SIMCO Electronics - Denver
389 Disc Dr., 80503, Longmont, CO, United States
Visit website- Scope lines
- 12
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 12 scope lines.
A2LA certificate 1395.24 · 12 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 1 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.24) 11/24/2025 Page 2 of 11
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Voltage – Generate3
Up to 330 mV
330 mV to 3.3 V
(3.3 to 33) V
(33 to 330) V
(330 to 1000) V
16 µV/V + 0.78 µV
9.2 µV/V + 1.6 µV
10 µV/V + 16 µV
15 µV/V + 120 µV
15 µV/V + 1.2 mV
Fluke 5520A
DC Voltage – Measure3
(0 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 1000) V*
11 µV/V + 0.3 µV
5.3 µV/V + 0.3 µV
5.1 µV/V + 0.5 µV
8.5 µV/V + 30 µV
8.9 µV/V + 100 µV*
HP 3458A, opt 2
*add 12 (Vin/1000)2
parts in 106 to all
Vin > 100
DC Current – Generate3
Clamp Meters3
(0 to 330) µA
330 µA to 3.3 mA
(3.3 to 33) mA
(33 to 330) mA
330 mA to 1.1 A
(1.1 to 3) A
(3 to 11) A
(11 to 20) A
(10 to 1000) A
0.012 % + 0.02 µA
79 µA/A + 0.04 µA
79 µA/A + 0.19 µA
80 µA/A + 32 µA
0.016 % + 32 µA
0.030 % + 32 µA
0.040 % + 0.39 mA
0.078 % + 0.59 mA
0.82 % + 0.029 A
Fluke 5520A
Fluke 5500A/coil &
5520A/SC1100
DC Current – Measure3
(10 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(1 to 2) A
(2 to 20) A
(20 to 100) A
0.003 µA/A + 0.8 nA
0.03 µA/A + 5 nA
0.3 µA/A + 50 nA
0.005 mA/A + 500 nA
0.15 mA/A + 10 µA
0.003 A
0.058 A
0.29 A
HP 3458A, opt 2
Current shunt, HP
3458A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.24) 11/24/2025 Page 3 of 11
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Resistance – Generate3
Up to 11 Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
(0.33 to 1.1) kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
(0.33 to 1.1) MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(0.33 to 1.1) GΩ
33 µΩ/Ω + 0.0078 Ω
26 µΩ/Ω + 1.2 mΩ
27 µΩ/Ω + 1.2 mΩ
30 µΩ/Ω + 1.6 mΩ
27 µΩ/Ω + 1.6 mΩ
30 µΩ/Ω + 1.6 mΩ
34 µΩ/Ω + 78 mΩ
27 µΩ/Ω + 0.78 Ω
22 µΩ/Ω + 0.32 Ω
27 µΩ/Ω + 7.8 Ω
30 µΩ/Ω + 7.8 Ω
48 µΩ/Ω + 120 Ω
0.010 % + 200 Ω
0.02 % + 1.9 kΩ
0.039 % + 2.4 kΩ
0.23 % + 78 kΩ
1.2 % + 390 kΩ
Fluke 5520A/SC1100
Resistance – Measure3
(0 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(100 to 1000) MΩ
25 µΩ/Ω + 50 µΩ
21 µΩ/Ω + 0.5 mΩ
12 µΩ/Ω + 0.5 mΩ
12 µΩ/Ω + 50 mΩ
14 µΩ/Ω + 90 mΩ
20 µΩ/Ω + 2 Ω
59 µΩ/Ω + 100 Ω
0.061 % + 1 kΩ
32 % + 10 kΩ
HP 3458A, opt 2
Electrical Simulation of
Thermocouples
Indicating Devices –
Generate & Measure3
Type E
Type J
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
0.42 °C
0.18 °C
0.17 °C
0.18 °C
0.21 °C
0.24 °C
0.18 °C
0.17 °C
0.18 °C
0.22 °C
Fluke 5520A/SC1100 | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.24) 11/24/2025 Page 4 of 11
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
Thermocouples Indicating
Devices – Generate &
Measure
3
(cont)
Type K
Type T
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.28 °C
0.19 °C
0.18 °C
0.24 °C
0.33 °C
0.50 °C
0.22 °C
0.18 °C
0.17 °C
Fluke 5520A/SC1100
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
Capacitance – Generate3
(0.19 to 0.3999) nF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) µF
(1.1 to 3.299 99) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 1.099 99) mF
(1.1 to 3.2999) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
(33 to 110) mF
