Fred V. Fowler Company LLC DBA Anko Electronics Test & Measurement
1485 Poinsettia Ave., Suite 115, 92081, Vista, CA, United States
Visit website- Scope lines
- 15
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 15 scope lines.
A2LA certificate 3270.01 · 15 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1.1994; ANSI/NCSL Z540.3.2006 | - | to 10 in |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 2 of 14
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
DC Voltage3 – Generate
Up to 329.999 mV
(0.33 to 3.299 999) V
(3.3 to 32.999 99) V
(33 to 329.9999) V
(0.1 to 1) kV
15 μV/V + 1.2 µV
8.9 μV/V + 1.9 µV
10 μV/V + 11 µV
14 μV/V + 0.12 mV
14 μV/V + 1.2 mV
Fluke 5520A
DC Current3 – Generate
Up 329.999 μA
(0.33 to 3.299 99) mA
(3.3 to 32.9999) mA
(33 to 329.999) mA
(0.33 to 1.099 99) A
(1.1 to 2.999 99) A
(3 to 10.999 99) A
(11 to 20.5) A
0.12 mA/A + 16 nA
75 μA/A + 50 nA
77 μA/A + 0.24 µA
80 μA/A + 1.9 µA
0.16 mA/A + 32 µA
0.38 mA/A + 0.20 mA
0.39 mA/A + 0.41 mA
1.3 mA/A + 9.1 mA
Fluke 5520A
DC Power3 – Generate
33 mV to 1020 V:
329.99 mA
2.9999 A
20.5 A
(0.01 to 330) W
330 W to 3 kW
(3 to 20.9) kW
0.14 mW/W + 80 µW
0.39 mW/W + 66 mW
0.85 mW/W + 0.89 W
Fluke 5520A
DC Resistance3 –
Generate
Up to 10.9999 Ω
(11 to 32.9999) Ω
(33 to 109.9999) Ω
(110 to 329.9999) Ω
(0.33 to 1.099 999) kΩ
(1.1 to 3.299 999) kΩ
(3.3 to 10.999 99) kΩ
(11 to 32.9999) kΩ
(33 to 109.9999) kΩ
(110 to 329.9999) kΩ
(0.33 to 1.099 999) MΩ
(1.1 to 3.299 999) MΩ
(3.3 to 10.999 99) MΩ
(11 to 32.9999) MΩ
(33 to 109.9999) MΩ
(110 to 329.9999) MΩ
(330 to 1100) MΩ
31 µΩ/Ω + 0.78 mΩ
22 µΩ/Ω + 1.2 mΩ
22 μΩ/Ω + 1.1 mΩ
22 μΩ/Ω + 1.5 mΩ
22 μΩ/Ω + 1.6 mΩ
23 μΩ/Ω + 14 mΩ
23 μΩ/Ω + 16 mΩ
23 μΩ/Ω + 0.16 Ω
23 μΩ/Ω + 0.16 Ω
26 μΩ/Ω + 1.5 Ω
25 μΩ/Ω + 1.7 Ω
49 μΩ/Ω + 21 Ω
0.10 mΩ/Ω + 39 Ω
0.21 mΩ/Ω + 1.9 kΩ
0.40 mΩ/Ω + 2.3 kΩ
2.3 mΩ/Ω + 76 kΩ
12 mΩ/Ω + 0.38 MΩ
Fluke 5520A | to 1100 MΩ |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 3 of 14
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Capacitance3 – Generate
(0.19 to 0.3999) nF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) µF
(1.1 to 3.299 99) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 1.099 99) mF
(1.1 to 3.299 99) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
(33 to 109.999) mF
0.37 % + 8.0 pF
0.42 % + 7.9 pF
0.40 % + 7.8 pF
0.20 % + 8.3 pF
0.20 % + 77 pF
0.20 % + 83 pF
0.21 % + 0.21 nF
0.23 % + 0.63 nF
0.21 % + 2.3 nF
0.33 % + 0.90 nF
0.33 % + 22 nF
0.41 % + 45 nF
0.37 % + 0.23 µF
0.32 % + 1.3 µF
0.35 % + 2.5 µF
0.36 % + 7.6 µF
0.59 % + 22 µF
0.85 % + 77 µF
Fluke 5520A
Electrical Simulation of
Thermocouples3 –
Generate & Measure
Type E
Type J
Type K
Type N
Type R
Type S
(-250 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to 760) °C
(760 to 1200) °C
(-200 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-270 to 410) °C
(410 to 1300) °C
(-50 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1768) °C
(-50 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1768) °C
0.12 °C
0.13 °C
0.12 °C
0.20 °C
0.12 °C
0.15 °C
0.12 °C
0.16 °C
0.19 °C
0.12 °C
0.17 °C
0.15 °C
0.14 °C
0.17 °C
0.18 °C
0.14 °C
0.18 °C
0.20 °C
0.17 °C
Fluke 5520A,
Keysight 3458A (Opt.
