Chief Constable of Essex Police
Essex Police Headquarters, Sandford Road, CM1 6DN, Chelmsford, United Kingdom
Visit website- Scope lines
- 12
- UKAS certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 12 scope lines.
UKAS certificate 7888 · 12 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017 | - | - |
| 2 | ISO/IEC 17025:2017 | - | - |
| 3 | ISO/IEC 17025:2017 | Blood | - |
| 4 | ISO/IEC 17025:2017; Forensic Science Regulator Code of Practice V2 FSA Specific Requirements | water | - |
| 5 | - | Fingermarks; Any material which is capable of retaining friction ridge marksShow page textExtracted from the scope document; tables may not line up. View scope for the original. 7888
Accredited to
ISO/IEC 17025:2017
Schedule of Accreditation
issued by
United Kingdom Accreditation Service
2 Pin e Tre e s, Ch e rts ey La n e , Sta ine s -u po n-Tha me s , TW18 3 HR, UK
Chief Constable of Essex Police
Issue No: 043 Issue date: 01 October 2025
Testing performed by the Organisation at the locations specified
Assessment Manager: ZR Page 5 of 12
Materials/Products tested
Type of test/Properties
measured/Range of
measurement
Standard specifications/
Equipment/Techniques used
Location
Code
MARKS AND IMPRESSIONS
(cont’d)
Forensic Analysis (cont’d) The organisation has
demonstrated compliance to
the Forensic Science
Regulator Code of Practice
V2 FSA Specific
Requirements:
• Friction Ridge Detail:
visualisation and
enhancement
Fingermarks
Any material which is capable of
retaining friction ridge marks
(cont’d)
Enhancement of fingermarks,
palm marks and plantar marks
(cont’d)
Documented In-House
Methods using visual and
lighting enhancement
techniques
B
- Visual examination
- White Light
(SOPCEL017)
- High Intensity Light
Sources (SOPCEL025 /
026 / 027)
- Crime-Lite 82S
UV (λ=350-380nm)
Blue (λ=420-
470nm)
Green (λ=480-
560nm)
- Laser
Green (λ=532nm)
- Crimelite ML
Blue (λ =420-
470nm)
Documented In-House
Methods for imaging / digital
capture (SOPCEL030 / 046 /
047)
- DCS5 (SOPCEL030)
- Digital SLR
(SOPCEL046 / 047)
B
Developed fingerprint marks Determination of the presence
of friction ridge characteristics
for the purpose of subsequent
comparison
Documented In-House
methods using visual
examination (SOPCEL018)
B | - |
| 6 | ISO/IEC 17025:2017 | Marks; Ten Prints | - |
| 7 | ISO/IEC 17025:2017 | MARKS AND IMPRESSIONS; CSI/FEL Recovered Lifts from physical scenes; CSI/FEL Photographs of marks from physical scene; Fingerprint Enhancement Laboratory Recovered Lifts from physical items; Fingerprint Enhancement Laboratory Photographs of marks from Chem lab from physical items; Ink; Powder | - |
| 8 | ISO/IEC 17025:2017; Forensic Science Regulator Code of Practice V2 FSA Specific Requirements | DIGITAL DEVICES AND DATA; Computers; Computers and digital storage devices; Hard disk drives; Solid state drives; Memory cards | - |
| 9 | ISO/IEC 17025:2017; Forensic Science Regulator Code of Practice V2 FSA Specific Requirements | DIGITAL DEVICES AND DATA; Computers and digital storage devices; Data associated with the following:; operating systems | - |
| 10 | ISO/IEC 17025:2017; Forensic Science Regulator Code of Practice V2 FSA Specific Requirements | DIGITAL DEVICES AND DATA; Computers; Hard disk drives; Solid state drives; Memory cards; USB flash drives; Mobile phones; Mobile phone handsets and tablets | - |
| 11 | ISO/IEC 17025:2017; Forensic Science Regulator Code of Practice V2 FSA Specific Requirements | DIGITAL DEVICES AND DATA; Mobile phones; (U)SIM cards | - |
| 12 | ISO/IEC 17025:2017; Forensic Science Regulator Code of Practice V2 FSA Specific Requirements | DIGITAL DEVICES AND DATA; Mobile phones; Memory cards and associated mobile phone handsets and tablets | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United Kingdom
- LGC LimitedCambridgeshire · ~59 kmUKASShares 1 accredited materialBlood
- Hammersmith Medicines ResearchLondon · ~60 kmUKASShares 1 accredited materialBlood
- Analytical Services International Ltd (ASI)London · ~60 kmUKASShares 1 accredited materialBlood
- Lab Services Ltd (trading as Medivet Labs)Hertfordshire · ~62 kmUKASShares 1 accredited materialBlood
- Kingston University Enterprise Limited trading as Kingston Analytical Services Toxicology (KAST)Kingston · ~68 kmUKASShares 1 accredited materialBlood
Accreditation data refreshed from the UKAS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.