAE J2258; ST-0035; GMW14364; PF-10254-0.003 to 2000000000 Ω
3ISO 845; GMW3208; SAE J948; SAE J1530; ASTM D2240; FMVSS 302; ASTM D624 (Type T); D1000; D2261; D5034; D5035; D5587; GMW 3010; GMW 3326; WSS-M15P20-B1; MGATP_MT_SG; MGATP_MT_TAB; MGATP_MAT_SCRATCH; MGATP_MT_SHORE; MGATP_MT_HBURN; MGATP_MT_UTMC; MGATP_MT_UTMF; MGATP_MT_UTMT; MGATP_MT_PEEL; MGATP_MT_DMST; MGATP_MT_DENPlasticsto 700 mm
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 0850.06) Revised 09/15/2025 Page 4 of 4 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing routine calibrations of nearly ideal measurement standards of nearly ideal m easuring equipment. CMC’s represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 This test is not equivalent to that of a calibration. 4 This laboratory offers commercial dimensional testing service only.
5

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited MGA RESEARCH CORPORATION Hughson, CA for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 11th day of July 2024. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 0850.06 Valid to July 31, 2026 Revised September 15, 2025

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.