002), with Omega
TRCIII-A ice point | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 4 of 14
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
Thermocouples3 –
Generate (cont)
Type T
(-270 to 400) °C
0.12 °C
Fluke 5520A,
Keysight 3458A (Opt.
002), with Omega
TRCIII-A ice point
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage3 – Generate
(1 to 33) mV
(33 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
(0.045 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
(0.045 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(0.045 to 1) kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(0.045 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
0.062 % + 4.9 µV
0.013 % + 4.9 µV
0.016 % + 4.9 µV
0.11 % + 3.8 µV
0.39 % + 25 µV
0.94 % + 57 µV
0.023 % + 6.6 µV
0.011 % + 6.7 µV
0.012 % + 7.8 µV
0.034 % + 13 µV
0.088 % + 51 µV
0.22 % + 0.13 mV
0.024 % + 38 µV
0.012 % + 46 µV
0.015 % + 46 µV
0.026 % + 48 µV
0.072 % + 0.43 mV
0.28 % + 2.1 mV
0.023 % + 0.51 mV
0.012 % + 0.46 mV
0.021 % + 0.20 mV
0.031 % + 0.58 mV
0.094 % + 6.0 mV
0.015 % + 1.5 mV
0.016 % + 4.6 mV
0.020 % + 3.4 mV
0.026 % + 2.5 mV
0.024 % + 6.9 mV
0.018 % + 23 mV
0.024 % + 8.3 mV
Fluke 5520A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 5 of 14
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Current3 – Generate
(29 to 330) μA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 1.099 99) A
(1.1 to 2.999 99) A
(3 to 10.999 99) A
(11 to 20.5) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
(0.1 to 1) kHz
(1 to 5) kHz
(45 to 100) Hz
(0.1 to 1) kHz
(1 to 5) kHz
0.15 % + 95 nA
0.12 % + 72 nA
0.098 % + 78 nA
0.23 % + 0.13 µA
0.62 % + 0.16 µA
3.9 % + 0.60 µA
0.14 % + 0.56 µA
0.090 % + 0.39 µA
0.078 % + 0.12 µA
0.16 % + 0.16 µA
0.41 % + 0.20 µA
0.78 % + 0.46 µA
0.14 % + 3.2 µA
0.065 % + 3.6 µA
0.034 % + 1.5 µA
0.064 % + 1.5 µA
0.16 % + 3.0 µA
0.32 % + 3.0 µA
0.14 % + 31 µA
0.065 % + 36 µA
0.033 % + 16 µA
0.079 % + 39 µA
0.16 % + 76 µA
0.32 % + 0.15 mA
0.13 % + 0.19 mA
0.040 % + 81 µA
0.46 % + 0.79 mA
1.9 % + 3.9 mA
0.14 % + 32 µA
0.058 % + 34 µA
0.47 % + 0.76 mA
1.9 % + 3.9 mA
0.040 % + 2.7 mA
0.081 % + 1.6 mA
2.3 % + 1.6 mA
0.096 % + 3.8 mA
0.12 % + 3.8 mA
2.3 % + 3.9 mA
Fluke 5520A | ||
| 6 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 6 of 14
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
AC Power3 – Generate
(45 to 65) Hz
PF = 1
330 mV, 20.5 A
1020 V, 20.5 A
0.01 W to 6.5 kW
0.01 W to 20.9 kW
0.53 mW/W + 0.45 W
0.71 mW/W + 97 mW
Fluke 5520A
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
Phase3 – Generate
(+/-)179.99 (ΔΦ°)
V vs. V
V vs. I
(10 to 65) Hz
(65 to 500) Hz
500 Hz to 1 kHz
(1 to 5) kHz
(1 to 65) Hz
(65 to 500) Hz
500 Hz to 1 kHz
(1 to 5) kHz
0.22°
0.28°
0.43°
2.0°
0.22°
0.28°
0.43°
2.0°
Fluke 5520A | 45 to 65 Hz |
| 7 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 7 of 14
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
Oscilloscopes3 –
Level Sine Amplitude:
50 kHz Reference
Level Sine Amplitude:
5 mV to 5.5 V
(Relative to 50 kHz
Reference)
Square Wave
Amplitude:
Into 1 MΩ Load
Into 50 Ω Load
DC Level
Time Marker
Output Into 50 Ω
Edge Transition
Time
5 mV to 5.5 V
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
1 mV to 130 V
1 mV to 6.6 V
Up to 130 V into 1 MΩ
