TUV SUD Japan
Tokyo Testing Center, NF Park Bldg. 2-9-15, Futaba, Shinagawa-ku, Tokyo, 142-0043, Japan, Tokyo, Japan
Visit website- Accredited standards
- 40
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 40 standard numbers and the 10 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 60601 series22
IEC 60601-1Medical electrical equipment - Part 1: General requirements for basic safety and essential performanceExclusion
Limits written next to it
EN 60601-1:2006 (Excluding Sections 8.8.4.2, 8.9.1.7, 9.5.2
EN 60601-1:2006 + A1:2013(Excluding Sections 8.8.4.2, 8.9.1.7
IEC 60601-1:2005 (Excluding Sections 8.8.4.2, 8.9.1.7, 9.5.2
IEC 60601-1:2005 + A1:2012 (Excluding Sections 8.8.4.2, 8.9.1.7
IEC 60601-1:2005 + A1:2012 + A2:2020 (Excluding Sections
IEC 60601-1-1
IEC 60601-1-6
IEC 60601-1-8
IEC 60601-1-11Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environmentExclusion
Limits written next to it
EN 60601-1-11:2010 (Excluding Sections 4.2, 10.1, 12)
IEC 60601-1-11:2010 (Excluding Sections 4.2, 10.1, 12)
IEC 60601-1-11:2015 (Excluding Sections 4.2, 10.1, 12)
IEC 60601-1-11:2015/AMD1:2020 (Excluding Sections 4.2, 10.1
IEC 60601-1-12Exclusion
Limits written next to it
IEC 60601-1-12:2014 (Excluding sections 10.1.2, 10.1.3, 10.1.4)
IEC 60601-1-12:2014/AMD1:2020(Excluding sections 10.1.2
IEC 60601-2-5Some clauses
Limits written next to it
EN 60601-2-5:2000 (Only Sections 35, 50, 51.5, 51.104)
IEC 60601-2-5:2000 (Only Sections, 50, 51.5, 51.104)
IEC 60601-2-5:2009 (Only Sections 201.10.102, 201.12.1
IEC 60601-2-16Exclusion
Limits written next to it
EN 60601-2-16:1015 (Excluding Section 201.12.4.4.101)
EN 60601-2-16:1019 (Excluding Section 201.12.4.4.101)
EN 60601-2-16:1998 (Excluding Section 19.4)
IEC 60601-2-16:1998 (Excluding Section 19.4)
IEC 60601-2-16:2008 (Excluding Section 201.12.4.4.101)
IEC 60601-2-16:2012 (Excluding Section 201.12.4.4.101)
IEC 60601-2-16:2018 (Excluding Section 201.12.4.4.101)
IEC 60601-2-18
IEC 60601-2-19Exclusion
Limits written next to it
EN 60601-2-19: 2009 + A1:2016 (Excluding Sections 201.11.1.2
IEC 60601-2-19:2009 + A1:2016 (Excluding Sections 201.11.1.2
IEC 60601-2-19:2020+A1:2023 (Excluding Sections 201.11.1.2
IEC 60601-2-20Exclusion
Limits written next to it
EN 60601-2-20: 2009 + A1:2016 (Excluding Sections 201.11.1.2
EN 60601-2-20:2009 (Excluding Sections 201.11.1.2
IEC 60601-2-20: 2009 (Excluding Sections 201.11.1.2
IEC 60601-2-20: 2009 + A1: 2016 (Excluding Sections
IEC 60601-2-20:1990 + A1:1996 (Excluding Sections 43.103
IEC 60601-2-20:2020+A1:2023 (Excluding Sections 201.11.1.2
IEC 60601-2-21Exclusion
Limits written next to it
EN 60601-2-21:2009 (Excluding Sections 201.12.1.110
EN 60601-2-21:2009 + A1:2016 (Excluding Sections
IEC 60601-2-21:1990 + A1:1996 (Excluding Section 43.103)
IEC 60601-2-21:2009 (Excluding Sections 201.12.1.110
IEC 60601-2-21:2009 + A1:2016 (Excluding Sections
IEC 60601-2-21:2020+A1:2023(Excluding Sections 201.12.1.110
Show all 22
IEC 60601-2-22
IEC 60601-2-25Exclusion
Limits written next to it
EN 60601-2-25:2015 (Excluding Section 202)
IEC 60601-2-25:2011 (Excluding Section 202)
IEC 60601-2-26
IEC 60601-2-27Exclusion
Limits written next to it
