SOWIX Sp. z o.o.
ul. Żeromskiego 4A, 21-400, Łuków, Poland
- Accredited standards
- 20
- PCA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the PCA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 20 standard numbers and the 9 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO6
ISO 5349-1Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 1: General requirements
ISO 5349-2Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 2: Practical guidance for measurement at the workplace
ISO 7243Ergonomics of the thermal environment - Assessment of heat stress using the WBGT (wet bulb globe temperature) index
ISO 7730Ergonomics of the thermal environment - Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria
ISO 9612Acoustics - Determination of occupational noise exposure - Methodology
ISO 11079Ergonomics of the thermal environment - Determination and interpretation of cold stress when using required clothing insulation (IREQ) and local cooling effects
Other standards14
EN 1838
EN 14253Mechanical vibration - Measurement and evaluation of occupational exposure to whole-body vibration with reference to health - Practical guidance
PN-N-01307:1994Hałas - Dopuszczalne wartości hałasu w środowisku pracy - Wymagania dotyczące wykonywania pomiarów
PN-Z-04008-7:2002+Az1:2004
PN-Z-04009-11:2008
PN-Z-04041
PN-Z-04045-02
PN-Z-04450
PN-Z-04469
PN-Z-04472
PN-Z-04487
PN-Z-04502
PN-Z-04507:2022-05Ochrona czystości powietrza - Oznaczanie frakcji wdychalnej aerozolu na stanowiskach pracy metodą grawimetryczną
PN-Z-04508:2022-05
PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004+A1:2015-11; Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706); PN-87/B-02156
PN-N-01307:1994; PN-EN ISO 9612:2011; PN-EN ISO 7243:2018-01; PN-EN ISO 11079:2008; PN-EN ISO 7730:2006; PN-83/E-04040.03
PN-EN 1838:2013-11; PN-EN 14253+A1:2011
PN-Z-04008-7:2002+Az1:2004; PN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08
PB P-05 wydanie 4 z dnia 21.01.2021 r.; Podstawy i Metody Oceny Środowiska Pracy 2018, nr 2 (96), str. 133-143; Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130; PN-Z-04009-11:2008
PN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08; PB P-03 wydanie 6 z dnia 15.11.2024 r.; PN-Z-04041:1971; PN-Z-04045-02:1976; PN-Z-04487:2017-10; PN-Z-04469:2015-10; PB P-06, wydanie nr 1 z dnia 20.11.2019 r.
PN-Z-04472:2015-10+Ap1:2015-12; PN-Z-04450:2014-08; PN-Z-04502:2019-10
Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-06.
Scope as published by PCA
9 lines
ISO/IEC 17025
ActiveAB 1024
The scope document we hold says it is valid until 2029-03-25.
Location
Labs with overlapping accredited scope in Poland
- Laboratorium Badań i Pomiarów Środowiska EKOLAB Spółka Cywilna Janusz Michalak, Grażyna Felisiak, Anna WysockaŁódź · ~200 kmPCAShares 7 accredited methods and materialsPN-N-01307:1994PN-Z-04008-7:2002+Az1:2004PN-Z-04009-11:2008
- LAB-SERWIS Laboratorium Badań Środowiska S.C. Artur Kała, Tomasz Polak, Leszek SierocińskiCzęstochowa · ~257 kmPCAShares 7 accredited methods and materialsEN ISO 5349-1:2004PN-N-01307:1994PN-Z-04009-11:2008
- Zakład Usług Technicznych "ZUT" S.C. Bożena i Waldemar SzleperCzęstochowa · ~257 kmPCAShares 7 accredited methods and materialsEN ISO 5349-1:2004PN-Z-04008-7:2002+Az1:2004PN-Z-04009-11:2008
- SBB Laboratorium Badań i EkspertyzKatowice · ~303 kmPCAShares 7 accredited methods and materialsEN ISO 5349-1:2004PN-N-01307:1994PN-Z-04008-7:2002+Az1:2004
- Eurofins SEPO Spółka z ograniczoną odpowiedzialnościąKnurów · ~321 kmPCAShares 7 accredited methods and materialsEN ISO 5349-1:2004PN-N-01307:1994PN-Z-04008-7:2002+Az1:2004
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.