Up to 6.6 V into 50 Ω
1 ns to 20 ms
50 ms to 5 s
1 kHz to 10 MHz
1.6 % + 0.23 mV
1.4 % + 77 µV
1.8 % + 79 µV
3.2 % + 79 µV
4.0 % + 80 µV
0.078 % + 32 µV
0.20 % + 32 µV
0.054 % + 32 µV
0.24 % + 30 µV
0.12 % + 2.5 ps
0.39 % + 0.18 ms
82 ps
Fluke 5520A/
SC1100
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
DC Voltage3 – Measure
Up to 100 mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(0.1 to 1) kV
5.9 μV/V + 0.30 µV
4.6 μV/V + 0.30 µV
4.6 μV/V + 0.50 µV
7.0 μV/V + 30 µV
44 μV/V + 0.10 mV
Keysight 3458A/002
DC Resistance3 –
Measure
(0 to 10) Ω
(10 to 100) Ω
(100 to 1000) Ω
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(100 to 1) GΩ
18 µΩ/Ω + 50 µΩ
15 µΩ/Ω + 0.5 mΩ
12 µΩ/Ω + 0.5 mΩ
12 µΩ/Ω + 5 mΩ
12 µΩ/Ω + 50 mΩ
18 µΩ/Ω + 2 Ω
59 µΩ/Ω + 0.1 kΩ
0.58 mΩ/Ω + 1 kΩ
5.8 mΩ/Ω + 10 kΩ
Keysight 3458A/002 | to 1100 MHz |
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 8 of 14
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
DC Current3 – Measure
(0 to 100) nA
(0.1 to 1) μA
(1 to 10) μA
(10 to 100) μA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
0.19 mA/A + 0.04 nA
36 µA/A + 0.04 nA
24 µA/A + 0.1 nA
23 µA/A + 0.8 nA
23 µA/A + 5 nA
23 µA/A + 50 nA
41 µA/A + 0.5 µA
0.13 mA/A + 10 µA
Keysight 3458A/002
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage3 – Measure
(1 to 10) mV
(10 to 100) mV
(0.1 to 1) V
(1 to 10) V
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(2 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
0.24 mV/V + 1.1 µV
0.36 mV/V + 1.1 µV
1.2 mV/V + 1.1 µV
5.8 mV/V + 1.1 µV
46 mV/V + 2 µV
87 µV/V + 2 µV
0.17 mV/V + 2.0 µV
0.36 mV/V + 2.0 µV
0.93 mV/V + 2.0 µV
3.5 mV/V + 10 µV
12 mV/V + 10 µV
17 mV/V + 10 µV
85 µV/V + 20 µV
0.16 mV/V + 20 µV
0.35 mV/V + 20 µV
0.93 mV/V + 20 µV
3.5 mV/V + 0.10 mV
12 mV/V + 0.10 mV
17 mV/V + 0.10 mV
46 mV/V + 0.70 mV
46 mV/V + 0.80 mV
0.17 V/V + 1.0 mV
89 µV/V + 0.40 mV
85 µV/V + 0.20 mV
0.16 mV/V + 0.20 mV
0.35 mV/V + 0.20 mV
0.93 mV/V + 0.20 mV
Keysight 3458A/002 | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 9 of 14
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage3 – Measure (cont.)
(1 to 10) V
(10 to 100) V
(100 to 700) V
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(2 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
40 Hz to 1 kHz
(1 to 20) kHz
3.5 mV/V + 1.0 mV
12 mV/V + 1.0 mV
17 mV/V + 1 mV
46 mV/V + 7 mV
46 mV/V + 8 mV
0.17 V/V + 10 mV
0.23 mV/V + 2.0 mV
0.23 mV/V + 2.0 mV
0.41 mV/V + 2.0 mV
1.4 mV/V + 2.0 mV
0.33 mV/V + 20 mV
0.49 mV/V + 20 mV
Keysight 3458A/002
AC High Voltage3 – Measure
(1 to 4) kV
(4 to 30) kV
60 Hz
60 Hz
6.0 V/kV
5.6 V/kV + 3.4 V
Ross Engineering
VD30-8.3-
A-K-AAA & Fluke
87 III
AC Current3 – Measure
(10 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 1 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
4.6 mA/A + 30 nA
1.7 mA/A + 30 nA
0.7 mA/A + 30 nA
0.7 m A/A + 30 nA
4.6 mA/A + 0.2 µA
1.7 mA/A + 0.2 µA
0.7 mA/A + 0.2 µA
0.35 mA/A + 0.2 µA
0.7 mA/A + 0.2 µA
4.6 mA/A + 0.4 µA
6.4 mA/A + 1.5 µA
4.6 mA/A + 2 µA
1.7 mA/A + 2 µA
0.7 mA/A + 2 µA
0.35 mA/A + 2 µA
0.7 mA/A + 2 µA
4.6 mA/A + 4 µA
6.4 mA/A + 15 µA
Keysight 3458A/002 | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 10 of 14
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
AC Current3 – Measure
(cont.)
