Element Materials Technology Boxborough
1146 Massachusetts Avenue, 01719, Boxborough, MA, United States
Visit website- Accredited standards
- 45
- A2LA certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 45 standard numbers and the 30 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 61000 series17
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test+1 national
National versions in the same scope
KS C 9610-4-2national version with changes
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test+1 national
National versions in the same scope
KS C 9610-4-3national version with changes
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test+1 national
National versions in the same scope
KS C 9610-4-4national version with changes
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity testExclusion
Limits written next to it
EN/IEC 61000-4-5 (excluding 6.2)
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields+1 national
National versions in the same scope
KS C 9610-4-6national version with changes
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase+1 national
National versions in the same scope
KS C 9610-4-11probably the same standard; matched by number only
IEC 61000-4-12Electromagnetic Compatibility (EMC) - Part 4-12: Testing and measurement techniques - Ring wave immunity test+1 national
National versions in the same scope
KS C 9610-4-12probably the same standard; matched by number only
IEC 61000-4-16
IEC 61000-4-29Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
IEC 61000-4-34
Show all 17
IEC 61000-4-39Electromagnetic compatibility (EMC) - Part 4-39: Testing and measurement techniques - Radiated fields in close proximity - Immunity test
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments+1 national
National versions in the same scope
KS C 9610-6-1national version with changes
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments+1 national
National versions in the same scope
KS C 9610-6-2national version with changes
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
CISPR6
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: EmissionExclusion
Limits written next to it
EN 55014-1(excluding disturbance power
EN 55014-1(excluding disturbance power measurements and click measurements)
CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement
CISPR 25Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirementsExclusion+3 national
Limits written next to it
EN 55032(excluding Annex H)
National versions in the same scope
CNS 15936identical to it
KS C 9832national version with changes
VCCI-CISPR 32probably the same standard; matched by number only
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements+1 national
National versions in the same scope
KS C 9835national version with changes
ASTM5
ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
ASTM D635
ASTM D999
ASTM D4169
ASTM G85
ETSI5
ETSI EN 300 019-2-2
ETSI EN 300 132-2
ETSI EN 300 132-3
ETSI EN 300 386Exclusion
Limits written next to it
ETSI EN 300 386 (excluding clause 12.4)
ETSI ETS 300 753
IEC5
IEC 60065-1
IEC 60529Degrees of protection provided by enclosures (IP Code)
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 60695-2-2
