Registers refreshed 2026-11-08.See refresh dates
Taiwan

International Standards

No. 120, Lane 180, Hsin Ho Rd., Lung-Tan Dist., Tao Yuan City, 32544, Republic of China Taiwan, Tao Yuan City, Taiwan

Visit website
A2LA 4303.02ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
30
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 30 standard numbers and the 28 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 61000 series12
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection
IEC 61000-3-12Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase

Certificate says EN 61000-3-12. Probably the same standard; not checked against the EN document.

IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-34
ISO 11452 series7
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-3Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 3: Transverse electromagnetic (TEM) cell
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
ISO 11452-5Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 5: Stripline
ISO 11452-7Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 7: Direct radio frequency (RF) power injection
ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fields
ISO 11452-9Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 9: Portable transmitters
CISPR3
CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement

Certificate says EN 55024. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements

Certificate says EN 55035. Probably the same standard; not checked against the EN document.

ISO 7637 series3
ISO 7637-1Road vehicles - Electrical disturbances from conduction and coupling - Part 1: Vocabulary and general considerations
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
Other standards5
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
FCC PART 15Radio Frequency Devices
ICES-003
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Active

4303.02

The scope document we hold says it was valid until 2026-06-30. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 4303.02

LineMethodMatrixRange
147 CFR, FCC Part 15 Subpart B (using ANSI C63.4:20141); ANSI C63.41; ICES-003; IEC/CISPR 32; EN 55032; BS EN 55032; IEC 61000-3-2; EN 61000-3-2; EN IEC 61000-3-2; BS EN IEC 61000-3-2; IEC 61000-3-12; EN 61000-3-12; BS EN 61000-3-12; IEC 61000-3-3; EN 61000-3-3; BS EN 61000-3-3; IEC 61000-3-11; EN 61000-3-11; BS EN 61000-3-11; EN IEC 61000-3-11; IEC 61000-4-2; EN 61000-4-2; BS EN 61000-4-2; IEC 61000-4-3; EN 61000-4-3; EN IEC 61000-4-3; BS EN 61000-4-3; BS EN IEC 61000-4-3; IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-4; IEC 61000-4-5; EN 61000-4-5; BS EN 61000-4-5; IEC 61000-4-6; EN 61000-4-6; BS EN 61000-4-6-to 40 GHz
2IEC 61000-4-8; EN 61000-4-8; BS EN 61000-4-8; IEC 61000-4-11; EN 61000-4-11; EN IEC 61000-4-11; BS EN 61000-4-11; BS EN IEC 61000-4-11; IEC 61000-4-34; EN 61000-4-34; BS EN 61000-4-34; CISPR 24; EN 55024; BS EN 55024; CISPR 35; EN 55035; BS EN 55035; CISPR 25; ISO 11452-2; ISO 11452-3; ISO 11452-4; ISO 11452-5; ISO 11452-7; ISO 11452-8; ISO 11452-9; ISO 7637-1; ISO 7637-2; ISO 7637-3; ISO 16750-2; ISO 10605-to 6 GHz
3ANSI C63.4a:2017; ANSI C63.4:2014--
4

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited INTERNATIONAL STANDARDS LABORATORY CORP. Tao Yuan City, Taiwan (R.O.C.) for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 10th day of April 2024. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 4303.02 Valid to June 30, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.