EN 60601-2-27:2006 (Excluding Section 36)
IEC 60601-2-27:1994 (Excluding Section 36)
IEC 60601-2-27:2005 (Excluding Section 36)
IEC 60601-2-27:2011 (Excluding Section 202.6)
IEC 60601-2-30Exclusion
Limits written next to it
EN 60601-2-30:2000 (Excluding Sections 201.106, 202.6.2.102)
IEC 60601-2-30:1999 (Excluding Sections 201.106, 202.6.2.102)
IEC 60601-2-37ExclusionSome clauses
Limits written next to it
EN 60601-2-37:2008 (Excluding Section 202)
IEC 60601-2-37:2007 (Excluding Section 202)
IEC 60601-2-37:2007 + A1:2015 (Excluding Section 202)
IEC 60601-2-37:2024 (Excluding Section 202)
EN 60601-2-37:2008 (Only Sections 201.7.9.3, 201.11.1.3)
IEC 60601-2-37:2001 + A1:2004 + A2:2005 (Only Sections 35
IEC 60601-2-37:2007 (Only Sections 201.7.9.3, 201.11.1.3)
IEC 60601-2-37:2007 + A1:2015 (Only Sections 201.7.9.3
IEC 60601-2-37:2024 (Only Sections 201.7.9.3, 201.11.1.3
IEC 60601-2-39
IEC 60601-2-47
IEC 60601-2-49Exclusion
Limits written next to it
EN 60601-2-49:2001 (Excluding Section 202)
IEC 60601-2-49:2001 (Excluding Section 202)
IEC 60601-2-49:2011 (Excluding Section 202)
IEC 60601-2-50
IEC 61010 series6
IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirementsExclusionSome clauses
Limits written next to it
EN 61010-1:2010 (Excluding Sections 6.7.1.3, 10.5.3_2), 12.2.1
EN 61010-1:2010 + A1:2019 (Excluding Sections 6.7.1.3
IEC 61010-1:2001 (Excluding Sections 6.7.1.2, 10.5.3_2), 12.2.1
IEC 61010-1:2010 (Excluding Sections 6.7.1.3, 10.5.3_2), 12.2.1
IEC 61010-1:2010 + A1:2016 (Excluding Sections 6.7.1.3
EN 61010-1:2010 (Only sections 4.4, 5.1.3, 5.3, 6.2, 6.3, 6.5.2
IEC 61010-1:2010 (Only sections 4.4, 5.1.3, 5.3, 6.2, 6.3, 6.5.2
IEC 61010-2-010
IEC 61010-2-020
IEC 61010-2-040Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
IEC 61010-2-081
IEC 61010-2-101Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipmentSome clauses
Limits written next to it
EN 61010-2-101:2002 (Only Section 5.3)
EN 61010-2-101:2017 (Only Section 5.3)
IEC 61010-2-101:2002 (Only Section 5.3)
IEC 61010-2-101:2015 (Only Section 5.3)
IEC 61010-2-101:2018 (Only Section 5.3)
IEC5
IEC 60825-1Exclusion
Limits written next to it
EN 60825-1:2007 (Excluding Section 9.3.3_b)
EN 60825-1:2014 (Excluding Section 5.4.3_b)
IEC 60825-1:2007 (Excluding Section 9.3.3_b)
IEC 60825-1:2014 (Excluding Section 5.4.3_b)
IEC 62366
IEC 62471Photobiological safety of lamps and lamp systemsExclusion
Limits written next to it
Lamps and lamp systems IEC 62471:2006 (Excluding Section 4.3.1)
IEC 80601-2-30Medical electrical equipment - Part 2-30: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometersExclusion
Limits written next to it
IEC 80601-2-30:2009 (Excluding Sections 201.106, 202.6.2.102)
IEC 80601-2-30:2009 + A1:2013 (Excluding Sections 201.106
IEC 80601-2-30:2018 (Excluding Sections 201.106, 202.6.2.102)
IEC 80601-2-60
EN 18031 series3
EN 18031-1
EN 18031-2
EN 18031-3
ISO3
ISO 8185Respiratory tract humidifiers for medical use - Particular requirements for respiratory humidification systemsExclusion
Limits written next to it
ISO 8185:1997 (Excluding Sections 36, 43, 56.12)
ISO 8185:2007 (Excluding Sections 36, 43.101, 56.101)
