Umweltanalytik Saalfeld
Saalfelder Straße 35, 07338, Leutenberg, Germany
Visit website- Accredited standards
- 17
- DAKKS certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 17 standard numbers and the 15 official names we hold. When no standard matches, it searches the method text of every scope line.
EN15
EN 1911Stationary source emissions - Determination of mass concentration of gaseous chlorides expressed as HCl - Standard reference method
EN 1948-1Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Part 1: Sampling of PCDDs/PCDFs
EN 12619Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
EN 13211Air quality - Stationary source emissions - Manual method of determination of the concentration of total mercury
EN 13284-1Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method
EN 14181Stationary source emissions - Quality assurance of automated measuring systems
EN 14385Stationary source emissions - Determination of the total emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl and V
EN 14789Stationary source emissions - Determination of volume concentration of oxygen - Standard reference method: Paramagnetism
EN 14790Stationary source emissions - Determination of the water vapour in ducts - Standard reference method
EN 14791Stationary source emissions - Determination of mass concentration of sulphur oxides - Standard reference method
EN 14792Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: Chemiluminescence
EN 15058Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry
EN 15259Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report
EN 16911-1
EN 16911-2
Other standards2
ISO 17852Water quality - Determination of mercury - Method using atomic fluorescence spectrometry
ISO 21877Stationary source emissions— Determination of the mass concentration of ammonia - Manual method
VDI 4220; DIN EN 15259:2008; DIN EN 14790:2017-05; DIN EN 14789:2017-05; DIN EN 13284-1:2018-02; DIN EN 14385:2004-05; DIN EN 13211:2001-06; DIN EN ISO 17852:2008-04; DIN EN 14792:2017-05; DIN EN 15058:2017-05; DIN EN 14791:2017-05; DIN EN 1911:2010-12; DIN EN 12619:2013-04; VDI 3862 Blatt 4:2001-05
DIN EN ISO 21877:2020-01; DIN CEN TS 13649:2015-03; VDI 2470 Blatt 1:1975; DIN EN 1948-1:2006-06; DIN EN 16911-1:2013-06; DIN EN 16911-2:2013-06; DIN EN 14789:2017-05; DIN EN 14790:2017-05; DIN EN 14181:2015-02; VDI 3950-1 Blatt 1:2018-06
DIN EN 14181:2015-02; VDI 3950-1 Blatt 1:2018-06
Read from the scope as published by DAKKS. Register refreshed 2026-11-20.
Scope as published by DAKKS
4 lines
ISO/IEC 17025
ActiveD-PL-22416-01-00
Accredited scope, certificate D-PL-22416-01-00
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001 | Luftinhaltsstoffe | - |
| 2 | VDI 4220; DIN EN 15259:2008; DIN EN 14790:2017-05; DIN EN 14789:2017-05; DIN EN 13284-1:2018-02; DIN EN 14385:2004-05; DIN EN 13211:2001-06; DIN EN ISO 17852:2008-04; DIN EN 14792:2017-05; DIN EN 15058:2017-05; DIN EN 14791:2017-05; DIN EN 1911:2010-12; DIN EN 12619:2013-04; VDI 3862 Blatt 4:2001-05 | Emissionen (Luft) | - |
| 3 | DIN EN ISO 21877:2020-01; DIN CEN TS 13649:2015-03; VDI 2470 Blatt 1:1975; DIN EN 1948-1:2006-06; DIN EN 16911-1:2013-06; DIN EN 16911-2:2013-06; DIN EN 14789:2017-05; DIN EN 14790:2017-05; DIN EN 14181:2015-02; VDI 3950-1 Blatt 1:2018-06 | Air | - |
| 4 | DIN EN 14181:2015-02; VDI 3950-1 Blatt 1:2018-06 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Germany
- GWA Gesellschaft für Wasser- und Abwasserservice mbH Institut für Wasser- und UmweltanalytikLuisenthal · ~55 kmDAKKSShares 2 accredited methods and materialsEN ISO 9001Air
- CLG Chemisches Labor Dr. Graser KGSchonungen · ~100 kmDAKKSShares 2 accredited methods and materialsEN ISO 9001Air
- Institut Dr. Nuss GmbH & Co. KGBad Kissingen · ~106 kmDAKKSShares 2 accredited methods and materialsEN ISO 9001Air
- Eurofins Food & Feed Testing LeipzigLeipzig · ~111 kmDAKKSShares 2 accredited methods and materialsEN ISO 9001Air
- Analytik AurachtalAurachtal · ~119 kmDAKKSShares 2 accredited methods and materialsEN ISO 9001Air
Accreditation data refreshed from the DAKKS register on .