Registers refreshed 2026-11-20.See refresh dates
United States

Fred V. Fowler Company LLC DBA Anko Electronics Test & Measurement

1485 Poinsettia Ave., Suite 115, 92081, Vista, CA, United States

Visit website
A2LA 3270.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
15
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 15 scope lines.

A2LA certificate 3270.01 · 15 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1.1994; ANSI/NCSL Z540.3.2006-to 10 in
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 2 of 14 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 5 (±) Comments DC Voltage3 – Generate Up to 329.999 mV (0.33 to 3.299 999) V (3.3 to 32.999 99) V (33 to 329.9999) V (0.1 to 1) kV 15 μV/V + 1.2 µV 8.9 μV/V + 1.9 µV 10 μV/V + 11 µV 14 μV/V + 0.12 mV 14 μV/V + 1.2 mV Fluke 5520A DC Current3 – Generate Up 329.999 μA (0.33 to 3.299 99) mA (3.3 to 32.9999) mA (33 to 329.999) mA (0.33 to 1.099 99) A (1.1 to 2.999 99) A (3 to 10.999 99) A (11 to 20.5) A 0.12 mA/A + 16 nA 75 μA/A + 50 nA 77 μA/A + 0.24 µA 80 μA/A + 1.9 µA 0.16 mA/A + 32 µA 0.38 mA/A + 0.20 mA 0.39 mA/A + 0.41 mA 1.3 mA/A + 9.1 mA Fluke 5520A DC Power3 – Generate 33 mV to 1020 V: 329.99 mA 2.9999 A 20.5 A (0.01 to 330) W 330 W to 3 kW (3 to 20.9) kW 0.14 mW/W + 80 µW 0.39 mW/W + 66 mW 0.85 mW/W + 0.89 W Fluke 5520A DC Resistance3 – Generate Up to 10.9999 Ω (11 to 32.9999) Ω (33 to 109.9999) Ω (110 to 329.9999) Ω (0.33 to 1.099 999) kΩ (1.1 to 3.299 999) kΩ (3.3 to 10.999 99) kΩ (11 to 32.9999) kΩ (33 to 109.9999) kΩ (110 to 329.9999) kΩ (0.33 to 1.099 999) MΩ (1.1 to 3.299 999) MΩ (3.3 to 10.999 99) MΩ (11 to 32.9999) MΩ (33 to 109.9999) MΩ (110 to 329.9999) MΩ (330 to 1100) MΩ 31 µΩ/Ω + 0.78 mΩ 22 µΩ/Ω + 1.2 mΩ 22 μΩ/Ω + 1.1 mΩ 22 μΩ/Ω + 1.5 mΩ 22 μΩ/Ω + 1.6 mΩ 23 μΩ/Ω + 14 mΩ 23 μΩ/Ω + 16 mΩ 23 μΩ/Ω + 0.16 Ω 23 μΩ/Ω + 0.16 Ω 26 μΩ/Ω + 1.5 Ω 25 μΩ/Ω + 1.7 Ω 49 μΩ/Ω + 21 Ω 0.10 mΩ/Ω + 39 Ω 0.21 mΩ/Ω + 1.9 kΩ 0.40 mΩ/Ω + 2.3 kΩ 2.3 mΩ/Ω + 76 kΩ 12 mΩ/Ω + 0.38 MΩ Fluke 5520A
to 1100 MΩ
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 3 of 14 Parameter/Equipment Range CMC2, 5 (±) Comments Capacitance3 – Generate (0.19 to 0.3999) nF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099 99) µF (1.1 to 3.299 99) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.099 99) mF (1.1 to 3.299 99) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 109.999) mF 0.37 % + 8.0 pF 0.42 % + 7.9 pF 0.40 % + 7.8 pF 0.20 % + 8.3 pF 0.20 % + 77 pF 0.20 % + 83 pF 0.21 % + 0.21 nF 0.23 % + 0.63 nF 0.21 % + 2.3 nF 0.33 % + 0.90 nF 0.33 % + 22 nF 0.41 % + 45 nF 0.37 % + 0.23 µF 0.32 % + 1.3 µF 0.35 % + 2.5 µF 0.36 % + 7.6 µF 0.59 % + 22 µF 0.85 % + 77 µF Fluke 5520A Electrical Simulation of Thermocouples3 – Generate & Measure Type E Type J Type K Type N Type R Type S (-250 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to 760) °C (760 to 1200) °C (-200 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-270 to 410) °C (410 to 1300) °C (-50 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1768) °C (-50 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1768) °C 0.12 °C 0.13 °C 0.12 °C 0.20 °C 0.12 °C 0.15 °C 0.12 °C 0.16 °C 0.19 °C 0.12 °C 0.17 °C 0.15 °C 0.14 °C 0.17 °C 0.18 °C 0.14 °C 0.18 °C 0.20 °C 0.17 °C Fluke 5520A, Keysight 3458A (Opt. 002), with Omega TRCIII-A ice point