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 60068 series3
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-18
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
Other standards4
FCC PART 15Radio Frequency Devices
ICES-003
ISO 7779Acoustics - Measurement of airborne noise emitted by information technology and telecommunications equipment
ISO 20653Road vehicles - Degrees of protection (IP code) - Protection of electrical equipment against foreign objects, water and access
47 CFR, FCC Part 15B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); ICES-003; CISPR 32 (excluding Annex H); EN 55032(excluding Annex H); KS C 9832 (excluding Annex H); CISPR 11; EN 55011; CISPR 14-1 (excluding disturbance power measurements and click measurements); EN 55014-1(excluding disturbance power measurements and click measurements); VCCI V-3 (up to 6 GHz); VCCI-CISPR 32:2016 (excluding Annex H); CNS 15936:2016 (up to 6 GHz); AS/NZ CISPR 32; MIL-STD-4612 C, D (Methods CE01, CE03, RE01, & RE02); MIL-STD-4612 E, F, & G (Methods CE101, CE102, CE106 [up to 18 GHz], RE101, & RE102); MIL-STD-462; MIL-STD-462D; RTCA/DO-1602 C, D, E, F, & G (Section 21); CISPR 25 (clauses 6.3, 6.4, 6.5 only); EN 55025 (clauses 6.3, 6.4, 6.5 only); EN/IEC 61000-3-2; EN/IEC 61000-3-3
IEC/EN 61000-4-2; KS C 9610-4-2; RTCA/DO-1602 D, E, F, & G (Section 25); MIL-STD-1686; MIL-STD-461G (CS118); IEC/EN 61000-4-3; KS C 9610-4-3; RTCA/DO-1602 C, D, E, F, & G (Section 20); MIL-STD-4612 C, D (Methods RS01, RS02, & RS03); MIL-STD-462; MIL-STD-462D; MIL-STD-4612 E, F, & G (Methods RS101 & RS103); MIL-HDBK-240; DoD-STD-1399 Section 70; IEC/EN 61000-4-4; KS C 9610-4-4; EN/IEC 61000-4-5 (excluding 6.2); IEC/EN 61000-4-12; KS C 9610-4-12; RTCA/DO-1602 C, D, E, F & G (Sections 17, 19, & 22); IEC/EN 61000-4-39; IEC/EN 61000-4-6; KS C 9610-4-6; IEC/EN 61000-4-16; RTCA/DO-160 C, D & E (Sections 18 & 20); MIL-STD-4612 C, D (Methods CS01, CS02, & CS06); MIL-STD-462; MIL-STD-462D; MIL-STD-4612 E, F, & G (Methods CS101, CS106, CS109, CS114, CS115, CS116 & CS117); IEC/EN 61000-4-11; KS C 9610-4-11; EN/IEC 61000-4-29; IEC 61000-4-34:2005 + A1:2009; RTCA/DO-1602 C, D, E, F, & G (Section 16); MIL-STD-1399-3002 A & B; MIL-STD-7042 A, B, C, D, E, & F; MIL-STD-1275 B, C, & D; ATIS 0600315; ETSI/EN 300-132-2; ETSI/EN 300-132-3; IEC/EN 61000-6-1; KS C 9610-6-1; IEC/EN 61000-6-2; KS C 9610-6-2; IEC/EN 61000-6-3; IEC/EN 61000-6-4; IEC/EN 60601-1-2; IEC/EN 61326-1; GR-1089-CORE; ETSI EN 300 386 (excluding clause 12.4); ATT-TP-76200; CISPR 24; EN 55024
CISPR 35; EN 55035; KS C 9835; CSA C22.2 No. 1010-1; MIL-STD-740-22; UL 61010A-1; ISO 7779; GR-63-CORE; ETS 300 753; MIL-STD-740-12; ANSI C63.4:2014; FCC MP-5 (February 1986)
ISTA Pre-shipment Test Procedures (1A, 1B, 1C, 1D, 1E, 1G, 1H, 2A, 2B, 2C, 2D, 2E, 3A, 3E, 3F, 3H, 5B, 7B, 7C, 7D, 6-series); ATIS 0600329; IEEE STD 344-2004; IBC 2000; AC156; ETSI 300 019; MIL-STD-202 (Methods 101, 103, 104, 105, 106, 107, 108, 111, 215, 301, 302, 303, 305, 307, & 310); MIL-STD-810 A, B, C, D, E (all changes), F (all notices), G, G(1), H, H(1) (Methods 500, 501, 502, 503, 506, 507, 509, 512, 521); MIL-STD-883C, E(all notices), F, G, H, J(all changes), K(all changes), L (Methods 1001, 1002, 1003, 1004, 1005, 1007, 1008, 1009, 1010, 1011, 1012, & 1013); GR-63-CORE (Sections 4.1.2, 4.1.3); GR-3108-CORE; GR-3160-CORE; RTCA DO-160 B, C, D(all changes), E, F, G, G(1) (Sections 3, 4, 5, 6, 10, 14); IEC 60068; IEC 60068-2-18; ASTM D4169-05, -08, -09, -14, -16, -22, -23e; ASTM B117; ASTM G85-11
