Eurofins SF Analytical - GMP Microbiology
215 Witmer Road, 19044, Horsham, PA, United States
Visit website- Accredited standards
- 13
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 13 standard numbers and the 4 official names we hold. When no standard matches, it searches the method text of every scope line.
USP8
USP 51
USP 60
USP 61
USP 62
USP 643
USP 1231
USP 2021
USP 2022
ISO4
ISO 6579-1Microbiology of the food chain - Horizontal method for the detection, enumeration and serotyping of Salmonella - Part 1: Detection of Salmonella spp.
ISO 7932Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of presumptive Bacillus cereus - Colony-count technique at 30 degrees C
ISO 11290-1Microbiology of the food chain - Horizontal method for the detection and enumeration of Listeria monocytogenes and of Listeria spp. - Part 1: Detection method
ISO 22964Microbiology of the food chain - Horizontal method for the detection of Cronobacter spp.
Other standards1
AOAC 991.14
USP <51>; USP <643>; USP <61>; USP <1231>; USP <62>; USP <60>
SMEDP 8.090 (modified); ISO 7932; FDA BAM Chpt 12; AFNOR 3M 01/16-11/16; ISO 6579-1; AFNOR 3M 01/20-03/18; ISO 22964; AFNOR 3M 01/14-05/16; ISO 11290-1; AFNOR 3M 01/15-09/16; ISO 11290-1; AFNOR 3M 01/0-09/89; AOAC 991.14 (modified); AFNOR 3M 01/13-07/14; AFNOR 3M 01/06-09/97; USP 2021; USP 2022
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active6174.01
The scope document we hold says it is valid until 2027-03-31.
Accredited scope, certificate 6174.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | USP <51>; USP <643>; USP <61>; USP <1231>; USP <62>; USP <60> | Infant formula | - |
| 2 | SMEDP 8.090 (modified); ISO 7932; FDA BAM Chpt 12; AFNOR 3M 01/16-11/16; ISO 6579-1; AFNOR 3M 01/20-03/18; ISO 22964; AFNOR 3M 01/14-05/16; ISO 11290-1; AFNOR 3M 01/15-09/16; ISO 11290-1; AFNOR 3M 01/0-09/89; AOAC 991.14 (modified); AFNOR 3M 01/13-07/14; AFNOR 3M 01/06-09/97; USP 2021; USP 2022 | Infant formula | - |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Biological Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
EUROFINS SF ANALYTICAL – GMP MICROBIOLOGY
Horsham, PA
for technical competence in the field of
Biological Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 21st day of April 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 6174.01
Valid to March 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
Accreditation data refreshed from the A2LA register on .