Registers refreshed 2026-11-08.See refresh dates
United States

Structural Integrity Associates, Inc. (SI)

11515 Vanstory Dr. Suite 125, NC 28078-6309, Hunterville, United States

Visit website
SWEDAC A012393-001SWEDAC a012393-001ISO/IEC 17025Register refreshed 2026-11-08

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
2
SWEDAC certificates
2
Site in our directory
1
SWEDAC accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 2 scope lines.

SWEDAC certificate A012393-001 · 1 line

This scope has not been split into individual lines yet. Below is the text of the scope document as published.

Ackrediteringens omfattning Provningslaboratorier enligt SS-EN ISO/IEC 17025:2018 Structural Integrity Associates, Inc. (SI) Huntersville Ackrediteringsnummer 2042 A012393-001 Materialprovning Oförstörande provning Mätprincip Metod Provtyp Kravspecifikation Fält Ultraljudsprovning Enligt procedur godkänd av ett kvalificeringsorgan godkänt av SSM Enligt procedur Enligt procedur godkänd av ett kvalificeringsorgan godkänt av SSM Ja Sida 1 (1) Bilaga 1 Beteckning Datum 2020-09-02 2019/2128

Extracted from the scope document; tables may not line up. View scope for the original.

SWEDAC certificate a012393-001 · 1 line

LineMethodMatrixRange
1-Metal
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Scope of accreditation Testing laboratory according to SS-EN ISO/IEC 17025:2018 Structural Integrity Associates, Inc. (SI) Huntersville Accreditation number 2042 A012393-001 Material testing Non-destructive testing Technique Method Material Requirement specification Field Ultrasonic Testing Qualified procedures by a qualification body approved by SSM According to procedure Qualified procedures by a qualification body approved by SSM Yes Page 1 (1) Appendix 1 Reference Date 2020-09-02 2019/2128
-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

11515 Vanstory Dr. Suite 125, Hunterville, NC 28078-6309, US

35.12990, -80.88197

Open in Maps

Accreditation data refreshed from the SWEDAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the SWEDAC entry linked above.