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 3 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 600 Hz
(10 to 300) Hz
(10 to 150) Hz
(10 to 120) Hz
(10 to 80) Hz
(0 to 50) Hz
(0 to 20) Hz
(0 to 6) Hz
(0 to 2) Hz
(0 to 0.6) Hz
(0 to 0.2) Hz
0.55 % + 7.8 pF
0.44 % + 7.8 pF
0.42 % + 7.8 pF
0.24 % + 7.8 pF
0.23 % + 78 pF
0.24 % + 78 pF
0.24 % + 0.23 nF
0.24 % + 0.8 nF
0.23 % + 2.3 nF
0.24 % + 7.8 nF
0.34 % + 24 nF
0.39 % + 78 nF
0.39 % + 0.24 µF
0.37 % + 0.8 µF
0.37 % + 2.3 µF
0.37 % + 8 µF
0.59 % + 24 µF
0.86 % + 78 µF
Fluke 5520A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.24) 11/24/2025 Page 5 of 11
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Oscilloscope3 –
Amplitude – DC Signal:
50 Ω
1 MΩ
Amplitude – Square
Wave3:
50 Ω
1 MΩ
Bandwidth
Time Marker
Rise Time
1 mV to 6.6 V
1 mV to 130 V
1 mV
p-p to 6.6 Vp-p,
10 Hz to 100 kHz
1 mVp-p to 130 Vp-p,
10 Hz to 100 kHz
5 mV to 5.5 V:
50 kHz
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
4 mV to 3.5 V:
(600 to 1100) MHz
5 s to 50 ms
1 ns to 20 ms
1 kHz to 2 MHz:
(200 to 300) ps
(2 to 10) MHz:
(200 to 350) ps
0.2 % + 40 µV
0.05 % + 40 µV
0.23 % + 31 µV
0.16 % + 31 µV
1.8 % + 0.23 mV
2.8 % + 0.23 mV
3.2 % + 0.23 mV
4.7 % + 0.23 mV
5.5 % + 0.23 mV
60 µs/s
2.1 µs/s
82 ps
82 ps
Fluke 5520A/SC1100 | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.24) 11/24/2025 Page 6 of 11
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Generate3
(1 to 33) mV
(33 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.064 % + 4.7 µV
0.019 % + 4.7 µV
0.023 % + 4.7 µV
0.082 % + 4.7 µV
0.28 % + 9.3 µV
0.63 % + 39 µV
0.024 % + 6.2 µV
0.013 % + 6.2 µV
0.014 % + 6.2 µV
0.029 % + 6.2 µV
0.063 % + 25 µV
0.16 % + 55 µV
0.024 % + 39 µV
0.014 % + 47 µV
0.017 % + 47 µV
0.025 % + 39 µV
0.056 % + 97 µV
0.2 % + 470 µV
0.025 % + 510 µV
0.014 % + 470 µV
0.02 % + 470 µV
0.03 % + 470 µV
0.072 % + 1.3 mV
0.017 % + 1.6 mV
0.017 % + 4.7 mV
0.022 % + 4.7 mV
0.03 % + 4.7 mV
0.17 % + 39 mV
0.025 % + 7.8 mV
0.021 % + 7.8 mV
0.025 % + 7.8 mV
Fluke 5520A/SC1100 | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.24) 11/24/2025 Page 7 of 11
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Measure3
(1 to 10) mV
(10 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
0.05 % + 3 µV
0.037 % + 1.1 µV
0.048 % + 1.1 µV
0.12 % + 1.1 µV
0.61 % + 1.1 µV
4.7 % + 2 µV
110 µV/V + 4 µV
91 µV/V + 2 µV
0.017 % + 2 µV
0.036 % + 2 µV
0.096 % + 2 µV
0.76 % + 10 µV
1.2 % + 10 µV
83 µV/V + 40 µV
84 µV/V + 20 µV
0.016 % + 20 µV
0.035 % + 20 µV
0.093 % + 20 µV
0.35 % + 100 µV
1.2 % + 100 µV
85 µV/V + 0.4 mV
84 V/V + 0.2 mV
0.017 % + 0.2 mV
0.035 % + 0.2 mV
0.093 % + 0.2 mV
0.35 % + 1.0 mV
1.2 % + 1.0 mV
0.02 % + 4 mV
0.01 % + 2 mV
0.024 % + 2.5 mV
0.041 % + 2.5 mV
0.14 % + 2.5 mV
0.05 % + 40 mV
0.05 % + 20 mV
0.07 % + 20 mV
0.14 % + 20 mV
0.35 % + 20 mV
HP 3458A, opt 2 | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.24) 11/24/2025 Page 8 of 11
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Generate3
(29 to 330) µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 1.1) A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1.0 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1.0 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1.0 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1.0 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1.0 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1.0 kHz
