Laboratorium Pomiarów Środowiska Pracy LUX-MODUS dr Katarzyna Balicka, mgr inż Piotr Balicki S.C.

ul. Barkowska 9e, 43-300, Bielsko-Biała, Poland

PCA|AB 1654ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
4
Standards
5
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Laboratorium Pomiarów Środowiska Pracy LUX-MODUS dr Katarzyna Balicka, mgr inż Piotr Balicki S.C.?

Claim this profile to keep it accurate.

Register record

PCARefreshed
AB 1654Active

Accredited standards

5

Our reading of the PCA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

EN 14253Mechanical vibration - Measurement and evaluation of occupational exposure to whole-body vibration with reference to health - Practical guidanceCertificate says EN 14253+A1:2011. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 4 (PCA AB 1654)

PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11; PN-EN 14253+A1:2011

ISO 5349-1Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 1: General requirements
As written on the certificate · Line 4 (PCA AB 1654)

PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11; PN-EN 14253+A1:2011

ISO 5349-2Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 2: Practical guidance for measurement at the workplace
As written on the certificate · Line 4 (PCA AB 1654)

PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11; PN-EN 14253+A1:2011

ISO 9612Acoustics - Determination of occupational noise exposure - Methodology
As written on the certificate · Line 3 (PCA AB 1654)

PN-N-01307:1994; PN-ISO 9612:2011; PN-83/E-04040.03; Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)

PN-N-01307:1994Hałas - Dopuszczalne wartości hałasu w środowisku pracy - Wymagania dotyczące wykonywania pomiarów
As written on the certificate · Line 3 (PCA AB 1654)

PN-N-01307:1994; PN-ISO 9612:2011; PN-83/E-04040.03; Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)

Scope as published by PCA

4 lines
PCA

ISO/IEC 17025

Active

AB 1654

The scope document we hold says it is valid until 2029-07-10.

View on PCA

Accredited scope, certificate AB 1654

LineDisciplineMethodMatrixRange
1environmental-working environment (harmful and nuisance factors noise, vibration, lighting), general environment (physical factors – noise); working environment (harmful factors – air)-
2environmentalPN-Z-04008-7:2002 + Az1:2004; PN-Z-04507:2022-05+Ap1:2022-08; PN-Z-04508:2022-05+Ap1:2022-08Ambient air0.08 to 34 mg/m3
3environmentalPN-N-01307:1994; PN-ISO 9612:2011; PN-83/E-04040.03; Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)Workplace environment5 to 10000 lx; dB
4environmentalPN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11; PN-EN 14253+A1:2011Workplace environment0.6 to 1130 m/s2

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

ul. Barkowska 9e, Bielsko-Biała, 43-300, PL

49.82212, 19.04489

Open in Maps

Accreditation data refreshed from the PCA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.