What this lab is accredited for
Our reading of the SWEDAC scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 24 standard numbers and the 18 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM12
ASTM A262Standard Practices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels
ASTM A370Standard Test Methods and Definitions for Mechanical Testing of Steel Products
ASTM A923Standard Test Methods for Detecting Detrimental Intermetallic Phase in Duplex Austenitic/Ferritic Stainless Steels
ASTM A1084
ASTM E21Standard Test Methods for Elevated Temperature Tension Tests of Metallic Materials
ASTM E23Standard Test Methods for Notched Bar Impact Testing of Metallic Materials
ASTM E45Standard Test Methods for Determining the Inclusion Content of Steel
ASTM E92Standard Test Methods for Vickers Hardness and Knoop Hardness of Metallic Materials
ASTM E112Standard Test Methods for Determining Average Grain Size
ASTM E562Standard Test Method for Determining Volume Fraction by Systematic Manual Point Count
ASTM G28
ASTM G48Standard Test Methods for Pitting and Crevice Corrosion Resistance of Stainless Steels and Related Alloys by Use of Ferric Chloride Solution
ISO8
ISO 148-1Metallic materials - Charpy pendulum impact test - Part 1: Test method
ISO 3651-1Determination of resistance to intergranular corrosion of stainless steels - Part 1: Austenitic and ferritic-austenitic (duplex) stainless steels - Corrosion test in nitric acid medium by measurement of loss in mass (Huey test)
ISO 3651-2Determination of resistance to intergranular corrosion of stainless steels - Part 2: Ferritic,austenitic and ferritic-austenitic (duplex) stainless steels - Corrosion test in media containing sulfuric acid
ISO 6506-1Metallic materials - Brinell hardness test - Part 1: Test method
ISO 6507-1Metallic materials - Vickers hardness test - Part 1: Test method
ISO 6508-1Metallic materials - Rockwell hardness test - Part 1: Test method
ISO 6892-1Metallic materials - Tensile testing - Part 1: Method of test at room temperature
ISO 6892-2Metallic materials - Tensile testing - Part 2: Method of test at elevated temperature
EN3
EN 10002-1
EN 10002-5
EN 10045-1
Other standards1
DIN 50106
ASTM A1084; ASTM A923; ASTM A262; EN ISO 3651-1; Engineering Standard 8-A10S; Stamicarbon 53961; UREA CASALE 8000-00-MSM-001; ASTM G48; EN ISO 3651-2; ASTM G28; ASTM E45; ASTM E562; ASTM A923; ASTM A262; Intern metod; PRM-0644; Intern metod; PRM-1533
ASTM A370; ASTM E21; SS-EN 10002-1; SS-EN 10002-5; SS-EN ISO 6892-1; SS-EN ISO 6892-2; ASTM E92; SS-EN ISO 6506-1; SS-EN ISO 6507-1; SS-EN ISO 6508-1; ASTM A1084; ASTM A370; ASTM A923; ASTM E23; SS-EN 10045-1; SS-EN ISO 148-1; DIN 50106; SS-EN ISO/IEC 17025:2018
ASTM E112; Intern metod; PRM-0639; Intern metod; PRM-0640
Read from the scope as published by SWEDAC. Register refreshed 2026-11-08.
Scope as published by SWEDAC
6 lines
ISO/IEC 17025
WithdrawnA000354-003
Accredited scope, certificate A000354-003
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASTM A370; ASTM E21; SS-EN 10002-1; SS-EN 10002-5; SS-EN ISO 6892-1; SS-EN ISO 6892-2; ASTM E92; SS-EN ISO 6506-1; SS-EN ISO 6507-1; SS-EN ISO 6508-1; ASTM A1084; ASTM A370; ASTM A923; ASTM E23; SS-EN 10045-1; SS-EN ISO 148-1; DIN 50106; SS-EN ISO/IEC 17025:2018 | Metal | - |
| 2 | ASTM A1084; ASTM A923; ASTM A262; EN ISO 3651-1; Engineering Standard 8-A10S; Stamicarbon 53961; UREA CASALE 8000-00-MSM-001; ASTM G48; EN ISO 3651-2; ASTM G28; ASTM E45; ASTM E562; ASTM A923; ASTM A262; Intern metod; PRM-0644; Intern metod; PRM-1533 | Metal | - |
| 3 | ASTM E112; Intern metod; PRM-0639; Intern metod; PRM-0640 | Metalliska material; Metalliska material; Metalliska material | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveA015869-001
Accredited scope, certificate A015869-001
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASTM A370; ASTM E21; SS-EN 10002-1; SS-EN 10002-5; SS-EN ISO 6892-1; SS-EN ISO 6892-2; ASTM E92; SS-EN ISO 6506-1; SS-EN ISO 6507-1; SS-EN ISO 6508-1; ASTM A1084; ASTM A370; ASTM A923; ASTM E23; SS-EN 10045-1; SS-EN ISO 148-1; DIN 50106; SS-EN ISO/IEC 17025:2018 | Metal | - |
| 2 | ASTM A1084; ASTM A923; ASTM A262; EN ISO 3651-1; Engineering Standard 8-A10S; Stamicarbon 53961; UREA CASALE 8000-00-MSM-001; ASTM G48; EN ISO 3651-2; ASTM G28; ASTM E45; ASTM E562; ASTM A923; ASTM A262; Intern metod; PRM-0644; Intern metod; PRM-1533 | Metal | - |
| 3 | ASTM E112; Intern metod; PRM-0639; Intern metod; PRM-0640 | Metalliska material; Metalliska material; Metalliska material | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in Sweden
- Element Materials TechnologyKarlskoga · ~12 kmSWEDACShares 3 accredited methods and materialsASTM A370ASTM E112Metal
- Alleima TubeSandviken · ~202 kmSWEDACShares 2 accredited materialsMetalSteel
- Safe Control MaterialteknikGöteborg · ~223 kmSWEDACShares 2 accredited methods and materialsASTM E112Metal
- Kiwa SwedenÖrebro · ~44 kmSWEDACShares 1 accredited materialMetal
- Kiwa SwedenKarlstad · ~57 kmSWEDACShares 1 accredited materialMetal
Accreditation data refreshed from the SWEDAC register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the SWEDAC entry linked above.