Progetto Ambiente & C. S.a.s. di Danilo Pulvirenti
Via Alberto Mario 2, 95129, Catania, Italy
Visit website- Accredited standards
- 11
- ACCREDIA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 11 standard numbers and the 8 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO5
ISO 5667-5Water quality - Sampling - Part 5: Guidance on sampling of drinking water from treatment works and piped distribution systems
ISO 10523Water quality - Determination of pH
ISO 19458Water quality - Sampling for microbiological analysis
ISO 22036Environmental solid matrices - Determination of elements using inductively coupled plasma optical emission spectrometry (ICP-OES)
ISO 54321Soil, treated biowaste, sludge and waste - Digestion of aqua regia soluble fractions of elements
EN3
EN 12457-2Characterisation of waste - Leaching - Compliance test for leaching of granular waste materials and sludges - Part 2: One stage batch test at a liquid to solid ratio of 10 l/kg for materials with particle size below 4 mm (without or with size reduction)
EN 15934Sludge, treated biowaste, soil and waste - Calculation of dry matter fraction after determination of dry residue or water content
EN 16192
Other standards3
APAT CNR IRSA 2050 Man 29 2003
APAT CNR IRSA 4020 Man 29 2003
EPA 6010Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES)
ISO 5667-5:2006; UNI EN ISO 19458:2006
APAT CNR IRSA 4020 Man 29 2003; APAT CNR IRSA 2020 A Man 29 2003; APAT CNR IRSA 2110 Man 29 2003; APAT CNR IRSA 3030 Man 29 2003; UNI EN ISO 10523:2012; Rapporti ISTISAN 2007/31 pag 126 Met ISS CBB006; Rapporti ISTISAN 2007/31 pag 164 Met ISS CAA036; APAT CNR IRSA 2060 Man 29 2003
EPA 6010D 2018; ANPA 15 Man 3 2001; ANPA 8 Man 3 2001; UNI EN 15934:2012; CNR IRSA 1 Q 64 Vol 3 1985 + APAT CNR IRSA 2060 Man 29 2003; UNI EN 12457-2:2004, APAT CNR IRSA 4020 Man 29 2003; UNI EN 12457-2:2004, UNI EN 16192:2012, APAT CNR IRSA 2030 Man 29 2003; UNI EN 12457-2:2004, UNI EN 16192:2012, APAT CNR IRSA 2060 Man 29 2003; UNI EN ISO 54321:2021 Met B + UNI EN ISO 22036:2024; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met II.1
UNI CEI EN ISO/IEC 17025:2018; APAT CNR IRSA 2050 Man 29 2003; APAT CNR IRSA 2090 A Man 29 2003; APAT CNR IRSA 2080 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; Rapporti ISTISAN 2007/31 pag 179; Met ISS CAA004; APAT CNR IRSA 5080 Man 29 2003; HRGC-LRMS; APAT CNR IRSA 5060 Man 29 2003
Read from the scope as published by ACCREDIA. Register refreshed 2026-11-20.
Scope as published by ACCREDIA
4 lines
ISO/IEC 17025
Active01263
Accredited scope, certificate 01263
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | UNI CEI EN ISO/IEC 17025:2018; APAT CNR IRSA 2050 Man 29 2003; APAT CNR IRSA 2090 A Man 29 2003; APAT CNR IRSA 2080 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; Rapporti ISTISAN 2007/31 pag 179; Met ISS CAA004; APAT CNR IRSA 5080 Man 29 2003; HRGC-LRMS; APAT CNR IRSA 5060 Man 29 2003 | Waste water | - |
| 2 | APAT CNR IRSA 4020 Man 29 2003; APAT CNR IRSA 2020 A Man 29 2003; APAT CNR IRSA 2110 Man 29 2003; APAT CNR IRSA 3030 Man 29 2003; UNI EN ISO 10523:2012; Rapporti ISTISAN 2007/31 pag 126 Met ISS CBB006; Rapporti ISTISAN 2007/31 pag 164 Met ISS CAA036; APAT CNR IRSA 2060 Man 29 2003 | Drinking water | - |
| 3 | EPA 6010D 2018; ANPA 15 Man 3 2001; ANPA 8 Man 3 2001; UNI EN 15934:2012; CNR IRSA 1 Q 64 Vol 3 1985 + APAT CNR IRSA 2060 Man 29 2003; UNI EN 12457-2:2004, APAT CNR IRSA 4020 Man 29 2003; UNI EN 12457-2:2004, UNI EN 16192:2012, APAT CNR IRSA 2030 Man 29 2003; UNI EN 12457-2:2004, UNI EN 16192:2012, APAT CNR IRSA 2060 Man 29 2003; UNI EN ISO 54321:2021 Met B + UNI EN ISO 22036:2024; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met II.1 | Soil | - |
| 4 | ISO 5667-5:2006; UNI EN ISO 19458:2006 | Acque destinate al consumo umano da impianti di trattamento e da sistemi di distribuzione convogliato/Drinking waters from treatment works and piped distribution systems; Acque destinate al consumo umano/Drinking waters, Acque di piscina/Swimming pool waters, Acque naturali/Natural waters | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Italy
- SIALAB (Avola)Avola · ~67 kmACCREDIAShares 4 accredited methods and materialsEPA 6010D 2018Drinking waterSoil
- Capone Lab s.r.l.Milazzo · ~77 kmACCREDIAShares 4 accredited methods and materialsAPAT CNR IRSA 4020 Man 29 2003Drinking waterSoil
- TETRALABPace del Mela - Giammoro · ~79 kmACCREDIAShares 4 accredited methods and materialsAPAT CNR IRSA 4020 Man 29 2003Drinking waterSoil
- AmbienteMessina · ~96 kmACCREDIAShares 4 accredited methods and materialsAPAT CNR IRSA 2050 Man 29 2003Drinking waterSoil
- S.I.G.R.A.Taurianova · ~123 kmACCREDIAShares 4 accredited methods and materialsAPAT CNR IRSA 2050 Man 29 2003APAT CNR IRSA 4020 Man 29 2003ISO 5667-5:2006
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.