ISO 80601-2-61Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipmentExclusion
Limits written next to it
ISO 80601-2-61:2011 (Excluding Sections 201.12.1.101
ISO 80601-2-61:2017 (Excluding Sections 201.12.1.101
ISO 80601-2-74Medical electrical equipment - Part 2-74: Particular requirements for basic safety and essential performance of respiratory humidifying equipmentExclusion
Limits written next to it
ISO 80601-2-74:2017 (Excluding Section 202)
ISO 80601-2-74:2021 (Excluding Section 202)
Other standards1
ETSI TS 103 701
EN 61010-2-081:2015; IEC61010-2-081:2019; CAN/CSA-C22.2 No. 61010-2-081:19; IEC 61010-2-101:2002; EN 61010-2-101:2002; IEC 61010-2-101:2015; EN 61010-2-101:2017; JIS C 61010-2-101:2017; IEC 61010-2-101:2018; CAN/CSA-C22.2 No. 61010-2-101:19; IEC 61010-1:2010; EN 61010-1:2010; JIS C 1010-1:2014; IEC 61010-2-101:2002; EN 61010-2-101:2002; IEC 61010-2-101:2015; IEC 61010-2-101:2018; EN 61010-2-101:2017; JIS C 61010-2-101:2017; CAN/CSA-C22.2 No. 61010-2-101:19; IEC 60601-1:1988 + A1:1991 + A2:1995; JIS T 0601-1:1999; IEC 60601-1:2005; EN 60601-1:2006; JIS T 0601-1:2012; IEC 60601-1:2005 + A1:2012
IEC 60601-2-49:2001; EN 60601-2-49:2001; IEC 60601-2-49:2011; CAN/CSA-C22.2 No. 60601-2-49:11; IEC 60601-2-50:2000; IEC 60601-2-50:2009; EN 60601-2-50:2009; IEC 60601-2-50:2020; CAN/CSA-C22.2 No. 60601-2-50:23; IEC 62366:2007; IEC 62366:2007 + A1:2014; EN 62366:2008; ISO 80601-2-61:2011; JIS T 80601-2-61:2014; ISO 80601-2-61:2017; CSA-C22.2 No. 80601-2-61:21; ISO 8185:1997; JIS T 7207:2005; ISO 8185:2007; IEC 60601-1:2005; EN 60601-1:2006; JIS T 0601-1:2012; IEC 60601-1:2005 + A1:2012; EN 60601-1:2006 + A1:2013
ANSI/AAMI ES 60601-1:2005® 2012; CAN/CSA-C22.2 No. 60601-1:14; JIS T 0601-1:2014; IEC 60601-1:2005 + A1:2012 + A2:2020; ANSI/AAMI ES60601-1:2005/(R)2012 & A1:2012 & A2:2021; IEC 60601-2-18:1996 + A1:2000; IEC 60601-2-18:2009; EN 60601-2-18:1996 + A1:2000; JIS T 0601-2-18:2005; JIS T 0601-2-18:2013; CAN/CSA-C22.2 No. 60601-2-18:11 (R2021); IEC 60601-2-5:2000; EN 60601-2-5:2000; JIS T 0601-2-5:2005; IEC 60601-2-5:2009; JIS T 0601-2-5:2015; CAN/CSA-C22.2 No. 60601-2-5:11 (R2021); IEC 60601-2-16:1998; EN 60601-2-16:1998; JIS T 0601-2-16:2008; IEC 60601-2-16:2008; IEC 60601-2-16:2012
EN 60601-1:2006 + A1:2013; ANSI/AAMI ES60601-1:2005(R) 2012; CAN/CSA-C22.2 No. 60601-1:14; JIS T 0601-1:2014; IEC 60601-1:2005 + A1:2012 + A2:2020; ANSI/AAMI ES60601-1:2005/(R)2012 & A1:2012 & A2:2021; IEC 60601-1-1:2000; JIS T 0601-1-1:2005; IEC 60601-1-6:2004; IEC 60601-1-6:2010; IEC 60601-1-6:2010 + A1:2013; EN 60601-1-6:2010; EN 60601-1-6:2010/A1:2015; IEC 60601-1-8:2003 + A1:2006; IEC 60601-1-8:2006; IEC 60601-1-8:2006 + A1:2012 + A2:2020; EN 60601-1-8:2007 + A1:2013 + A2: 2021; JIS T 60601-1-8:2012; IEC 60601-1-11:2010; IEC 60601-1-11:2015; IEC 60601-1-11:2015/AMD1:2020; EN 60601-1-11:2010; IEC 60601-1-12:2014; IEC 60601-1-12:2014/AMD1:2020