GR-63-CORE; ASTM D635; RTCA DO-160 B, C, D(all changes), E, F, G, G(1) (Section 26 for Fire Resistance or Fire Proof); GR-3108-CORE; GR-3160-CORE; ATIS 0600319
ETSI 300 019; MIL-STD-167-1; MIL-STD-167-1A; MIL-STD-202 (Methods 201, 201A, 202, 202D, 203B, 204, 204D, 205, 212, 213, & 214); MIL-STD-740-2; MIL-STD-750, -781; MIL-STD-810 A, B, C, D, E (all changes), F (all notices), G, G(1), H, H(1) (Methods 514, 516, & 519); MIL-STD-883C, E(all notices), F, G, H, J(all changes), K(all changes), L (Methods 2002, 2005, 2007, & 2026); MIL-STD-1344 (Methods 2004, 2005); ANSI/IEEE 344, 382; ANSI/IEEE C37.98; ATIS 0600329; ASTM D999, D5276; ASTM D4169-05, -08, -09, -14, -16, -22, -23e; GR-63-CORE; GR-3108-CORE; GR-3160-CORE; GR-487-CORE; GR-2834-CORE; EN/IEC 60065, 60204-1; ETS EN 300 019; IEC 68-2-27, 68-2-34; IEC 60068; RTCA/DO-160B, C, D(all changes), E, F, G, G(1) (Sections 7 & 8)
CEI/IEC 60529:1989/AMD2:2013/COR1:2019; ISO 20653 IPX9K; ISTA Pre-shipment Test Procedures (1A, 1B, 1C, 1D, 1E, 1G, 1H, 2A, 2B, 2C, 2D, 2E, 3A, 3E, 3F, 3H, 5B, 7B, 7C, 7D, 6-series); ASTM D4169-05, -08, -09, -14, -16, -22, -23e; GR-63-CORE; MIL-STD-810 A, B, C, D, E (all changes), F (all notices), G, G(1), H, H(1) (Method 516); MIL-STD-810 A, B, C, D, E (all changes), F (all notices), G, G(1), H, H(1) (Method 521); RTCA/DO-160 B, C, D(all changes), E, F, G, G(1) (Section 24); BOX-SOP-ENV-005; RTCA/DO-160 B, C, D(all changes), E, F, G, G(1) (Section 7.3); MIL-STD-810 A, B, C, D, E (all changes), F (all notices), G, G(1), H, H(1) (Method 513.5); RTCA/DO-160 B, C, D(all changes), E, F, G, G(1) (Section 11); MIL-STD-810 A, B, C, D, E (all changes), F (all notices), G, G(1), H, H(1) (Method 504); MIL-STD-202 (Method 215); MIL-STD-810 (Method 505 Heat Load); MIL-STD-810 A, B, C, D, E (all changes), F (all notices), G, G(1), H, H(1) (Method 511.4); RTCA/DO-160 B, C, D(all changes), E, F, G, G(1) (Section 9); MIL-STD-750 (Methods 1001, 1011, & 1021); EN/IEC 60695-2-2; ATIS 0600307; ATIS 0600319; UL 1694
Read from the A2LA scope documents we downloaded on 2026-03-14 and 2026-10-27. Register refreshed 2026-11-20.
Scope as published by A2LA
9 lines
ISO/IEC 17025
Active214.14
The scope document we hold says it is valid until 2027-09-30.
ISO/IEC 17025
Active214.15
The scope document we hold says it is valid until 2027-09-30.
Location
Labs with overlapping accredited scope in United States
- Tektronix, Inc. - N. Billerica TestNorth Billerica, MA · ~22 kmA2LAShares 1 accredited test methodIEC 60068-2-1
- Green Mountain ElectromagneticsMiddlebury, VT · ~217 kmA2LAShares 1 accredited test methodIEC 60068-2-1
- Clark Dynamic Testing Laboratory, Inc.Jefferson Hills, PA · ~743 kmA2LAShares 1 accredited test methodIEC 60068-2-1
- APTIV WESTFIELD TESTWestfield, IN · ~1,251 kmA2LAShares 1 accredited test methodIEC 60068-2-1
- Austin ReliabilityAustin, TX · ~2,696 kmA2LAShares 1 accredited test methodIEC 60068-2-1
Accreditation data refreshed from the A2LA register on .