Capone Lab s.r.l.
Via delle Gelsominaie, 31/33, 98057, Milazzo, Italy
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Capone Lab s.r.l.?
Claim this profile to keep it accurate.
Register record
- ACCREDIARefreshed
- 01233Active
Certificates and scope
1ISO/IEC 17025
Active01233
Accredited scope, certificate 01233
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | biological | ISO 11731:2017; UNI EN ISO 11731:2017; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; APAT CNR IRSA 2080 Man 29 2003; APAT CNR IRSA 4080 Man 29 2003; APAT CNR IRSA 2050 Man 29 2003; Rapporti ISTISAN 2007/31 pag 36 Met ISS BHE019; APAT CNR IRSA 2110 Man 29 2003; UNI EN ISO 9308-1:2017; UNI EN ISO 7899-2:2003 | Drinking water | - |
| 2 | chemical | UNI CEI EN ISO/IEC 17025:2018; APAT CNR IRSA 4020 Man 29 2003; UNI EN ISO 11885:2009; UNI EN ISO 14189:2016; APAT CNR IRSA 2020 A Man 29 2003; UNI EN ISO 17294-2:2023; UNI EN 1484:1999; DM 23/03/2000 SO n 60 GU n 87 13/04/2000 All 1 pag 31; APAT CNR IRSA 7030 E Man 29 2003 | Drinking water | - |
| 3 | chemical; biological | UNI ISO 16649-2:2010; UNI EN ISO 21528-2:2017/EC 1:2018; UNI EN ISO 4833-1:2022; UNI EN ISO 6888-2:2023; MI CAPONE 01 rev.00 2024; UNI EN 13657:2004 par 6.1; UNI EN ISO 22036:2024; UNI EN 15934:2012; UNI EN 15936:2022; UNI EN 12457-2:2004; UNI EN ISO 11885:2009; UNI EN 12457-2:2004, APAT CNR IRSA 4020 Man 29 2003; UNI EN 12457-2:2004, APAT CNR IRSA 2030 Man 29 2003; UNI EN 12457-2:2004, APAT CNR IRSA 2060 Man 29 2003; UNI EN 14039:2005 | Food industry environment samples | 20 to 50 % |
| 4 | - | UNI CEI EN ISO/IEC 17025:2018; EPA 3546 2007; EPA 8270E 2018; UNI EN ISO 18593:2018; UNI ISO 16649-2:2010; ISO 21527-2:2008; DM 21/03/2005 GU n 79 06/04/2005 Met I.2 | Soil | - |
| 5 | chemical | APAT CNR IRSA 2100 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; UNI 10802:2023 | Waste water | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Italy
- NATURA S.r.l.Casoria · ~312 kmACCREDIAShares 6 accredited methods and materialsAPAT CNR IRSA 2100 Man 29 2003EPA 8270E 2018Drinking water
- ECOCONTROLPomezia · ~448 kmACCREDIAShares 6 accredited methods and materialsAPAT CNR IRSA 2100 Man 29 2003EN ISO 11731:2017Drinking water
- C.I.A. LAB S.R.L.Ascoli Piceno · ~540 kmACCREDIAShares 6 accredited methods and materialsEN ISO 11731:2017ISO 16649-2:2010Drinking water
- TECNO PIEMONTELenta · ~995 kmACCREDIAShares 6 accredited methods and materialsEN ISO 11731:2017EPA 8270E 2018Drinking water
- TETRALABPace del Mela - Giammoro · ~5 kmACCREDIAShares 5 accredited methods and materialsAPAT CNR IRSA 4020 Man 29 2003Drinking waterFood industry environment samples
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.