IEC 60601-2-19:2009 + A1:2016; EN 60601-2-19: 2009 + A1:2016; IEC 60601-2-19:2020+A1:2023; CAN/CSA-C22.2 No. 60601-2-19:23; IEC 60601-2-20:1990 + A1:1996; IEC 60601-2-20: 2009; EN 60601-2-20:2009; IEC 60601-2-20: 2009 + A1: 2016; EN 60601-2-20: 2009 + A1:2016; IEC 60601-2-20:2020+A1:2023; CAN/CSA-C22.2 No. 60601-2-20:23; IEC 60601-2-21:1990 + A1:1996; JIS T 0601-2-21:2005; IEC 60601-2-21:2009; EN 60601-2-21:2009; IEC 60601-2-21:2009 + A1:2016; EN 60601-2-21:2009 + A1:2016; JIS T 0601-2-21:2019; IEC 60601-2-21:2020+A1:2023; CAN/CSA-C22.2 No. 60601-2-21:23; IEC 60601-2-22:1995; EN 60601-2-22:1996; IEC 60601-2-22:2007; IEC 60601-2-22:2007 + A1:2012; IEC 60601-2-22:2019; CAN/CSA-C22.2 No. 60601-2-22:23; IEC 60601-2-25:2011; EN 60601-2-25:2015; JIS T 0601-2-25:2014
IEC 60601-2-26:2002; EN 60601-2-26:2003; IEC 60601-2-26:2012; IEC 60601-2-27:1994; IEC 60601-2-27:2005; EN 60601-2-27:2006; IEC 60601-2-27:2011; CAN/CSA-C22.2 No. 60601-2-27:11 (R2021); IEC 60601-2-30:1999; EN 60601-2-30:2000; IEC 80601-2-30:2009; IEC 80601-2-30:2009 + A1:2013; IEC 80601-2-30:2018; CAN/CSA-C22.2 No. 80601-2-30:19; IEC 80601-2-60:2012; IEC 80601-2-60:2019; CAN/CSA-C22.2 No. 80601-2-60:23; ISO 80601-2-74:2017; ISO 80601-2-74:2021; C22.2 No. 80601-2-74:23; IEC 60601-2-37:2001 + A1:2004 + A2:2005; JIS T 0601-2-37:2005; IEC 60601-2-37:2007; IEC 60601-2-37:2007 + A1:2015; EN 60601-2-37:2008; JIS T 0601-2-37:2013; IEC 60601-2-37:2024; CAN/CSA-C22.2 No. 60601-2-37:08 (R2023); IEC 60601-2-39:2007; EN 60601-2-39:2008; JIS T 0601-2-39:2013; IEC 60601-2-47:2001; EN 60601-2-47:2001; IEC 60601-2-47:2012; JIS T 60601-2-47: 2018; CAN/CSA-C22.2 No. 60601-2-47:14 (R2023)
IEC 60601-2-37:2001 + A1:2004 + A2:2005; JIS T 0601-2-37:2005; IEC 60601-2-37:2007; IEC 60601-2-37:2007 + A1:2015; EN 60601-2-37:2008; JIS T 0601-2-37:2013; IEC 60601-2-37:2024; CAN/CSA-C22.2 No. 60601-2-37:08 (R2023); IEC 80601-2-60:2012; IEC 80601-2-60:2019; CAN/CSA-C22.2 No. 80601-2-60:23; ISO 80601-2-74:2017; ISO 80601-2-74:2021; C22.2 No. 80601-2-74:23; IEC 60825-1:1993 + A1:1997 + A2:2001; IEC 60825-1:2007; EN 60825-1:2007; JIS C 6802:2011; IEC 60825-1:2014; JIS C 6802:2014; EN 60825-1:2014; CAN/CSA-E60825-1:15 (R2020); IEC 62471:2006; CAN/CSA-C22.2 No. 62471-12 (R2022); JIS C 7550:2011
IEC 61010-1:2001; JIS C 1010-1:2005; IEC 61010-1:2010; EN 61010-1:2010; JIS C 1010-1:2014; IEC 61010-1:2010 + A1:2016; EN 61010-1:2010 + A1:2019; JIS C 1010-1:2014 + A1:2019; IEC 61010-2-010:2003; EN 61010-2-010:2003; IEC 61010-2-010:2014; EN 61010-2-010:2014; IEC61010-2-010:2019; CAN/CSA-C22.2 No. 61010-2-010:19; IEC 61010-2-020:2006; IEC 61010-2-040:2005; IEC 61010-2-040:2015; IEC 61010-2-081:2001 + A1:2003; EN 61010-2-081:2002 + A1:2003; IEC61010-2-081:2015
EN 18031-1; EN 18031-2; EN 18031-3; TS 103 701
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
11 lines
ISO/IEC 17025
Active3686.01
The scope document we hold says it is valid until 2027-02-28.
Location
Tokyo Testing Center, NF Park Bldg. 2-9-15, Futaba, Shinagawa-ku, Tokyo, 142-0043, Japan, Tokyo, JP
35.67686, 139.76389
Open in MapsLabs with overlapping accredited scope in Japan
- Japan Quality Assurance OrganizationTokyo 192-0364 · ~19 kmA2LAShares 1 accredited materialMeasuring Equipment
- UL Japan, Inc., Shonan EMCKanagawa · ~44 kmA2LAShares 1 accredited materialMedical equipment, electrical safety and EMC
- UL JapanIse-shi, Mie · ~306 kmA2LAShares 1 accredited materialMedical equipment, electrical safety and EMC
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.