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 4 of 14 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouples3 – Generate (cont) Type T (-270 to 400) °C 0.12 °C Fluke 5520A, Keysight 3458A (Opt. 002), with Omega TRCIII-A ice point Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage3 – Generate (1 to 33) mV (33 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (0.045 to 1) kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz 0.062 % + 4.9 µV 0.013 % + 4.9 µV 0.016 % + 4.9 µV 0.11 % + 3.8 µV 0.39 % + 25 µV 0.94 % + 57 µV 0.023 % + 6.6 µV 0.011 % + 6.7 µV 0.012 % + 7.8 µV 0.034 % + 13 µV 0.088 % + 51 µV 0.22 % + 0.13 mV 0.024 % + 38 µV 0.012 % + 46 µV 0.015 % + 46 µV 0.026 % + 48 µV 0.072 % + 0.43 mV 0.28 % + 2.1 mV 0.023 % + 0.51 mV 0.012 % + 0.46 mV 0.021 % + 0.20 mV 0.031 % + 0.58 mV 0.094 % + 6.0 mV 0.015 % + 1.5 mV 0.016 % + 4.6 mV 0.020 % + 3.4 mV 0.026 % + 2.5 mV 0.024 % + 6.9 mV 0.018 % + 23 mV 0.024 % + 8.3 mV Fluke 5520A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 5 of 14 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current3 – Generate (29 to 330) μA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.099 99) A (1.1 to 2.999 99) A (3 to 10.999 99) A (11 to 20.5) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz (0.1 to 1) kHz (1 to 5) kHz (45 to 100) Hz (0.1 to 1) kHz (1 to 5) kHz 0.15 % + 95 nA 0.12 % + 72 nA 0.098 % + 78 nA 0.23 % + 0.13 µA 0.62 % + 0.16 µA 3.9 % + 0.60 µA 0.14 % + 0.56 µA 0.090 % + 0.39 µA 0.078 % + 0.12 µA 0.16 % + 0.16 µA 0.41 % + 0.20 µA 0.78 % + 0.46 µA 0.14 % + 3.2 µA 0.065 % + 3.6 µA 0.034 % + 1.5 µA 0.064 % + 1.5 µA 0.16 % + 3.0 µA 0.32 % + 3.0 µA 0.14 % + 31 µA 0.065 % + 36 µA 0.033 % + 16 µA 0.079 % + 39 µA 0.16 % + 76 µA 0.32 % + 0.15 mA 0.13 % + 0.19 mA 0.040 % + 81 µA 0.46 % + 0.79 mA 1.9 % + 3.9 mA 0.14 % + 32 µA 0.058 % + 34 µA 0.47 % + 0.76 mA 1.9 % + 3.9 mA 0.040 % + 2.7 mA 0.081 % + 1.6 mA 2.3 % + 1.6 mA 0.096 % + 3.8 mA 0.12 % + 3.8 mA 2.3 % + 3.9 mA Fluke 5520A
6--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 6 of 14 Parameter/Equipment Range CMC2, 5 (±) Comments AC Power3 – Generate (45 to 65) Hz PF = 1 330 mV, 20.5 A 1020 V, 20.5 A 0.01 W to 6.5 kW 0.01 W to 20.9 kW 0.53 mW/W + 0.45 W 0.71 mW/W + 97 mW Fluke 5520A Parameter/Range Frequency CMC2, 5 (±) Comments Phase3 – Generate (+/-)179.99 (ΔΦ°) V vs. V V vs. I (10 to 65) Hz (65 to 500) Hz 500 Hz to 1 kHz (1 to 5) kHz (1 to 65) Hz (65 to 500) Hz 500 Hz to 1 kHz (1 to 5) kHz 0.22° 0.28° 0.43° 2.0° 0.22° 0.28° 0.43° 2.0° Fluke 5520A
45 to 65 Hz
