Centre Testing International Group Co.,
Building C, Hongwei Industrial Park, Block 70, Bao'an District, Shenzhen, Guangdong, 518101, People's Republic of China, Shenzhen, Guangdong, China
Visit website- Accredited standards
- 50
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 50 standard numbers and the 42 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC14
IEC 60204-1Safety of machinery - Electrical equipment of machines - Part 1: General requirements
IEC 60533
IEC 60945Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results
IEC 60950-1Information technology equipment - Safety - Part 1: General requirementsExclusion
Limits written next to it
IEC 60950-1 (excluding clauses: 2.10.8.4, 3.4.7, and 4.2.8
IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
IEC 61547Equipment for general lighting purposes - EMC immunity requirements
IEC 61851-21-2
IEC 62040-2Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements
IEC 62209-1
IEC 62209-2
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements
IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
IEC 80601-2-77
IEC 61000 series11
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection
IEC 61000-3-12Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity testExclusion
Limits written next to it
EN 61000-4-8 (excluding short duration mode)
IEC 61000-4-8 (excluding short duration mode)
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-13Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics including mains signalling at a.c. power port, low frequency immunity tests
IEC 61000-4-29Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
ISO 80601 series10
ISO 80601-2-12Medical electrical equipment - Part 2-12: Particular requirements for basic safety and essential performance of critical care ventilators
ISO 80601-2-13Medical electrical equipment - Part 2-13: Particular requirements for basic safety and essential performance of an anaesthetic workstation
ISO 80601-2-55Medical electrical equipment - Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitors
ISO 80601-2-56Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement
ISO 80601-2-61Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment
ISO 80601-2-69Medical electrical equipment - Part 2-69: Particular requirements for the basic safety and essential performance of oxygen concentrator equipment
ISO 80601-2-70Medical electrical equipment - Part 2-70: Particular requirements for basic safety and essential performance of sleep apnoea breathing therapy equipment
ISO 80601-2-72Medical electrical equipment - Part 2-72: Particular requirements for basic safety and essential performance of home healthcare environment ventilators for ventilator-dependent patients
ISO 80601-2-74Medical electrical equipment - Part 2-74: Particular requirements for basic safety and essential performance of respiratory humidifying equipment
ISO 80601-2-79Medical electrical equipment - Part 2-79: Particular requirements for basic safety and essential performance of ventilatory support equipment for ventilatory impairment
ISO5
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 13766-2Earth-moving and building construction machinery - Electromagnetic compatibility (EMC) of machines with internal electrical power supply - Part 2: Additional EMC requirements for functional safety
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
ISO 11452 series4
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fields
ISO 11452-9Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 9: Portable transmitters
IEC 60601 series3
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 60601-2-16
IEC 60601-2-57
Other standards3
ANSI C63
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
ISO 80601-2-12; ISO 80601-2-13; IEC 62368-1; IEC 60950-1; IEC 60204-1
ISO 13766-2; IEC 60533; IEC 60945; IEC 61851-21-2; IEC 62040-2
ISO 80601-2-12 Second edition 2020-02 1-146 ISO 80601-2-13 First edition 2011-08-11 1-141 ISO 80601-2-13 Second Edition 2022-04 1-165 IEC 60601-2-16 Edition 5; ISO 80601-2-55 Second edition 2018-02 1-140 ISO 80601-2-56 Second Edition 2017-03 6-421 IEC 60601-2-57 Edition 1; ISO 80601-2-61 Second Edition 2017-12; IEC 61010-1; IEC 60601-1-2
ISO 7637-2; ISO 7637-3; ISO 10605; ISO 11452-2; ISO 11452-4 Immunity to Magnetic Fields ISO 11452-8 Portable Transmitters ISO 11452-9 Electrical Loads ISO 16750-2 Product EMC Standards IEC 61547
IEC 62209-2; IEC 62209-1; IEC 62479; IEC 62311; IEEE 62209-1528
ISO 80601-2-69 Second Edition 2020-11 1-148 ISO 80601-2-70 Second Edition 2020-11 1-151 ISO 80601-2-72 First edition 2015-04-11 1-105 ISO 80601-2-72 Second Edition 2023-06 1-163 ISO 80601-2-74 First edition 2017-05 1-138 ISO 80601-2-74 Second Edition 2021-07 1-177 IEC 80601-2-77 Edition 1; ISO 80601-2-79 First Edition 2018-07 1-143 IEC TR 60601-4-2 Edition 1; IEC 80601-2-77
IEC 55014-1; IEC 55015; IEC 61000-6-3; IEC 61000-6-4; IEC 61000-3-2
IEC 61000-3-2; IEC 61000-3-12; IEC 61000-3-3; IEC 61000-3-11; IEC 61000-4-2
ISO 7637-2; ISO 7637-3 Harmonics and Interharmonics IEC 61000-4-13; IEC 61000-4-8; IEC 61000-4-11; IEC 61000-4-29
ISO 80601-2-55; ISO 80601-2-56; ISO 80601-2-61; ISO 80601-2-69; ISO 80601-2-70
ANSI C63; ANSI/TIA-603; ANSI/TIA-603-E-2016
Read from the A2LA scope document we downloaded on 2025-12-02. Register refreshed 2026-11-20.
Scope as published by A2LA
12 lines
ISO/IEC 17025
Active3061.01
The scope document we hold says it is valid until 2026-11-30.
Labs with overlapping accredited scope in China
- BTL Inc. (Dongguan)Dongguan, GuangdongA2LAShares 4 accredited test methodsANSI C63IEC 55014-1IEC 62368-1
- Bureau Veritas Shenzhen Co., Ltd. Dongguan BranchDongguan City, Guangdong ProvinceA2LAShares 4 accredited test methodsANSI C63IEC 55014-1IEC 61000-3-2
- Attestation of Global Compliance (Shenzhen) Co.,GuangdongA2LAShares 3 accredited test methodsANSI C63IEC 61000-3-2IEC 62368-1
- BTF Testing Lab (Shenzhen) Co.,Shenzhen, GuangdongA2LAShares 3 accredited test methodsANSI C63IEC 55014-1IEC 62479
- BTL Inc. (Shanghai)ShanghaiA2LAShares 3 accredited test methodsANSI C63IEC 55014-1IEC 62479
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.