(10 to 100) mA
(0.1 to 1) A
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
4.6 mA/A + 20 µA
1.7 mA/A + 20 µA
0.7 mA/A + 20 µA
0.35 mA/A + 20 µA
0.7 mA/A + 20 µA
4.6 mA/A + 40 µA
6.4 mA/A + 0.15 mA
4.6 mA/A + 0.2 mA
1.9 mA/A + 0.2 mA
0.93 mA/A + 0.2 mA
1.2 mA/A + 0.2 mA
3.5 mA/A + 0.2 mA
12 mA/A + 0.4 mA
Keysight 3458A/002
DC High Current3 –
Measure
(1 to 15) A
(15 to 100) A
1.3 mA/A – 0.50 mA
1.7 mA/A + 0.96 mA
Agilent 3458A/002
w/ L&N 15A shunt
w/ Weston 100A
shunt
DC High Voltage3 –
Measure
(1 to 4) kV
(4 to 30) kV
1.0 V/kV + 0.60 V
0.98 V/kV + 8.0 V
Ross Engineering
VD30-8.3-
A-K-AAA
& Fluke 87 III
III. Electrical – RF/Microwave
Parameter/Range
Frequency
CMC2, 4, 7 (±)
Comments
Power Sensor
Calibration Factor3 –
Measure
10 µW to 10 mW
100 kHz
300 kHz
500 kHz
1 MHz
(3 to 5) MHz
(10 to 50) MHz
2.4 % CF
0.71 % CF
0.66 % CF
0.66 % CF
0.65 % CF
0.47 % CF
Direct comparison
transfer method
Keysight 8482A/H84
11667A power splitter | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 11 of 14
Parameter/Range
Frequency
CMC2, 4, 7 (±)
Comments
Power Sensor
Calibration Factor3 –
Measure (cont.)
10 µW to 10 mW
100 MHz
300 MHz to 1 GHz
1.5 GHz
2 GHz
2.5 GHz
3 GHz
3.5 GHz
(3.7 to 4.2) GHz
10 MHz
(30 to 50) MHz
(100 to 800) MHz
800 MHz to 2 GHz
3 GHz
4 GHz
5 GHz
6 GHz
7 GHz
8 GHz
9 GHz
10 GHz
11 GHz
12 GHz
(12.4 to 13) GHz
14 GHz
15 GHz
16 GHz
17 GHz
18 GHz
0.43 % CF
0.53 % CF
0.54 % CF
0.55 % CF
0.59 % CF
0.63 % CF
0.72 % CF
0.73 % CF
0.77 % CF
0.48 % CF
0.41 % CF
0.48 % CF
0.47 % CF
0.54 % CF
0.51 % CF
0.58 % CF
0.60 % CF
0.79 % CF
0.81 % CF
0.70 % CF
0.74 % CF
0.92 % CF
0.99 % CF
0.90 % CF
0.77 % CF
0.92 % CF
1.3 % CF
2.3 % CF
Keysight 8481A/H84
11667A power splitter
IV. Mechanical
Parameter/Equipment
Range
CMC2, 4, 7 (±)
Comments
Pressure3 –
Measure & Measuring
Equipment
(-12 to 0) psi
(0 to 10) in. H2O
(0 to 1) psi
(1 to 5) psi
(5 to 12) psi
(12 to 30) psi
0.025 psi
0.0031 in. H2O
0.000 62 psi
0.0014 psi
0.0040 psi
0.0086 psi
Fluke 718 100G
Fluke 700P01
Fluke 700P02
Fluke 700P03
Fluke 700P05 | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 12 of 14
Parameter/Equipment
Range
CMC2, 4, 7 (±)
Comments
Pressure3 –
Measure & Measuring
Equipment (cont.)