7--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 7 of 14 Parameter/Range Frequency CMC2, 5 (±) Comments Oscilloscopes3 – Level Sine Amplitude: 50 kHz Reference Level Sine Amplitude: 5 mV to 5.5 V (Relative to 50 kHz Reference) Square Wave Amplitude: Into 1 MΩ Load Into 50 Ω Load DC Level Time Marker Output Into 50 Ω Edge Transition Time 5 mV to 5.5 V 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz 1 mV to 130 V 1 mV to 6.6 V Up to 130 V into 1 MΩ Up to 6.6 V into 50 Ω 1 ns to 20 ms 50 ms to 5 s 1 kHz to 10 MHz 1.6 % + 0.23 mV 1.4 % + 77 µV 1.8 % + 79 µV 3.2 % + 79 µV 4.0 % + 80 µV 0.078 % + 32 µV 0.20 % + 32 µV 0.054 % + 32 µV 0.24 % + 30 µV 0.12 % + 2.5 ps 0.39 % + 0.18 ms 82 ps Fluke 5520A/ SC1100 Parameter/Equipment Range CMC2, 5 (±) Comments DC Voltage3 – Measure Up to 100 mV (0.1 to 1) V (1 to 10) V (10 to 100) V (0.1 to 1) kV 5.9 μV/V + 0.30 µV 4.6 μV/V + 0.30 µV 4.6 μV/V + 0.50 µV 7.0 μV/V + 30 µV 44 μV/V + 0.10 mV Keysight 3458A/002 DC Resistance3 – Measure (0 to 10) Ω (10 to 100) Ω (100 to 1000) Ω (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ (100 to 1) GΩ 18 µΩ/Ω + 50 µΩ 15 µΩ/Ω + 0.5 mΩ 12 µΩ/Ω + 0.5 mΩ 12 µΩ/Ω + 5 mΩ 12 µΩ/Ω + 50 mΩ 18 µΩ/Ω + 2 Ω 59 µΩ/Ω + 0.1 kΩ 0.58 mΩ/Ω + 1 kΩ 5.8 mΩ/Ω + 10 kΩ Keysight 3458A/002
to 1100 MHz
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 8 of 14 Parameter/Equipment Range CMC2, 5 (±) Comments DC Current3 – Measure (0 to 100) nA (0.1 to 1) μA (1 to 10) μA (10 to 100) μA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A 0.19 mA/A + 0.04 nA 36 µA/A + 0.04 nA 24 µA/A + 0.1 nA 23 µA/A + 0.8 nA 23 µA/A + 5 nA 23 µA/A + 50 nA 41 µA/A + 0.5 µA 0.13 mA/A + 10 µA Keysight 3458A/002 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage3 – Measure (1 to 10) mV (10 to 100) mV (0.1 to 1) V (1 to 10) V 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 2) MHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 2) MHz (2 to 4) MHz (4 to 8) MHz (8 to 10) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.24 mV/V + 1.1 µV 0.36 mV/V + 1.1 µV 1.2 mV/V + 1.1 µV 5.8 mV/V + 1.1 µV 46 mV/V + 2 µV 87 µV/V + 2 µV 0.17 mV/V + 2.0 µV 0.36 mV/V + 2.0 µV 0.93 mV/V + 2.0 µV 3.5 mV/V + 10 µV 12 mV/V + 10 µV 17 mV/V + 10 µV 85 µV/V + 20 µV 0.16 mV/V + 20 µV 0.35 mV/V + 20 µV 0.93 mV/V + 20 µV 3.5 mV/V + 0.10 mV 12 mV/V + 0.10 mV 17 mV/V + 0.10 mV 46 mV/V + 0.70 mV 46 mV/V + 0.80 mV 0.17 V/V + 1.0 mV 89 µV/V + 0.40 mV 85 µV/V + 0.20 mV 0.16 mV/V + 0.20 mV 0.35 mV/V + 0.20 mV 0.93 mV/V + 0.20 mV Keysight 3458A/002
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 9 of 14 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage3 – Measure (cont.) (1 to 10) V (10 to 100) V (100 to 700) V (100 to 300) kHz (0.3 to 1) MHz (1 to 2) MHz (2 to 4) MHz (4 to 8) MHz (8 to 10) MHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 40 Hz to 1 kHz (1 to 20) kHz 3.5 mV/V + 1.0 mV 12 mV/V + 1.0 mV 17 mV/V + 1 mV 46 mV/V + 7 mV 46 mV/V + 8 mV 0.17 V/V + 10 mV 0.23 mV/V + 2.0 mV 0.23 mV/V + 2.0 mV 0.41 mV/V + 2.0 mV 1.4 mV/V + 2.0 mV 0.33 mV/V + 20 mV 0.49 mV/V + 20 mV Keysight 3458A/002 AC High Voltage3 – Measure (1 to 4) kV (4 to 30) kV 60 Hz 60 Hz 6.0 V/kV 5.6 V/kV + 3.4 V Ross Engineering VD30-8.3- A-K-AAA & Fluke 87 III AC Current3 – Measure (10 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 1 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz 4.6 mA/A + 30 nA 1.7 mA/A + 30 nA 0.7 mA/A + 30 nA 0.7 m A/A + 30 nA 4.6 mA/A + 0.2 µA 1.7 mA/A + 0.2 µA 0.7 mA/A + 0.2 µA 0.35 mA/A + 0.2 µA 0.7 mA/A + 0.2 µA 4.6 mA/A + 0.4 µA 6.4 mA/A + 1.5 µA 4.6 mA/A + 2 µA 1.7 mA/A + 2 µA 0.7 mA/A + 2 µA 0.35 mA/A + 2 µA 0.7 mA/A + 2 µA 4.6 mA/A + 4 µA 6.4 mA/A + 15 µA Keysight 3458A/002
