Registers refreshed 2026-11-08.See refresh dates
Poland

SONIC-LAB Sp. z o.o.

ul. Chabrowa 5, 06-400, Ciechanów, Poland

PCA AB 1958ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
2
PCA certificate
1
Site in our directory
1
PCA accredited scope

What this lab is accredited for

Our reading of the PCA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 2 standard numbers and the 2 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO 9612Acoustics - Determination of occupational noise exposure - Methodology
PN-N-01307:1994Hałas - Dopuszczalne wartości hałasu w środowisku pracy - Wymagania dotyczące wykonywania pomiarów

Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-06.

Scope as published by PCA

2 lines
PCA

ISO/IEC 17025

Active

AB 1958

The scope document we hold says it is valid until 2030-02-19.

View on PCA

Accredited scope, certificate AB 1958

LineMethodMatrixRange
1-workplace (harmful and nuisance factors – noise); general environment (physical factors – noise)
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

PCA Zakres akredytacji Nr AB 1958 Scope of accreditation No AB 1958 ZAKRES AKREDYTACJI LABORATORIUM BADAWCZEGO SCOPE OF ACCREDITATION FOR TESTING LABORATORY Nr/No AB 1958 wydany przez / issued by POLSKIE CENTRUM AKREDYTACJI 01-382 Warszawa, ul. Szczotkarska 42 Wydanie/Issue 1 z/of 20 lutego 2026 r. KIEROWNIK DZIAŁU AKREDYTACJI BADAŃ EMISJI W ŚRODOWISKU MAR CIN BEKA S Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 1958 z dnia 20.02.2026 r. Cykl akredytacji od 20.02.2026 r. do 19.02.2030 r. Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl This document is an annex to accreditation certificate No AB 1958 of 20.02.2026 Accreditation cycle from 20.02.2026 to 19.02.2030 The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl Wydanie nr / Issue No 1, 20.02.2026 str. 1/3 Nazwa i adres / Name and address SONIC-LAB Sp. z o.o. Kuklin 10B 06-513 Wieczfnia Kościelna BIURO TERENOWE ul. Chabrowa 5 06-400 Ciechanów Kod identyfikacyjny / Identification code *) Dziedzina i przedmiot badań / Field of testing and item: - G/33, G/34 - Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas), środowisko ogólne (czynniki fizyczne – hałas) / Test concerning environmental engineering (enviromental and climatic) – workplace (harmful and nuisance factors – noise), general environment (physical factors – noise) Wersja strony/Page version: A *) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl / The identification code according to the Annex to document DAB-07, available at PCA website www.pca.gov.pl AB 1958
-
2PN-N-01307:1994; PN-EN ISO 9612:2011; Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706)Workplace environment25 to 137 dB

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

ul. Chabrowa 5, Ciechanów, 06-400, PL

52.87120, 20.60625

Open in Maps

Accreditation data refreshed from the PCA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.