Registers refreshed 2026-11-20.See refresh dates
Germany

S-TEAM ELEKTRONIK

Schleifweg 2, 74257, Untereisesheim, Germany

Visit website
DAKKS D-PL-12034-01-00DAKKS D-PL-12034-01-01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
53
DAKKS certificates
2
Site in our directory
1
DAKKS accredited scope

What this lab is accredited for

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 53 standard numbers and the 40 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 61000 series14
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection

Certificate says EN 61000-3-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-29Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments

Certificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
ISO8
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 13766-1Earth-moving and building construction machinery - Electromagnetic compatibility (EMC) of machines with internal electrical power supply - Part 1: General EMC requirements under typical electromagnetic environmental conditions
ISO 13766-2Earth-moving and building construction machinery - Electromagnetic compatibility (EMC) of machines with internal electrical power supply - Part 2: Additional EMC requirements for functional safety
ISO 14982Agricultural and forestry machinery - Electromagnetic compatibility - Test methods and acceptance criteria
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
ISO 20076Road vehicles - Test methods and performance requirements for voltage class B connectors
CISPR7
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

CISPR 12Vehicles, boats and devices with internal combustion engines or traction batteries - Radio disturbance characteristics - Limits and methods of measurement for the protection of off-board receivers

Certificate says EN 55012. Probably the same standard; not checked against the EN document.

CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission

Certificate says IEC 55014-1. Probably the same standard; not checked against the EN document.

CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard

Certificate says IEC 55014-2. Probably the same standard; not checked against the EN document.

CISPR 25Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers

Certificate says EN 55025. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements

Certificate says EN 55035. Probably the same standard; not checked against the EN document.

EN5
EN 12895
EN 13309
EN 50155Railway applications - Rolling stock - Electronic equipment
EN 50289-1-6
EN 50289-1-11
IEC 61326 series5
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications
IEC 61326-2-2Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems
IEC 61326-3-1
IEC 61326-3-2
IEC 62153 series5
IEC 62153-4-3
IEC 62153-4-4
IEC 62153-4-7
IEC 62153-4-9
IEC 62153-4-15
ISO 11452 series5
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
ISO 11452-5Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 5: Stripline
ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fields
ISO 11452-9Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 9: Portable transmitters
EN 50121 series3
EN 50121-2
EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
Other standards1
IEC 60947-5-3

Read from the scope as published by DAKKS. Register refreshed 2026-11-20.

Scope as published by DAKKS

26 lines
DAKKS

ISO/IEC 17025

Active

D-PL-12034-01-00

View scope
DAKKS

ISO/IEC 17025

Active

D-PL-12034-01-01

View scope

Location

Schleifweg 2, Untereisesheim, 74257, DE

49.20654, 9.20389

Open in Maps

Accreditation data refreshed from the DAKKS register on .