Greenslade &
2234 Wenneca Ave., 76102, Fort Worth, TX, United States
Visit website- Accredited standards
- 1
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 1 standard number and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.
ASTM E18Standard Test Methods for Rockwell Hardness of Metallic Materials
ASTM E18
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-10-23.
Scope as published by A2LA
7 lines
ISO/IEC 17025
Active1032.01
The scope document we hold says it was valid until 2026-10-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.
Accredited scope, certificate 1032.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/ASME B1.2 | - | See scope document |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1032.01) Revised 12/03/2024 Page 2 of 6
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Thread Plugs –
Major Diameter
Pitch Diameter
Flank Angle
(0.06 to 10) in
(0.06 to 10) in
Up to 60°
26 µin
80 µin
6.2'
UMM, best wire
method, microscope,
optical comparator
Specialty Gaging
Length
Radius
Angle
Up to 2 in
(2 to 8) in
Up to 0.5 in
Up to 90°
0.0001 in
0.0008 in
0.0001 in
6.2'
Measuring
microscope, optical
comparator, UMM
Thread Measuring Wires
– 60° Sets
(2 to 120) pitch
18 µin
UMM
Digital & Dial Indicators3
Up to 2 in
(34 + 14L) µin
Gage blocks
Calipers3
Parallelism
Up to 60 in
Up to 60 in
(380 + 11L) µin
46 µin
Gage blocks
Micrometers3
Parallelism
Up to 6 in
(6 to 24) in
Up to 24 in
(51 + 9.7L) µin
(22 + 15L) µin
46 µin
Gage blocks
Gage Pins & Plugs
Up to 1 in
(> 1 to 5) in
22 µin
62 µin
UMM
Optical Comparators3 –
Length
Radius
Angle
Up to 2 in
Up to 0.5 in
Up to 90°
0.000 14 in
0.000 14 in
3.5’
Glass scale, Gage
ball, Precision angle
blocks
Height Gages3
Up to 18 in
(18 to 48) in
(290 + 0.69L) µin
(160 + 3.2L) µin
Gage blocks with
surface plate | to 10 in |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1032.01) Revised 12/03/2024 Page 3 of 6
Parameter/Equipment
Range
CMC2, 4, 8 (±)
Comments
NPT Rings & Plug Gages
– Fixed Points
0.0625 (27 TPI)
0.125 (27 TPI)
0.25 (18 TPI)
0.375 (18 TPI)
0.5 (14 TPI)
0.75 (14 TPI)
1 (11.5 TPI)
1.25 (11.5 TPI)
1.5 (11.5 TPI)
2 (11.5 TPI)
3 (8 TPI)
920 µin
920 µin
920 µin
920 µin
920 µin
920 µin
920 µin
920 µin
920 µin
920 µin
920 µin
Indicator, master
rings, master plugs
TPI = threads per
inch
Length Standards
Up to 22 in
(39 + 16L) µin
Gage blocks, UMM
Angle – Measuring
Equipment
Up to 90°
6.2'
Angle blocks
Surface Finish – Roughness
Average (Ra)
Profilometer
Roughness Specimen
Up to 250 µin
Up to 250 µin
(7.6 + 0.6R) µin
4.0 µin
Roughness patch
profilometer
II. Fastener Industry Specific Gages
Parameter/Equipment
Range
CMC2 (±)
Comments
Major Diameter Gages
Up to 2 in
140 µin
Master gage blocks
Segment Thread Gage
Up to 2 in
220 µin
Master thread plug
Tri-Roll & Adjustable
Thread Gages
Up to 3.375 in
240 µin
Gage blocks
Recess Concentricity
Gages
Up to 1 in
0.0008 in
Master gage pins
& indicator | ||
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1032.01) Revised 12/03/2024 Page 4 of 6
Parameter/Equipment
Range
CMC2 (±)
Comments
Tri-Round Gages
Up to 0.5 in
93 µin
Master gage pins
Fastener Length Gages
Up to 1 in
Up to 6 in
Up to 12 in
290 µin
540 µin
500 µin
Master gage blocks
Internal Thread Gage
Up to 8 in
200 μin
Master rings
“Dimension-All” Fastener
Measuring Gages
Parallelism
Up to 2 in
Up to 2 in
270 µin
97 μin
Master gage blocks &
gage balls
Protrusion Height Gages
Parallelism
Up to 2 in
Up to 2 in
290 µin
97 μin
Master gage blocks &
gage balls
Penetration
Points/Penetration Plugs
Type I, IA, II;
6-lobe, Offset
Cruciform
Hex, Slot, Square
130 μin
32 μin
Measuring microscope
& UMM
UMM
Thread Performance – Test
Plates5
Up to 0.75 in, M1.5 to
M20
250 µin
Hardness tester,
electronic bore gages,
micrometer, plug
gages
III. Mechanical
Parameter/Equipment
Range
CMC2 (±)
Comments
Torque Tools
Up to 600 lbf
1.4 % of rdg
Torque transducer &
staging fixture | to 0.5 in |
| 5 | ASTM E18 | - | See scope document |
| 6 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1032.01) Revised 12/03/2024 Page 6 of 6
Parameter/Equipment
Range
CMC2 (±)
Comments
Force Gages –
Compression & Tension
Up to 600 lbf
0.31 lb
Class F weights
Scales3
Up to 0.25 lb
(> 0.25 to 5) lb
(> 5 to 50) lb
(> 50 to 250) lb
(> 250 to 1000) lb
0.000 23 lb
0.0023 lb
0.0032 lb
0.029 lb
1.2 lb
Class F weights
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches
and R is the numerical value of the resolution of the device in microinches.
5 Uncertainty is a function of the three characteristics of hardness, thickness, and diameter of the hole.
6 Adjustable thread rings are set to applicable specifications using calibrated master set plug gages.
7 This scope meets A2LA’s P112 Flexible Scope Policy.
8 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | to 600 lbf |
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
GREENSLADE & CO., INC.
Fort Worth, TX
for technical competence in the field of
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories . This laboratory also meets R205 – Specific
Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a
defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 20th day of September 2024
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 1032.01
Valid to October 31, 2026 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Capstone CalibrationRichland Hills, TX · ~11 kmA2LAShares 1 accredited test methodASTM E18
- All-Pro LaboratoryArlington, TX · ~22 kmA2LAShares 1 accredited test methodASTM E18
- Trescal, Inc. - Dallas, TXIrving, TX · ~37 kmA2LAShares 1 accredited test methodASTM E18
- CROSS TECHNOLOGIES, INC - OKLAHOMA CITYOklahoma City, OK · ~303 kmA2LAShares 1 accredited test methodASTM E18
- Probata CorporationEdmond, OK · ~323 kmA2LAShares 1 accredited test methodASTM E18
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.