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 10 of 14 Parameter/Equipment Range CMC2, 5 (±) Comments AC Current3 – Measure (cont.) (10 to 100) mA (0.1 to 1) A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz 4.6 mA/A + 20 µA 1.7 mA/A + 20 µA 0.7 mA/A + 20 µA 0.35 mA/A + 20 µA 0.7 mA/A + 20 µA 4.6 mA/A + 40 µA 6.4 mA/A + 0.15 mA 4.6 mA/A + 0.2 mA 1.9 mA/A + 0.2 mA 0.93 mA/A + 0.2 mA 1.2 mA/A + 0.2 mA 3.5 mA/A + 0.2 mA 12 mA/A + 0.4 mA Keysight 3458A/002 DC High Current3 – Measure (1 to 15) A (15 to 100) A 1.3 mA/A – 0.50 mA 1.7 mA/A + 0.96 mA Agilent 3458A/002 w/ L&N 15A shunt w/ Weston 100A shunt DC High Voltage3 – Measure (1 to 4) kV (4 to 30) kV 1.0 V/kV + 0.60 V 0.98 V/kV + 8.0 V Ross Engineering VD30-8.3- A-K-AAA & Fluke 87 III III. Electrical – RF/Microwave Parameter/Range Frequency CMC2, 4, 7 (±) Comments Power Sensor Calibration Factor3 – Measure 10 µW to 10 mW 100 kHz 300 kHz 500 kHz 1 MHz (3 to 5) MHz (10 to 50) MHz 2.4 % CF 0.71 % CF 0.66 % CF 0.66 % CF 0.65 % CF 0.47 % CF Direct comparison transfer method Keysight 8482A/H84 11667A power splitter
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 11 of 14 Parameter/Range Frequency CMC2, 4, 7 (±) Comments Power Sensor Calibration Factor3 – Measure (cont.) 10 µW to 10 mW 100 MHz 300 MHz to 1 GHz 1.5 GHz 2 GHz 2.5 GHz 3 GHz 3.5 GHz (3.7 to 4.2) GHz 10 MHz (30 to 50) MHz (100 to 800) MHz 800 MHz to 2 GHz 3 GHz 4 GHz 5 GHz 6 GHz 7 GHz 8 GHz 9 GHz 10 GHz 11 GHz 12 GHz (12.4 to 13) GHz 14 GHz 15 GHz 16 GHz 17 GHz 18 GHz 0.43 % CF 0.53 % CF 0.54 % CF 0.55 % CF 0.59 % CF 0.63 % CF 0.72 % CF 0.73 % CF 0.77 % CF 0.48 % CF 0.41 % CF 0.48 % CF 0.47 % CF 0.54 % CF 0.51 % CF 0.58 % CF 0.60 % CF 0.79 % CF 0.81 % CF 0.70 % CF 0.74 % CF 0.92 % CF 0.99 % CF 0.90 % CF 0.77 % CF 0.92 % CF 1.3 % CF 2.3 % CF Keysight 8481A/H84 11667A power splitter IV. Mechanical Parameter/Equipment Range CMC2, 4, 7 (±) Comments Pressure3 – Measure & Measuring Equipment (-12 to 0) psi (0 to 10) in. H2O (0 to 1) psi (1 to 5) psi (5 to 12) psi (12 to 30) psi 0.025 psi 0.0031 in. H2O 0.000 62 psi 0.0014 psi 0.0040 psi 0.0086 psi Fluke 718 100G Fluke 700P01 Fluke 700P02 Fluke 700P03 Fluke 700P05
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 12 of 14 Parameter/Equipment Range CMC2, 4, 7 (±) Comments Pressure3 – Measure & Measuring Equipment (cont.) (30 to 100) psi (100 to 300) psi (300 to 750) psi (750 to 3000) psi (3000 to 5000) psi (5000 to 10 000) psi 0.027 psi 0.0039 % + 0.074 psi 0.036 % 0.025 % + 0.086 psi 0.0072 % + 1.4 psi 0.076 % + 2.1 psi Fluke 718 100G Fluke 718 300G Crystal 3KPSIXP2I w/ Omega HPP-10K Crystal 10KPSIXP2I w/ Omega HPP-10K Absolute Pressure3 – Measure (0 to 15) psia 0.0038 psia Fluke 700PA4 Absolute Pressure3 – Measuring Equipment (15 to 30) psia (30 to 100) psia (100 to 300) psia (300 to 750) psia (750 to 3000) psia (3000 to 5000) psia (5000 to 10 000) psia 0.020 % + 0.0042 psia 0.027 psia 0.0039 % + 0.074 psia 0.036 % 0.025 % + 0.086 psia 0.0072 % + 1.4 psia 0.076 % + 2.1 psia Fluke 700P05 & 700PA4 Fluke 718 100G & 700PA4 Fluke 718 300G & 700PA4 Crystal 3KPSIXP2I w/Omega HPP-10K & Fluke 700PA4 Crystal 10KPSIXP2I w/Omega HPP-10K & Fluke 700PA4 V. Thermodynamics Parameter/Equipment Range CMC2, 7, 9 (±) Comments Temperature3 – Measure (-196 to 0) °C (0 to 420) °C (0.023 + 0.0001T) °C (0.026 + 0.0001T) °C Burns 12005 SPRT w/ Keysight 3458A Temperature3 – Measuring Equipment (-15 to 25) °C (25 to 420) °C (0.06 + 0.0002T) °C (0.03 + 0.0002T) °C Burns 12005 SPRT w/ Keysight 3458A & temperature bath Burns 12005 SPRT w/ Keysight 3458A & Ametek dry well
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 13 of 14 Parameter/Equipment Range CMC2, 7 (±) Comments Relative Humidity3 Measure (0 to 90) % RH (90 to 100) % RH 1.3 % RH 2.0 % RH Vaisala MI70/HMP77B Relative Humidity3 – Measuring Equipment 11 % RH 75 % RH 97 % RH 1.6 % RH 2.0 % RH 2.6 % RH Humidity calibrator w/reference salt solutions VI. Time & Frequency Parameter/Equipment Range CMC2, 7 (±) Comments Frequency3 – Measure (1 to 10) Hz 10 Hz to 3 GHz (3 to 26.5) GHz 0.16 mHz/Hz + 1.7 mHz 11 pHzHz/Hz + 2.9 mHz 0.27 pHz/Hz + 1.2 Hz Datum 9390 GPS w/ HP 53132A Opt. 030 Datum 9390 GPS w/ HP 5350B Frequency3 – Measuring Equipment DC to 10 Hz 10 Hz to 80 MHz 80 MHz to 3 GHz (3 to 50) GHz 0.16 mHz/Hz + 1.7 mHz 67 pHz/Hz + 1.8 mHz 8.8 pHz/Hz + 9.0 mHz 0.27 pHz/Hz + 1.2 Hz Datum 9390 GPS w/Keysight 33250A Datum 9390 GPS w/Keysight 83650B Stopwatches/Timers Up to 24 hours 39 ms/d Totalize method using generator and counter ______________________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavio r of the customer’s device and to influences from the circumstances of the specific calibration.
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3270.01) REVISED 10/29/2024 Page 14 of 14 3 Field calibration service is available for this calibration and this laboratory meets A2LA R104 – General Requirements: Accreditation of Field Testing and Field Calibration Laboratories for these calibrations. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, percentages are to be read as percent of reading unless otherwise noted. 5 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 6 This scope meets A2LA’s P112 Flexible Scope Policy. 7 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 8 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches. 9 In the statement of CMC, T is the absolute, numerical value of the nominal temperature of the device measured in degrees Celsius.
15ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1485 Poinsettia Ave., Suite 115, Vista, CA, 92081, US

33.20213, -117.24248

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.