RJL Micro & Analytic
Im Entenfang 11, 76689, Karlsdorf-Neuthard, Germany
Visit website- Accredited standards
- 2
- DAKKS certificates
- 3
- Site in our directory
- 1
What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 2 standard numbers and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.
ISO 16232Road vehicles - Cleanliness of components and systems
VDA 19
ISO 16232 2018-12 Road vehicles - Cleanliness of components and systems VDA 19 Teil 1 2015-03 Inspe ction of Technical Cleanliness - Particulate Contamination of Functionally Relevant Automotive Components 2
ISO 16232; VDA 19 Part 1
Read from the scope as published by DAKKS. Register refreshed 2026-11-20.
Scope as published by DAKKS
6 lines
ISO/IEC 17025
ActiveD-PL-11311-01-00
Accredited scope, certificate D-PL-11311-01-00
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001 | structural components and elements | - |
| 2 | ISO 16232 2018-12 Road vehicles - Cleanliness of components and systems VDA 19 Teil 1 2015-03 Inspe ction of Technical Cleanliness - Particulate Contamination of Functionally Relevant Automotive Components 2 | surfaces and particle membranes; materials, components and products | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveD-PL-11311-01-01
Accredited scope, certificate D-PL-11311-01-01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018 | parts and components | - |
| 2 | ISO 16232; VDA 19 Part 1 | Components and Systems in the Area of Automotive | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveD-PL-11311-01-02
Accredited scope, certificate D-PL-11311-01-02
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018 | - | - |
| 2 | PSEM -AF A-01; MCT -DXR | particles | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Germany
- FADER UmweltanalytikKarlsruhe · ~15 kmDAKKSShares 1 accredited test methodEN ISO 9001
- NEMKOPfinztal · ~16 kmDAKKSShares 1 accredited test methodEN ISO 9001
- Chemisches Labor PiorrNeulußheim · ~17 kmDAKKSShares 1 accredited test methodEN ISO 9001
- LABUS TestlabKarlsruhe · ~17 kmDAKKSShares 1 accredited test methodEN ISO 9001
- PETROLAB GmbH Laboratorium für Mineralöl- und UmweltanalytikSpeyer · ~24 kmDAKKSShares 1 accredited test methodEN ISO 9001
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.