(30 to 100) psi
(100 to 300) psi
(300 to 750) psi
(750 to 3000) psi
(3000 to 5000) psi
(5000 to 10 000) psi
0.027 psi
0.0039 % + 0.074 psi
0.036 %
0.025 % + 0.086 psi
0.0072 % + 1.4 psi
0.076 % + 2.1 psi
Fluke 718 100G
Fluke 718 300G
Crystal 3KPSIXP2I
w/ Omega HPP-10K
Crystal 10KPSIXP2I
w/ Omega HPP-10K
Absolute Pressure3 –
Measure
(0 to 15) psia
0.0038 psia
Fluke 700PA4
Absolute Pressure3 –
Measuring Equipment
(15 to 30) psia
(30 to 100) psia
(100 to 300) psia
(300 to 750) psia
(750 to 3000) psia
(3000 to 5000) psia
(5000 to 10 000) psia
0.020 % + 0.0042 psia
0.027 psia
0.0039 % + 0.074 psia
0.036 %
0.025 % + 0.086 psia
0.0072 % + 1.4 psia
0.076 % + 2.1 psia
Fluke 700P05 &
700PA4
Fluke 718 100G &
700PA4
Fluke 718 300G &
700PA4
Crystal 3KPSIXP2I
w/Omega HPP-10K &
Fluke 700PA4
Crystal 10KPSIXP2I
w/Omega HPP-10K &
Fluke 700PA4
V. Thermodynamics
Parameter/Equipment
Range
CMC2, 7, 9 (±)
Comments
Temperature3 – Measure
(-196 to 0) °C
(0 to 420) °C
(0.023 + 0.0001T) °C
(0.026 + 0.0001T) °C
Burns 12005 SPRT w/
Keysight 3458A
Temperature3 –
Measuring Equipment
(-15 to 25) °C
(25 to 420) °C
(0.06 + 0.0002T) °C
(0.03 + 0.0002T) °C
Burns 12005 SPRT w/
Keysight 3458A &
temperature bath
Burns 12005 SPRT w/
Keysight 3458A &
Ametek dry well | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 13 of 14
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Relative Humidity3
Measure
(0 to 90) % RH
(90 to 100) % RH
1.3 % RH
2.0 % RH
Vaisala
MI70/HMP77B
Relative Humidity3 –
Measuring Equipment
11 % RH
75 % RH
97 % RH
1.6 % RH
2.0 % RH
2.6 % RH
Humidity calibrator
w/reference salt
solutions
VI. Time & Frequency
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Frequency3 – Measure
(1 to 10) Hz
10 Hz to 3 GHz
(3 to 26.5) GHz
0.16 mHz/Hz + 1.7 mHz
11 pHzHz/Hz + 2.9 mHz
0.27 pHz/Hz + 1.2 Hz
Datum 9390 GPS w/
HP 53132A Opt. 030
Datum 9390 GPS w/
HP 5350B
Frequency3 – Measuring
Equipment
DC to 10 Hz
10 Hz to 80 MHz
80 MHz to 3 GHz
(3 to 50) GHz
0.16 mHz/Hz + 1.7 mHz
67 pHz/Hz + 1.8 mHz
8.8 pHz/Hz + 9.0 mHz
0.27 pHz/Hz + 1.2 Hz
Datum 9390 GPS
w/Keysight 33250A
Datum 9390 GPS
w/Keysight 83650B
Stopwatches/Timers
Up to 24 hours
39 ms/d
Totalize method using
generator and counter
______________________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavio r of the customer’s device and to influences from the
circumstances of the specific calibration. | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 14 of 14
3 Field calibration service is available for this calibration and this laboratory meets A2LA R104 – General
Requirements: Accreditation of Field Testing and Field Calibration Laboratories for these calibrations.
Please note the actual measurement uncertainties achievable on a customer's site can normally be
expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such
as the environment at the place of calibration and for other possible adverse effects such as those caused
by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced
by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result
in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC.
4 In the statement of CMC, percentages are to be read as percent of reading unless otherwise noted.
5 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
6 This scope meets A2LA’s P112 Flexible Scope Policy.
7 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
8 In the statement of CMC, L is the numerical value of the nominal length of the device measured in
inches.
9 In the statement of CMC, T is the absolute, numerical value of the nominal temperature of the device
measured in degrees Celsius. | ||
| 15 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Molecular BioProducts d.b.a. Unity Lab ServicesCarlsbad, CA · ~8 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Spektra Labs by APS DynamicsSan Juan Capistrano, CA · ~51 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Flagship Lab ServicesSan Diego, CA · ~54 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- GL TechnologiesSan Diego, CA · ~54 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- MATPHIL TECHNOLOGIES, INC. DBA ACCUTEKSan Diego, CA · ~54 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.