Cascade Engineering - Analytical

4855 37th Street SE, 49512, Grand Rapids, MI, United States

Visit website
A2LA 2263.02ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
10
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 10 standard numbers and the 4 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM D523Standard Test Method for Specular GlossExclusion

Limits written next to it

Specular Gloss ASTM D523 (except 85O)

Exclusion. Written next to it on line 2 of A2LA certificate 2263.02.

ASTM D618
ASTM D624
ASTM D790Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials
ASTM D792Standard Test Methods for Density and Specific Gravity (Relative Density) of Plastics by Displacement
ASTM D955
ASTM D1238
ASTM D2240Standard Test Method for Rubber Property - Durometer Hardness
ASTM D5630
ASTM E1421

Read from the A2LA scope document we downloaded on 2025-12-02. Register refreshed 2026-11-06.

Scope as published by A2LA

3 lines
A2LA

ISO/IEC 17025

Active

2263.02

The scope document we hold says it is valid until 2026-11-30.

View scope

Accredited scope, certificate 2263.02

LineMethodMatrixRange
1ASTM D5630; ASTM D618; ASTM D792; ASTM D2240; ASTM D790Plastics-
2ASTM D1238; ASTM D955; ASTM E1421; ASTM D523; ASTM D624--
3ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.