- A2LARefreshed
- 1711.01Active
Certificates and scope
1ISO/IEC 17025
Active1711.01
The scope document we hold says it is valid until 2027-01-31.
Accredited scope, certificate 1711.01
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | electrical | BCIS-04; BCIS-06; BCIS-15; SAE J537; SAE J240; SAE J2185; SAE J2801; SAE J930; EN 50342-1 | Battery | - |
| 2 | mechanical | EN 50342-1; JIS D5301; JIS D5302; JIS C8702; GMW 3092 | - | - |
| 3 | mechanical | GMW 3092; TSC5102G; ES-F4SF-10655-AB; PF-8568; 24410NDS00; IEC 60095-1 | - | - |
| 4 | mechanical | BCIS-04, 9.0; SAE J3060; EN 50342-1, 5.8; JIS D5301, 10.6; IEC 60095-1, 9.8 | - | -40 to 167 °F; °C; G’s; Hz; amps; volts |
| 5 | electrical | - | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.