(1 to 5) kHz
(5 to 10) kHz
45 Hz to 1.0 kHz
(1 to 5) kHz
45 Hz to 1.0 kHz
(1 to 5) kHz
0.16 % + 80 nA
0.12 % + 80 nA
0.1 % + 80 nA
0.23 % + 0.12 µA
0.62 % + 0.16 µA
1.3 % + 0.31 µA
0.16 % + 0.12 µA
0.1 % + 0.12 µA
0.08 % + 0.12 µA
0.16 % + 0.16 µA
0.39 % + 0.23 µA
0.8 % + 0.47 µA
0.14 % + 1.6 µA
0.071 % + 1.6 µA
0.034 % + 1.6 µA
0.064 % + 1.6 µA
0.16 % + 2.4 µA
0.32 % + 3.1 µA
0.14 % + 16 µA
0.071 % + 16 µA
0.034 % + 16 µA
0.079 % + 39 µA
0.16 % + 78 µA
0.32 % + 0.16 mA
0.14 % + 78 µA
0.039 % + 78 µA
0.039 % + 78 µA
0.47 % + 0.78 mA
2.0 % + 4 mA
0.14 % + 78 µA
0.15 % + 78 µA
0.055 % + 78 µA
0.47 % + 0.78 mA
2.0 % + 4 mA
0.083 % + 1.6 mA
2.4 % + 1.6 mA
0.12 % + 4 mA
2.4 % + 4 mA
Fluke 5520A/SC1100 | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.24) 11/24/2025 Page 9 of 11
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Generate3
(cont)
Clamp Meters:
Up to 500 A
(500 to 1000) A
(45 to 440) Hz
(45 to 440) Hz
1.2 % + 0.078 A
1.2 % + 0.19 A
Fluke 5500A/coil &
5520A LCOMP OFF
AC Current – Measure3
(5 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(1 to 2) A
(2 to 20) A*
(20 to 200) A*
45 Hz to 5 kHz
45 Hz to 5 kHz
45 Hz to 5 kHz
45 Hz to 5 kHz
45 Hz to 5 kHz
45 Hz to 1 kHz
45 Hz to 1 kHz
45 Hz to 1 kHz
0.07 % + 0.03 µA
0.07 % + 0.2 µA
0.07 % + 2 µA
0.07 % + 20 µA
0.12 % + 0.2 mA
0.14 % + 0.2 mA
0.17 % + 2 mA
0.17 % + 2 mA
HP 3458A, opt2
* w/ Valhalla 2575A
III. Mechanical
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Torque –Measure,
Wrenches & Drivers3
(5 to 50) ozf∙in
(5 to 25) lbf∙in
(25 to 250) lbf∙in
(25 to 250) lbf∙ft
0.77 % Indicated Value
0.77 % Indicated Value
0.77 % Indicated Value
0.77 % Indicated Value
Check-line ITI &
ITF-System | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.24) 11/24/2025 Page 10 of 11
IV. Time & Frequency
Parameter/Equipment
Range
CMC2, 5, 7 (±)
Comments
Frequency – Generate
Equipment3
Rubidium Standard
10 MHz
Up to 80 MHz
Up to 26.5 GHz
(1 x 10
-9) Hz + 0.58R
(1 x 10
-9) Hz + 1 µHz
(1.2 x 10-9) Hz + 0.58R
Pendulum Instruments
GPS-12R
Rubidium, Agilent
33120A & 83630B
Frequency – Measure3
Up to 12.4 GHz
(1 x 10-9) Hz + 0.58R
Rubidium, Agilent
53132A, HP53131A
Tachometers –
Noncontact
3
(10 to 200 000) rpm
0.19 mrpm/rpm + 0.58R
HP 33250A phase
locked to GPS-12R
_______________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent
or fraction of the reading plus a fixed floor specification.
5 In the statement of CMC, R is the resolution of the unit under test; L is the numerical value of the nominal
length of the device measured in inches. In the statement of CMC, the value is defined as the percentage
of reading.
6 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.24) 11/24/2025 Page 11 of 11
7 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 12 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- BHD Test & MeasurementThornton, CO · ~35 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Colorado Engineering Experiment Station,Nunn, CO · ~66 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Technical Maintenance, Inc. - COLORADO SPRINGSColorado Springs, CO · ~150 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - Salt Lake CityDraper, UT · ~574 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Western States CalibrationSalt Lake City, UT · ~578 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.